PULS
CP20.241-S2
AC/DC Power supply unit (PSU) / converter - 20% power reserve - PULS (DIMENSION CP-series) - 24Vdc-28Vdc (adjustable) / 20A / 480W output - with push-in spring connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-180Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc nom.)) - DIN rail mounting (48mm width) - equivalent to #CP20241S2
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
CP20.241-S2
Online Price
$432.00
Discount
10.0%
Net Price
$388.80
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
CP20.241-S2
Description
AC/DC Power supply unit (PSU) / converter - 20% power reserve - PULS (DIMENSION CP-series) - 24Vdc-28Vdc (adjustable) / 20A / 480W output - with push-in spring connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-180Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc nom.)) - DIN rail mounting (48mm width) - equivalent to #CP20241S2
Specifications
Primary brand
PULS
Main function
Power supply unit
Product series / family name
DIMENSION series
Sub-range name
CP-series
Functions
AC/DC Power supply unit (PSU) / converter
20% power reserve
20% power reserve
Design
20% power reserve
DC-OK rly. contact output
DC-OK rly. contact output
Supply voltage (AC)
85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)
82Vac turn-ON voltage
72Vac shutdown voltage
82Vac turn-ON voltage
72Vac shutdown voltage
Supply voltage (DC)
88Vdc-180Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc nom.)
Display
"DC-OK" LED
Type of network
Single-phase (1AC) or DC
Rated current
20A (at 24Vdc)
Rated power
480W
Output voltage (DC)
24Vdc-28Vdc (adjustable)
500mV turn-ON overshoot
500mV turn-ON overshoot
Hold time
32ms (buffer time at 120/230Vac input)
Connection type
push-in spring connections
Protection functions
output overvoltage protection (30.5Vdc typ. / 32Vdc max.)
Overload / short-circuit current -- 9.8A max. (R.M.S.) current / (typ. 29A) intermitted current peak for typ. 1s at load impedance 10mΩ
Series / parallel operation -- devices of the same type can be connected in series for higher output voltages / Devices can be paralleled to increase the output power. The output voltage shall be adjusted to the same value (+/-100mV) with the same load conditions on all devices (or the devices can be left with the factory settings). Devices can be paralleled for 1+1 redundancy to gain higher system availability using a redundancy module
Back-feeding loads max. 35V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Overload / short-circuit current -- 9.8A max. (R.M.S.) current / (typ. 29A) intermitted current peak for typ. 1s at load impedance 10mΩ
Series / parallel operation -- devices of the same type can be connected in series for higher output voltages / Devices can be paralleled to increase the output power. The output voltage shall be adjusted to the same value (+/-100mV) with the same load conditions on all devices (or the devices can be left with the factory settings). Devices can be paralleled for 1+1 redundancy to gain higher system availability using a redundancy module
Back-feeding loads max. 35V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Efficiency
0.956 (230Vac input)
0.942 (120Vac input)
0.936 (100Vac input)
0.942 (120Vac input)
0.936 (100Vac input)
Mounting mode
DIN rail mounting
Time delay
450ms start-up delay (100-230Vac input)
145ms rise time (nominal input; constant full current load; 0mF load capacitance)
160ms rise time (nominal input; constant full current load; 20mF load capacitance)
145ms rise time (nominal input; constant full current load; 0mF load capacitance)
160ms rise time (nominal input; constant full current load; 20mF load capacitance)
Dimensions
W48mm x H124mm x D127mm
Net Width (mm)
48 mm
Material
Aluminium housing
Ambient air temperature for operation
-25...+70 °C
Current consumption
11A peak max. inrush (at 230Vac input)
7A peak max. inrush (at 120Vac input)
7A peak max. inrush (at 120Vac input)
Power dissipation/losses
(230Vac input; full output load) 22.1 W
(120Vac input; full output load) 29.6 W
(120Vac input; full output load) 29.6 W
Power factor (cos phi)
(230Vac input) 0.98
(120Vac input) 0.996
(120Vac input) 0.996
Manufacturer product status
Commercialized
Equivalent to
CP20241S2
Capacitance
(output stage) 8500 μF
Electrical durability
(at 40°C; 10A output; 1AC 120Vac input) 149000 hours
(at 40°C; 10A output; 1AC 230Vac input) 173000 hours
(at 25°C; 10A output; 1AC 120Vac input) 422000 hours
(at 25°C; 10A output; 1AC 230Vac input) 488000 hours
(at 40°C; 20A output; 1AC 120Vac input) 60000 hours
