PULS
CP10.121
AC/DC Power supply unit (PSU) / converter with ATEX approval + shutdown input - 20% power reserve - PULS (DIMENSION CP-series) - 12Vdc-15Vdc (adjustable) / 16A / 192W output - with screw-clamp connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-180Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc nom.)) - DIN rail mounting (39mm width) - equivalent to #CP10121
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
Brand
SKU
CP10.121
Online Price
$312.00
Discount
10.0%
Net Price
$280.80
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
CP10.121
Description
AC/DC Power supply unit (PSU) / converter with ATEX approval + shutdown input - 20% power reserve - PULS (DIMENSION CP-series) - 12Vdc-15Vdc (adjustable) / 16A / 192W output - with screw-clamp connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-180Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc nom.)) - DIN rail mounting (39mm width) - equivalent to #CP10121
Specifications
Primary brand
PULS
Main function
Power supply unit
Product series / family name
DIMENSION series
Sub-range name
CP-series
Functions
AC/DC Power supply unit (PSU) / converter
20% power reserve
20% power reserve
Design
ATEX approval
shutdown input
20% power reserve
DC-OK rly. contact output
shutdown input
20% power reserve
DC-OK rly. contact output
Supply voltage (AC)
85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)
80Vac turn-ON voltage
70Vac shutdown voltage (steady-state; no load)
55Vac shutdown voltage (dynamic value)
80Vac turn-ON voltage
70Vac shutdown voltage (steady-state; no load)
55Vac shutdown voltage (dynamic value)
Supply voltage (DC)
88Vdc-180Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc nom.)
Display
"DC-OK" LED
Type of network
Single-phase (1AC) or DC
Rated current
16A (at 12Vdc)
Rated power
192W
Output voltage (DC)
12Vdc-15Vdc (adjustable)
200mV turn-ON overshoot
200mV turn-ON overshoot
Hold time
50ms
Connection type
screw-clamp connections
Protection functions
output overvoltage protection (18.2Vdc typ. / 19Vdc max.)
Overload / short-circuit current -- 7.3A average (R.M.S.) current / min. 50A (typ. 55A) up to 12ms at load impedance <12mΩ
Series / parallel operation -- devices of the same type can be connected in series for higher output voltages / Devices can be paralleled to increase the output power. The output voltage shall be adjusted to the same value (+/-100mV) with the same load conditions on all devices (or the devices can be left with the factory settings). Devices can be paralleled for 1+1 redundancy to gain higher system availability using a redundancy module
Back-feeding loads max. 25V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Overload / short-circuit current -- 7.3A average (R.M.S.) current / min. 50A (typ. 55A) up to 12ms at load impedance <12mΩ
Series / parallel operation -- devices of the same type can be connected in series for higher output voltages / Devices can be paralleled to increase the output power. The output voltage shall be adjusted to the same value (+/-100mV) with the same load conditions on all devices (or the devices can be left with the factory settings). Devices can be paralleled for 1+1 redundancy to gain higher system availability using a redundancy module
Back-feeding loads max. 25V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Efficiency
0.943 (230Vac input)
0.928 (120Vac input)
0.921 (100Vac input)
0.928 (120Vac input)
0.921 (100Vac input)
Mounting mode
DIN rail mounting
Time delay
240-300ms start-up delay (100-230Vac input)
18ms rise time (nominal input; constant full current load; 0mF load capacitance)
35ms rise time (nominal input; constant full current load; 16mF load capacitance)
18ms rise time (nominal input; constant full current load; 0mF load capacitance)
35ms rise time (nominal input; constant full current load; 16mF load capacitance)
Dimensions
W39mm x H124mm x D117mm
Net Width (mm)
39 mm
Material
Aluminium housing
Ambient air temperature for operation
-25...+70 °C
Current consumption
11A peak max. inrush (at 230Vac input)
7A peak max. inrush (at 120Vac input)
7A peak max. inrush (at 120Vac input)
Power dissipation/losses
(230Vac input; full output load) 11.6 W
(120Vac input; full output load) 14.9 W
(120Vac input; full output load) 14.9 W
Power factor (cos phi)
(230Vac input) 0.96
(120Vac input) 0.99
(120Vac input) 0.99
Manufacturer product status
Commercialized
Equivalent to
CP10121
Capacitance
(output stage) 5350 μF
Compliant with standard(s)
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
Class I Div. 2 HazLoc
GL Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
Class I Div. 2 HazLoc
GL Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
Electrical durability
(at 40°C; 8A output; 1AC 120Vac input) 176000 hours
(at 40°C; 8A output; 1AC 230Vac input) 189000 hours
(at 25°C; 8A output; 1AC 120Vac input) 499000 hours
(at 25°C; 8A output; 1AC 230Vac input) 534000 hours
(at 40°C; 16A output; 1AC 120Vac input) 75000 hours
(at 40°C; 16A output; 1AC 230Vac input) 97000 hours
