ABB
1SDA062885R1T7S 1250 PR332/P LI In=1250A 3p F F M (T7MSFB3AP000000XX)
T7S 1250 PR332/P LI In=1250A 3p F F M (T7MSFB3AP000000XX)
Moulded / Molded Case Circuit Breaker (MCCB) - ABB / SACE (Tmax T (IEC) series) - T7S 1250 PR332/P LI In=1250A 3p F F M - 3-poles (3P3d) - Rated current 1250A - Short circuit breaking capacity (Icu) 50kA (415Vac) - Electronic (PR332/P LI) trip unit
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
1SDA062885R1
Please add this item to cart to request a quote.
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Click on the colored tile to view a product selector for this product series:
1SDA062885R1ABB - Tmax T
Description
Moulded / Molded Case Circuit Breaker (MCCB) - ABB / SACE (Tmax T (IEC) series) - T7S 1250 PR332/P LI In=1250A 3p F F M - 3-poles (3P3d) - Rated current 1250A - Short circuit breaking capacity (Icu) 50kA (415Vac) - Electronic (PR332/P LI) trip unit
Specifications
Primary brand
ABB
Secondary brand
SACE
Main function
Moulded Case Circuit Breaker (MCCB)
Product series / family name
Tmax T (IEC)
Sub-range name
T7S complete breakers
Functions
Moulded / Molded Case Circuit Breaker (MCCB)
Circuit-breaker status (open/closed) (signalling via Modbus)
Protection parameters set (signalling via Modbus)
Load control parameters (signalling via Modbus)
Protections (L/I) (signalling via Modbus)
Undervoltage/overvoltage and residual voltage protection (timing and trip) (signalling via Modbus)
Reverse power protection (timing and trip) (signalling via Modbus)
Directional protection (timing and trip) (signalling via Modbus)
Underfrequency/overfrequency protection (timing and trip) (signalling via Modbus)
Phases rotation (signalling via Modbus)
Failed tripping under fault conditions (signalling via Modbus)
Record data of last trip (signalling via Modbus)
Status changes in circuit-breaker/protections and all alarms (signalling via Modbus)
Circuit-breaker status (open/closed) (signalling via Modbus)
Protection parameters set (signalling via Modbus)
Load control parameters (signalling via Modbus)
Protections (L/I) (signalling via Modbus)
Undervoltage/overvoltage and residual voltage protection (timing and trip) (signalling via Modbus)
Reverse power protection (timing and trip) (signalling via Modbus)
Directional protection (timing and trip) (signalling via Modbus)
Underfrequency/overfrequency protection (timing and trip) (signalling via Modbus)
Phases rotation (signalling via Modbus)
Failed tripping under fault conditions (signalling via Modbus)
Record data of last trip (signalling via Modbus)
Status changes in circuit-breaker/protections and all alarms (signalling via Modbus)
Poles
3-poles (3P3d)
Rated current
1250A
Trip current rating
1250 AT
Frame current rating
1250 AF
Rated operating voltage (Ue)
690 V
Rated Voltage (DC)
750Vdc
Rated voltage (AC)
690Vac
Rated impulse voltage (Uimp)
8 kV
Rated insulation voltage (Ui)
1000 V
Connection type
Ring-lug or bar connections
Ultimate short circuit current breaking capacity (Icu)
85kA (240Vac)
50kA (380Vac)
50kA (415Vac)
50kA (440Vac)
40kA (500Vac)
30kA (690Vac)
50kA (380Vac)
50kA (415Vac)
50kA (440Vac)
40kA (500Vac)
30kA (690Vac)
Short circuit withstand current (Icw)
20kA (1s)
Service short circuit current breaking capacity (Ics)
85kA (240Vac)
50kA (380Vac)
50kA (415Vac)
50kA (440Vac)
40kA (500Vac)
30kA (690Vac)
50kA (380Vac)
50kA (415Vac)
50kA (440Vac)
40kA (500Vac)
30kA (690Vac)
Service short circuit current breaking capacity as a percentage of Icu (Ics%)
(415Vac) 100 %
Trip unit type
Electronic
PR332/P LI
LI
Display = LCD
PR332/P LI
LI
Display = LCD
Protection functions
(L) Protection against overload
(I) Instantaneous protection against short-circuit
(OT) Protection against overtemperature of the trip unit (instantaneous trip)
(U) Unbalanced phase / phase loss
(I) Instantaneous protection against short-circuit
(OT) Protection against overtemperature of the trip unit (instantaneous trip)
(U) Unbalanced phase / phase loss
Protection settings
L - Protection against overload -- adjustable 0.14...1 x In (175A...1250A)
I - Instantaneous protection against short-circuit -- adjustable 1.5...15 x In (1875A...18750A)
I - Instantaneous protection against short-circuit -- adjustable 1.5...15 x In (1875A...18750A)
Measurement function
Phase currents
Neutral current
Ground current
Voltage (phase-phase/phase-neutral/residual)
Power (active/reactive/apparent)
Power factor
Frequency and peak factor
Energy (active/reactive/apparent)
Harmonic analysis
Total number of operations
Total number of trips
Number of trip tests
Number of manual operations
Number of separate trips for each protection function
Contact wear (%)
Neutral current
Ground current
Voltage (phase-phase/phase-neutral/residual)
Power (active/reactive/apparent)
Power factor
Frequency and peak factor
Energy (active/reactive/apparent)
Harmonic analysis
Total number of operations
Total number of trips
Number of trip tests
Number of manual operations
Number of separate trips for each protection function
Contact wear (%)
Operating mode
Stored energy closing/opening mechanism
Dimensions
H268mm x W210mm x D178mm
Power dissipation/losses
(1-pole) 47 W
Order code / Manufacturer SKU
T7S 1250 PR332/P LI In=1250A 3p F F M
T7MSFB3AP000000XX
1SDA062885R1
T7MSFB3AP000000XX
1SDA062885R1
Manufacturer product status
Commercialized
EAN code
8015644654344
UNSPSC code
39121616
UPC code
804325343763
Compliant with standard(s)
IEC 60947-2
EC directive "Low Voltage Directives" (LVD) no. 2006/95/CE (in replacement of 73/23/ CEE and subsequent amendments)
EC directive "Electromagnetic Compatibility Directive" (EMC) 2004/108/CE
IEC 60073
IEC 60417-2
IEC 60529
IEC 60068-2-30 (tropicalization)
IEC 60068-2-6 (resistance to shocks and vibrations)
IEC 60068-2-27 (resistance to shocks)
EC directive "Low Voltage Directives" (LVD) no. 2006/95/CE (in replacement of 73/23/ CEE and subsequent amendments)
EC directive "Electromagnetic Compatibility Directive" (EMC) 2004/108/CE
IEC 60073
IEC 60417-2
IEC 60529
IEC 60068-2-30 (tropicalization)
IEC 60068-2-6 (resistance to shocks and vibrations)
IEC 60068-2-27 (resistance to shocks)
Related Documents
Name | Last Update | Language |
---|---|---|
ABB - Tmax T Moulded Case Circuit Breakers - Catalogue.pdf | 02 Feb 2023 | English (US) |