Schneider Electric
BMECXM0100HCANopen X80Master hardened
CANopen X80Master hardened
Communication module - for severe environments (with conformal coating) - Schneider Electric / Modicon (Modicon X80 series) - with CANopen communication capability - backplane / rack mounting - with 1 x 9-pin D-Sub (male) connector - IP20 - Rated for -13...+158°F / -25...+70°C ambient
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
BMECXM0100H
Online Price
$3,937.50
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Schneider Electric - Modicon X80 communications modulesBMECXM0100H
Description
Communication module - for severe environments (with conformal coating) - Schneider Electric / Modicon (Modicon X80 series) - with CANopen communication capability - backplane / rack mounting - with 1 x 9-pin D-Sub (male) connector - IP20 - Rated for -13...+158°F / -25...+70°C ambient
Specifications
Primary brand
Schneider Electric
Secondary brand
Modicon
Main function
Communications unit
Product series / family name
Modicon X80
Sub-range name
Modicon X80 communication modules
Functions
Communication module
Design
for severe environments (with conformal coating)
Supply voltage (DC)
24Vdc (internally supplied via rack)
Connection type
1 x 9-pin D-Sub (male) connector
Communication protocol
CANopen
Mounting mode
backplane / rack mounting
Degree of protection
IP20
Ambient air temperature for operation
-13...+158°F / -25...+70 °C
Ambient air temperature for storage
-40...+185°F / -40...+85 °C
Humidity
10-95% (without condensation)
Chemical resistance
IEC/EN 60721-3-3 -- class 3C1; 3C2; 3C3; 3C4 (Concentrations H2S 9900PPB (parts per billion) /SO2 4800PPB / Cl2 200PPB)
IEC/EN 60068-2-52 -- salt mist Kb test severity level 2 (3 x 24-hour cycles; 5% NaCl 40°C/104°F; relative humidity 93%)
ISA S71.04 -- classes G1 to Gx concentrations (H2S 60PPB / SO2 350PPB / Cl2 1450PPB / NO2 12PPB)
Gas resistant class Gx conforming to ISA S71.04
Gas resistant class 3C4 conforming to IEC 60721-3-3
Dust resistant class 3S4 conforming to IEC 60721-3-3
Sand resistant class 3S4 conforming to IEC 60721-3-3
Salt resistant level 2 conforming to IEC 68252
Mold growth resistant class 3B2 conforming to IEC 60721-3-3
Fungal spore resistant class 3B2 conforming to IEC 60721-3-3
Hazardous location class I division 2
Resistant to harsh environment (conformal coated PCB)
IEC/EN 60068-2-52 -- salt mist Kb test severity level 2 (3 x 24-hour cycles; 5% NaCl 40°C/104°F; relative humidity 93%)
ISA S71.04 -- classes G1 to Gx concentrations (H2S 60PPB / SO2 350PPB / Cl2 1450PPB / NO2 12PPB)
Gas resistant class Gx conforming to ISA S71.04
Gas resistant class 3C4 conforming to IEC 60721-3-3
Dust resistant class 3S4 conforming to IEC 60721-3-3
Sand resistant class 3S4 conforming to IEC 60721-3-3
Salt resistant level 2 conforming to IEC 68252
Mold growth resistant class 3B2 conforming to IEC 60721-3-3
Fungal spore resistant class 3B2 conforming to IEC 60721-3-3
Hazardous location class I division 2
Resistant to harsh environment (conformal coated PCB)
Current consumption
70mA
Technical compatibility with
Modicon M580 PLCs
Order code / Manufacturer SKU
BMECXM0100H
Manufacturer product status
Commercialized
Compliant with standard(s)
CSA C22.2 No.61010-2-201
EN/IEC 61131-2
EN/IEC 61010-2-201
EN/IEC 61000-6-5
EN/IEC 61850-3
EN/IEC 60079-0
UL61010-2-201
IACS E10
RoHS directive 2011/65/EU
WEEE directive 2012/19/EU
CE
EAC
Merchant Navy
REACH regulations (EC No. 1907/2006)
For USA and Canada -- Hazardous location class I; division 2; groups A;B;C; and D
For European Union -- ATEX for atmosphere Zone 2 (gas) and Zone 22 (dust)
For United Kingdom -- UKEX for atmosphere Zone 2 (gas) and Zone 22 (dust)
For other countries -- IECEx for atmosphere Zone 2 (gas) and/or Zone 22 (dust)
IEC/EN61131-2; IEC60068-2-27 (Ea) - Shocks 30g; 11ms; 3 shocks/direction/axis
EN/IEC 61131-2
EN/IEC 61010-2-201
EN/IEC 61000-6-5
EN/IEC 61850-3
EN/IEC 60079-0
UL61010-2-201
IACS E10
RoHS directive 2011/65/EU
WEEE directive 2012/19/EU
CE
EAC
Merchant Navy
REACH regulations (EC No. 1907/2006)
For USA and Canada -- Hazardous location class I; division 2; groups A;B;C; and D
For European Union -- ATEX for atmosphere Zone 2 (gas) and Zone 22 (dust)
For United Kingdom -- UKEX for atmosphere Zone 2 (gas) and Zone 22 (dust)
For other countries -- IECEx for atmosphere Zone 2 (gas) and/or Zone 22 (dust)
IEC/EN61131-2; IEC60068-2-27 (Ea) - Shocks 30g; 11ms; 3 shocks/direction/axis
Benefits
The BMECXM0100 CANopen X80 master module is standard format (1 slot) and supports one CANopen port (SUB-D9 male connector)
The BMECXM0100 supports up to 63 slaves with a maximum process image size of 4 Kbytes IN/4 Kbytes OUT
Standardized baudrates between 20Kbaud and 1Mbd (20 Kbaud / 50 Kbaud / 125 Kbaud / 250 Kbaud / 500 Kbaud / 1 Mbd) are supported
The BMECXM0100 supports up to 63 slaves with a maximum process image size of 4 Kbytes IN/4 Kbytes OUT
Standardized baudrates between 20Kbaud and 1Mbd (20 Kbaud / 50 Kbaud / 125 Kbaud / 250 Kbaud / 500 Kbaud / 1 Mbd) are supported
Location of origin
Ireland (IE)
Related Documents
Name | Last Update | Language |
---|---|---|
Download official PDF datasheet for BMECXM0100H from Schneider Electric | 18 Jun 2021 | English (US) |
Schneider Electric - Modules platform - Modicon X80 - Catalog.pdf | 08 Jan 2023 | English (US) |