(at 25°C; 16A output; 1AC 120Vac input) 213000 hours
(at 25°C; 16A output; 1AC 230Vac input) 275000 hours
(at 40°C; 19.2A output; 1AC 120Vac input) 40000 hours
(at 40°C; 19.2A output; 1AC 230Vac input) 57000 hours
(at 25°C; 19.2A output; 1AC 120Vac input) 112000 hours
(at 25°C; 19.2A output; 1AC 230Vac input) 160000 hours
(at 40°C; 8A output; 1AC 230Vac input) 189000 hours
(at 25°C; 8A output; 1AC 120Vac input) 499000 hours
(at 25°C; 8A output; 1AC 230Vac input) 534000 hours
(at 40°C; 16A output; 1AC 120Vac input) 75000 hours
(at 40°C; 16A output; 1AC 230Vac input) 97000 hours
(at 25°C; 16A output; 1AC 120Vac input) 213000 hours
(at 25°C; 16A output; 1AC 230Vac input) 275000 hours
(at 40°C; 19.2A output; 1AC 120Vac input) 40000 hours
(at 40°C; 19.2A output; 1AC 230Vac input) 57000 hours
(at 25°C; 19.2A output; 1AC 120Vac input) 112000 hours
(at 25°C; 19.2A output; 1AC 230Vac input) 160000 hours
Benefits
AC 100-240V Wide-range input
Width only 39mm
Efficiency up to 94.3%
Excellent partial load efficiency
20% Output power reserve
Safe HiccupPLUS overload mode
Easy fuse breaking due to high overload peak current
Active power factor correction (PFC)
Minimal inrush current surge
Full power between -25°C and +60°C
Remote ON / OFF Function
DC-OK relay contact
3 Year warranty
The DIMENSION CP-Series units are high-end power supplies in a medium price range without compromising quality reliability and performance. The CP-Series is part of the DIMENSION power supply family. The most outstanding features of CP10 are the high efficiency advanced inrush current limitation active PFC and the wide operational temperature range. The CP-Series includes all the essential basic functions. The devices have a power reserve of 20% included which may even be used continuously at temperatures up to +45°C. Additionally the CP10 can deliver 3 times the nominal output current for at least 12ms which helps to trip fuses on faulty output branches. High immunity to transients and power surges as well as low electromagnetic emission a shutdown input a DC-OK relay contact and a large international approval package for a variety of applications makes this unit suitable for nearly every situation.
Width only 39mm
Efficiency up to 94.3%
Excellent partial load efficiency
20% Output power reserve
Safe HiccupPLUS overload mode
Easy fuse breaking due to high overload peak current
Active power factor correction (PFC)
Minimal inrush current surge
Full power between -25°C and +60°C
Remote ON / OFF Function
DC-OK relay contact
3 Year warranty
The DIMENSION CP-Series units are high-end power supplies in a medium price range without compromising quality reliability and performance. The CP-Series is part of the DIMENSION power supply family. The most outstanding features of CP10 are the high efficiency advanced inrush current limitation active PFC and the wide operational temperature range. The CP-Series includes all the essential basic functions. The devices have a power reserve of 20% included which may even be used continuously at temperatures up to +45°C. Additionally the CP10 can deliver 3 times the nominal output current for at least 12ms which helps to trip fuses on faulty output branches. High immunity to transients and power surges as well as low electromagnetic emission a shutdown input a DC-OK relay contact and a large international approval package for a variety of applications makes this unit suitable for nearly every situation.
Ripple
50mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
607000h (at +40°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
690000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
1056000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
1185000h (at +25°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
249000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
278000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
337000h (at +25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
381000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
55000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
64000h (at +40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
71000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
83000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
690000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
1056000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
1185000h (at +25°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
249000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
278000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
337000h (at +25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
381000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
55000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
64000h (at +40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
71000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
83000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - CP10-121 - Datasheet.pdf | 01 Oct 2021 | English (US) |