1SDX145499R1T8L 2500 PR332/P LSIG In=2500A 3p F F + Acc
T8L 2500 PR332/P LSIG In=2500A 3p F F + Acc
Moulded / Molded Case Circuit Breaker (MCCB) with indicator - ABB / SACE (Tmax T (IEC) series) - T8L 2500 PR332/P LSIG In=2500A 3p F F + Acc - 3-poles (3P3d) - Rated current 2500A - Short circuit breaking capacity (Icu) 85kA (415Vac) - Electronic (PR332/P LSIG) trip unit
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
1SDX145499R1
Online Price
$41,383.77
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
1SDX145499R1ABB - Tmax T8 IEC
Description
Moulded / Molded Case Circuit Breaker (MCCB) with indicator - ABB / SACE (Tmax T (IEC) series) - T8L 2500 PR332/P LSIG In=2500A 3p F F + Acc - 3-poles (3P3d) - Rated current 2500A - Short circuit breaking capacity (Icu) 85kA (415Vac) - Electronic (PR332/P LSIG) trip unit
Specifications
Primary brand
ABB
Secondary brand
SACE
Main function
Moulded Case Circuit Breaker (MCCB)
Product series / family name
Tmax T (IEC)
Sub-range name
T8L complete breakers
Functions
Moulded / Molded Case Circuit Breaker (MCCB)
Design
indicator
Poles
3-poles (3P3d)
Rated current
2500A
Trip current rating
2500 AT
Frame current rating
2500 AF
Rated operating voltage (Ue)
690 V
Rated voltage (AC)
690Vac
Rated impulse voltage (Uimp)
12 kV
Rated insulation voltage (Ui)
1000 V
Connection type
Ring-lug or bar connections
Ultimate short circuit current breaking capacity (Icu)
85kA (220Vac)
85kA (230Vac)
85kA (380Vac)
85kA (415Vac)
85kA (440Vac)
65kA (500Vac)
50kA (690Vac)
85kA (230Vac)
85kA (380Vac)
85kA (415Vac)
85kA (440Vac)
65kA (500Vac)
50kA (690Vac)
Service short circuit current breaking capacity (Ics)
85kA (220Vac)
85kA (230Vac)
85kA (380Vac)
85kA (415Vac)
85kA (440Vac)
65kA (500Vac)
50kA (690Vac)
85kA (230Vac)
85kA (380Vac)
85kA (415Vac)
85kA (440Vac)
65kA (500Vac)
50kA (690Vac)
Service short circuit current breaking capacity as a percentage of Icu (Ics%)
(415Vac) 100 %
Trip unit type
Technology = Electronic
Series = PR332/P LSIG
Protection = LSIG
Display = LCD
Series = PR332/P LSIG
Protection = LSIG
Display = LCD
Protection functions
(L) Protection against overload
(S) Protection against short-circuit with time delay
(I) Instantaneous protection against short-circuit
(G) Protection against earth fault
(OT) Protection against overtemperature of the trip unit (instantaneous trip)
(U) Unbalanced phase / phase loss
(S) Protection against short-circuit with time delay
(I) Instantaneous protection against short-circuit
(G) Protection against earth fault
(OT) Protection against overtemperature of the trip unit (instantaneous trip)
(U) Unbalanced phase / phase loss
Protection settings
L - Protection against overload -- adjustable 0.14...1 x In (350A...2500A)
S - Protection against short-circuit with time delay -- adjustable 0.6...10 x In (1500A...25000A); with adjustable time trip curve
I - Instantaneous protection against short-circuit -- adjustable 1.5...15 x In (3750A...37500A)
G - Protection against earth fault -- adjustable 0.2...1 x In (0.1...0.8s time delay)
S - Protection against short-circuit with time delay -- adjustable 0.6...10 x In (1500A...25000A); with adjustable time trip curve
I - Instantaneous protection against short-circuit -- adjustable 1.5...15 x In (3750A...37500A)
G - Protection against earth fault -- adjustable 0.2...1 x In (0.1...0.8s time delay)
Measurement function
Phase currents
Neutral current
Ground current
Voltage (phase-phase/phase-neutral/residual)
Power (active/reactive/apparent)
Power factor
Frequency and peak factor
Energy (active/reactive/apparent)
Harmonic analysis
Total number of operations
Total number of trips
Number of trip tests
Number of manual operations
Number of separate trips for each protection function
Contact wear (%)
Neutral current
Ground current
Voltage (phase-phase/phase-neutral/residual)
Power (active/reactive/apparent)
Power factor
Frequency and peak factor
Energy (active/reactive/apparent)
Harmonic analysis
Total number of operations
Total number of trips
Number of trip tests
Number of manual operations
Number of separate trips for each protection function
Contact wear (%)
Operating mode
Stored energy closing/opening mechanism
Electrical durability (with load)
4000 operations
Mechanical durability (at no load)
15000 operations
Power dissipation/losses
(1-pole) 73 W
Order code / Manufacturer SKU
T8L 2500 PR332/P LSIG In=2500A 3p F F + Acc
Manufacturer product status
Commercialized
EAN code
8057558924991
Compliant with standard(s)
IEC 60947-2
Related Documents