ABB
GJL1311903R8104VB7-30-10-F-84
VB7-30-10-F-84
Mini magnetic contactors reversing assembly - ABB (VB7 series) - VB7-30-10-F-84 - 2 x 3-poles (2x3P) - Reversing (REV) / FVR (Full-Voltage Reversing) - Rated current 20A (AC-1) - Control coil voltage 110Vac-127Vac (40-450Hz) - with 1NO aux. contact - Flat pin / Faston connections - Mounting on plate
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
GJL1311903R8104
Online Price
$119.89
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
ABB - VB7 series mini contactorsGJL1311903R8104
Description
Mini magnetic contactors reversing assembly - ABB (VB7 series) - VB7-30-10-F-84 - 2 x 3-poles (2x3P) - Reversing (REV) / FVR (Full-Voltage Reversing) - Rated current 20A (AC-1) - Control coil voltage 110Vac-127Vac (40-450Hz) - with 1NO aux. contact - Flat pin / Faston connections - Mounting on plate
Specifications
Primary brand
ABB
Main function
Contactor
Product series / family name
VB7 series
Sub-range name
VB7 contactors
Functions
Mini magnetic contactors reversing assembly
Poles
2 x 3-poles (2x3P)
Rated current
20A (380-400Vac; 40°C; AC-1)
16A (380-400Vac; 55°C; AC-1)
6A (690Vac; 40°C; AC-1)
6A (690Vac; 55°C; AC-1)
4A (24-120Vac; AC-15)
4A (220-240Vac; AC-15)
3A (380-400Vac; AC-15)
2A (500Vac; AC-15)
13.8A (115Vac; UL/CSA FLA; single-phase)
7.8A (200Vac; UL/CSA FLA; 3-phase)
9.6A (220-240Vac; UL/CSA FLA; 3-phase)
10A (230Vac; UL/CSA FLA; single-phase)
7.6A (440-480Vac; UL/CSA FLA; 3-phase)
6.1A (550-600Vac; UL/CSA FLA; 3-phase)
16A (380-400Vac; 55°C; AC-1)
6A (690Vac; 40°C; AC-1)
6A (690Vac; 55°C; AC-1)
4A (24-120Vac; AC-15)
4A (220-240Vac; AC-15)
3A (380-400Vac; AC-15)
2A (500Vac; AC-15)
13.8A (115Vac; UL/CSA FLA; single-phase)
7.8A (200Vac; UL/CSA FLA; 3-phase)
9.6A (220-240Vac; UL/CSA FLA; 3-phase)
10A (230Vac; UL/CSA FLA; single-phase)
7.6A (440-480Vac; UL/CSA FLA; 3-phase)
6.1A (550-600Vac; UL/CSA FLA; 3-phase)
Rated active power (kW)
3kW (220-240Vac; AC-3)
5.5kW (400-440Vac; AC-3)
5.5kW (500Vac; AC-3)
3kW (690Vac; AC-3)
5.5kW (400-440Vac; AC-3)
5.5kW (500Vac; AC-3)
3kW (690Vac; AC-3)
Rated power (HP)
3HP (220-240Vac; 3-phase; UL/CSA)
5HP (440-480Vac; 3-phase; UL/CSA)
5HP (550Vac-600Vac; 3-phase; UL/CSA)
5HP (440-480Vac; 3-phase; UL/CSA)
5HP (550Vac-600Vac; 3-phase; UL/CSA)
Rated operating voltage (Ue)
690 V
Rated impulse voltage (Uimp)
6 kV
Rated insulation voltage (Ui)
(IEC/VDE) 690 V
(UL/CSA) 600 V
(UL/CSA) 600 V
Connection type
Flat pin / Faston connections
Control Voltage (AC)
110Vac-127Vac (40-450Hz)
Mounting mode
Mounting on plate
Normally Open (NO) auxliary contacts
1 NO contacts
Normally Closed (NC) auxiliary contacts
0 NC contacts
Net Height (mm)
57.5 mm
Net Width (mm)
96.5 mm
Net Depth (mm)
46.5 mm
Current consumption
3.5VA inrush (coil)
3.5VA holding (coil)
3.5VA holding (coil)
Application type
Reversing (REV)
FVR (Full-Voltage Reversing)
FVR (Full-Voltage Reversing)
Order code / Manufacturer SKU
VB7-30-10-F-84
Manufacturer product status
Commercialized
Equivalent to
VB73010F84
EAN code
4013614191305
Compliant with standard(s)
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60529
IEC/EN 60947-4-1
IEC/EN 60529
Benefits
VB6 and VB7 3-pole compact design reversing contactors are space optimized control products mainly used for switching resistive or motor loads up to 690 V AC.
These reversing contactors are designed with
- built-in mechanical interlock. The coils must be mutually interlocked electrically and coils must be deenergised for 50 ms at least to prevent phase to phase short circuit on the arc
- control circuit AC operated
- low coil consumption (3.5 VA at pull-in and at holding)
- hum-free coil
- no auxiliary contact block permitted for mounting
- designed for soldering on PCB boards
These reversing contactors are designed with
- built-in mechanical interlock. The coils must be mutually interlocked electrically and coils must be deenergised for 50 ms at least to prevent phase to phase short circuit on the arc
- control circuit AC operated
- low coil consumption (3.5 VA at pull-in and at holding)
- hum-free coil
- no auxiliary contact block permitted for mounting
- designed for soldering on PCB boards
Operating rate
(AC-1) 300 Cycles/hour
(AC-3) 600 Cycles/hour
(AC-15) 600 Cycles/hour
(DC-1) 600 Cycles/hour
(DC-13) 600 Cycles/hour
(DC-3) 600 Cycles/hour
(AC-3) 600 Cycles/hour
(AC-15) 600 Cycles/hour
(DC-1) 600 Cycles/hour
(DC-13) 600 Cycles/hour
(DC-3) 600 Cycles/hour
Related Documents
Name | Last Update | Language |
---|---|---|
ABB - B6 BC6 B7 BC7 mini contactors - Catalog.pdf | 12 Dec 2021 | English (US) |
ABB - B6 BC6 series - Datasheet.pdf | 12 Dec 2021 | English (US) |
ABB - Contactors - Catalog.pdf | 13 Oct 2022 | English (US) |