(at 40°C; 20A output; 1AC 230Vac input) 94000 hours
(at 25°C; 20A output; 1AC 120Vac input) 169000 hours
(at 25°C; 20A output; 1AC 230Vac input) 265000 hours
(at 40°C; 24A output; 1AC 120Vac input) 31000 hours
(at 40°C; 24A output; 1AC 230Vac input) 54000 hours
(at 25°C; 24A output; 1AC 120Vac input) 88000 hours
(at 25°C; 24A output; 1AC 230Vac input) 152000 hours
(at 40°C; 10A output; 1AC 230Vac input) 173000 hours
(at 25°C; 10A output; 1AC 120Vac input) 422000 hours
(at 25°C; 10A output; 1AC 230Vac input) 488000 hours
(at 40°C; 20A output; 1AC 120Vac input) 60000 hours
(at 40°C; 20A output; 1AC 230Vac input) 94000 hours
(at 25°C; 20A output; 1AC 120Vac input) 169000 hours
(at 25°C; 20A output; 1AC 230Vac input) 265000 hours
(at 40°C; 24A output; 1AC 120Vac input) 31000 hours
(at 40°C; 24A output; 1AC 230Vac input) 54000 hours
(at 25°C; 24A output; 1AC 120Vac input) 88000 hours
(at 25°C; 24A output; 1AC 230Vac input) 152000 hours
Benefits
AC 100-240V Wide-range input
Width only 48mm
Efficiency up to 95.6%
Excellent partial load efficiency
20% Output power reserve
Easy fuse breaking - 3 times nominal current for 12ms
Safe HiccupPLUS overload mode
Active power factor correction (PFC)
Minimal inrush current surge
Full power between -25°C and +60°C
DC-OK relay contact
Current sharing feature for parallel use
3 Year warranty
The Dimension CP-Series are cost optimized power supplies without compromising quality / reliability / performance.
The most outstanding features of the CP20 series are the high efficiency; electronic inrush current limitation; active PFC; wide operational temperature range and the extraordinary small size.
The CP20.242 features an enhanced DC input voltage range.
The devices have a power reserve of 20% included; which may even be used continuously up to +45°C.
High immunity to transients and power surges as well as low electromagnetic emission; a DC-OK relay contact and a large international approval package make this unit suitable for nearly every situation.
Width only 48mm
Efficiency up to 95.6%
Excellent partial load efficiency
20% Output power reserve
Easy fuse breaking - 3 times nominal current for 12ms
Safe HiccupPLUS overload mode
Active power factor correction (PFC)
Minimal inrush current surge
Full power between -25°C and +60°C
DC-OK relay contact
Current sharing feature for parallel use
3 Year warranty
The Dimension CP-Series are cost optimized power supplies without compromising quality / reliability / performance.
The most outstanding features of the CP20 series are the high efficiency; electronic inrush current limitation; active PFC; wide operational temperature range and the extraordinary small size.
The CP20.242 features an enhanced DC input voltage range.
The devices have a power reserve of 20% included; which may even be used continuously up to +45°C.
High immunity to transients and power surges as well as low electromagnetic emission; a DC-OK relay contact and a large international approval package make this unit suitable for nearly every situation.
Ripple
50mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
445000h (at +40°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
191000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
42000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
832000h (at +25°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
263000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
55000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
590000h (at +40°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
226000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
50000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
1060000h (at +25°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
313000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
67000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
191000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
42000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
832000h (at +25°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
263000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
55000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
590000h (at +40°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
226000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
50000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
1060000h (at +25°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
313000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
67000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - CP20-241-S2 - Datasheet.pdf | 01 Oct 2021 | English (US) |