Turck
FCS-M18-AP8X6870704
6870704
Instrumentation insertion probe flow monitor sensor / switch - Turck (FCS series) - model #6870704 - Measuring range 50cm/s...15m/s (air) - M18 partially threaded barrel - 2m / 6.5ft cable terminated with bare end flying leads + M18 threaded male process port - 1 x digital output (20-30Vdc; PNP) - Nickel-plated brass housing - supply voltage 19.2-28.8Vdc (24Vdc nom.) - IP67 - Rated for 145psi / 10bar fluid circuits - Rated for 0°C...+60°C ambient - technically compatible with Air medium / Inert gases medium - equivalent to FCSM18AP8X
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
FCS-M18-AP8X
Online Price
$304.90
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
FCS-M18-AP8XTurck - FCS
Description
Instrumentation insertion probe flow monitor sensor / switch - Turck (FCS series) - model #6870704 - Measuring range 50cm/s...15m/s (air) - M18 partially threaded barrel - 2m / 6.5ft cable terminated with bare end flying leads + M18 threaded male process port - 1 x digital output (20-30Vdc; PNP) - Nickel-plated brass housing - supply voltage 19.2-28.8Vdc (24Vdc nom.) - IP67 - Rated for 145psi / 10bar fluid circuits - Rated for 0°C...+60°C ambient - technically compatible with Air medium / Inert gases medium - equivalent to FCSM18AP8X
Specifications
Primary brand
Turck
Main function
Sensor (Flow)
Product series / family name
Sensors > Flow sensors
Sub-range name
FCS series
Functions
Instrumentation insertion probe flow monitor sensor / switch
Supply voltage (DC)
19.2-28.8Vdc (24Vdc nom.)
Flow
50cm/s...15m/s (air)
Pressure
10bar
145psi
145psi
Temperature
-10°C...+70°C medium
Shape
M18 partially threaded barrel
Connection type
Pre-wired with 2m / 6.5ft cable terminated with bare end flying leads
M18 threaded male process port
M18 threaded male process port
Protection functions
Short-circuit (pulsed)
Reverse polarity
Reverse polarity
Digital outputs
1 x digital output (20-30Vdc; PNP)
Response time
(startup) 20-40 s
(normal operation) 1-5 s
(normal operation) 1-5 s
Degree of protection
IP67
Material
Nickel-plated brass housing
Ambient air temperature for operation
0°C...+60 °C
Current consumption
70mA / 0.07A
Technical compatibility with
Air medium
Inert gases medium
Inert gases medium
eClass code
27273190
Control circuit rated current
200mA / 0.2 A
Order code / Manufacturer SKU
FCS-M18-AP8X
6870704
6870704
Manufacturer product status
Commercialized
Equivalent to
FCSM18AP8X
EAN code
4047101175080
Compliant with standard(s)
UL
Benefits
The temperature gradient of a fluid indicates the change in fluid temperature within a specified time (unit of measure °C/°F/min
The monitor has the ability to compensate for sudden thermal shifts within the specified extremes
The temperature gradient for TURCK flow monitors is 4°C/second which is 15 times higher than standard flow devices
The monitor has the ability to compensate for sudden thermal shifts within the specified extremes
The temperature gradient for TURCK flow monitors is 4°C/second which is 15 times higher than standard flow devices
Location of origin
DE
Length (m)
(cable) 2 m
Application type
Weld tip protection
Pump run dry protection
Stamping press lubrication oil monitoring
Pump run dry protection
Stamping press lubrication oil monitoring
Related Documents
Name | Last Update | Language |
---|---|---|
Turck - Instrumentation sensors - Catalogue.pdf | 19 Mar 2023 | English (US) |