BMXSDI1602Discrete input module - 16 inputs - 24Vdc positive - Safety
Discrete input module - 16 inputs - 24Vdc positive - Safety
Safety DC digital input module - SIL3 / PLd Cat2 (1 input channel) and PLe Cat4 (2 inputs channels) - Schneider Electric / Modicon (Modicon X80 series) - 16I/Os [16DI (16 x digital inputs (Positive))] - Supply voltage 19-30Vdc (24Vdc nom.) - backplane / rack mounting - with 1 x 20-pin removable term. blck. (caged; screw or spring removable term.; sold separately) - IP20 - Red color - Rated for -13...+140°F / -25...+60°C ambient - IEC/EN61131-2 conformity type 3 - replaces 140SDI95300S
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
BMXSDI1602
Online Price
$1,750.00
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
BMXSDI1602Schneider Electric - Modicon X80 I/O modules
Description
Safety DC digital input module - SIL3 / PLd Cat2 (1 input channel) and PLe Cat4 (2 inputs channels) - Schneider Electric / Modicon (Modicon X80 series) - 16I/Os [16DI (16 x digital inputs (Positive))] - Supply voltage 19-30Vdc (24Vdc nom.) - backplane / rack mounting - with 1 x 20-pin removable term. blck. (caged; screw or spring removable term.; sold separately) - IP20 - Red color - Rated for -13...+140°F / -25...+60°C ambient - IEC/EN61131-2 conformity type 3 - replaces 140SDI95300S
Specifications
Primary brand
Schneider Electric
Secondary brand
Modicon
Main function
Safety I/O unit
Product series / family name
Modicon X80
Sub-range name
Modicon X80 I/O modules
Functions
Safety DC digital input module
Design
IEC/EN61131-2 conformity type 3
Supply voltage (DC)
19-30Vdc (24Vdc nom.)
Display
1 green LED (module operating; RUN)
1 green LED (per channel channel diagnostic)
1 red LED (module error; ERR)
1 red LED (module I/O)
1 green LED (per channel channel diagnostic)
1 red LED (module error; ERR)
1 red LED (module I/O)
Color
Red color
Connection type
1 x 20-pin removable term. blck. (caged; screw or spring removable term.; sold separately)
Mounting mode
backplane / rack mounting
Digital inputs
16 x digital inputs (Positive)
Degree of protection
IP20
Ambient air temperature for operation
-13...+140°F / -25...+60 °C
Ambient air temperature for storage
-40...+185°F / -40...+85 °C
Humidity
5-95% (at 131°F (55°C) without condensation)
Chemical resistance
Gas resistant class Gx
Gas resistant class 3C4
Dust resistant class 3S4
Sand resistant class 3S4
Salt resistant level 2
Mold growth resistant class 3B2
Fungal spore resistant class 3B2
Gas resistant class 3C4
Dust resistant class 3S4
Sand resistant class 3S4
Salt resistant level 2
Mold growth resistant class 3B2
Fungal spore resistant class 3B2
Current consumption
256mA (at 3.3Vdc)
100mA (at 24Vdc)
100mA (at 24Vdc)
Technical compatibility with
Modicon M580 PLCs
Power dissipation/losses
3.57 W
Order code / Manufacturer SKU
BMXSDI1602
Manufacturer product status
Commercialized
Replaces
140SDI95300S
Compliant with standard(s)
RoHS directive 2011/65/EU
WEEE directive 2012/19/EU
CE
EAC
Merchant Navy
REACH regulations (EC No. 1907/2006)
Meets or exceeds IEC60068-2 requirements -- Shocks 30g (vs IEC requirement 15g) / vibrations 3g (vs IEC requirement 1g)
WEEE directive 2012/19/EU
CE
EAC
Merchant Navy
REACH regulations (EC No. 1907/2006)
Meets or exceeds IEC60068-2 requirements -- Shocks 30g (vs IEC requirement 15g) / vibrations 3g (vs IEC requirement 1g)
Class
SIL3 / PLd Cat2 (1 input channel) and PLe Cat4 (2 inputs channels)
Benefits
Safety I/O modules can be used to connect the Safety PAC to sensors and actuators that are not part of the safety function loop
Each Safety I/O module incorporates a dedicated Safety processor
Safety I/O modules can be installed in the local backplane or in RIO drops
All Safety I/O modules support SIL3 standards according to IEC 61508. The assessment is indicated by the category (Cat) and performance level (PL)
Each Safety I/O module provides module and channel LED diagnostics on the frontface of the module
- The top four LEDs (Run / Err / I/O / Lck) indicate the module status
- The bottom rows of LEDs combine with the top four LEDs to indicate the state and health of each input or output channel
Each Safety I/O module incorporates a dedicated Safety processor
Safety I/O modules can be installed in the local backplane or in RIO drops
All Safety I/O modules support SIL3 standards according to IEC 61508. The assessment is indicated by the category (Cat) and performance level (PL)
Each Safety I/O module provides module and channel LED diagnostics on the frontface of the module
- The top four LEDs (Run / Err / I/O / Lck) indicate the module status
- The bottom rows of LEDs combine with the top four LEDs to indicate the state and health of each input or output channel
Location of origin
France (FR)
Related Documents
Name | Last Update | Language |
---|---|---|
Schneider Electric - Modules platform - Modicon X80 - Catalog.pdf | 08 Jan 2023 | English (US) |