Eaton
HCX01512BA
Enclosed clean power Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter dedicated to HVAC control - Eaton / Cutler-Hammer (HCX) - Rated input voltage (3-phase (3P)) 230Vac - Rated output current 42A (Low overload IL) - Rated power 11kW (Low overload IL) / 15HP (Low overload IL) - Frame size 6 - UL type 1 / NEMA 1 - with 12-pulse supply - with Brake chopper
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
HCX01512BA
Please add this item to cart to request a quote.
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Eaton - HCXHCX01512BA
Description
Enclosed clean power Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter dedicated to HVAC control - Eaton / Cutler-Hammer (HCX) - Rated input voltage (3-phase (3P)) 230Vac - Rated output current 42A (Low overload IL) - Rated power 11kW (Low overload IL) / 15HP (Low overload IL) - Frame size 6 - UL type 1 / NEMA 1 - with 12-pulse supply - with Brake chopper
Specifications
Primary brand
Eaton
Secondary brand
Cutler-Hammer
Main function
Variable Speed / Frequency Drive (VSD/VFD) / Inverter
Product series / family name
HCX
Functions
Enclosed clean power Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter dedicated to HVAC control
Brake chopper
Brake chopper
Supply voltage (AC)
230Vac
Type of network
3-phase input (3P)
Rated current
42A (Low overload IL)
Rated active power (kW)
11kW (Low overload IL)
Rated power (HP)
15HP (Low overload IL)
Protection functions
Overcurrent
Overvoltage
Undervoltage
Earth fault
Input phase supervision
Motor phase supervision
Overtemperature
Motor overload
Motor stall
Motor underload
Short-circuit
Overvoltage
Undervoltage
Earth fault
Input phase supervision
Motor phase supervision
Overtemperature
Motor overload
Motor stall
Motor underload
Short-circuit
Operating mode
Frequency control (V/f)
Open loop; Sensorless vector control
Open loop; Sensorless vector control
Digital inputs
6 x digital inputs (programmable)
Digital outputs
2 x digital outputs (SPDT Single Pole Double Throw contact type)
1 x digital output (Open collector)
1 x digital output (Open collector)
Analog inputs
2 x analog inputs (0-20mA / 4-20mA / 0-10V DC)
Analog outputs
1 x analog output (0-20mA)
Degree of protection
UL type 1
NEMA 1
NEMA 1
Ambient air temperature for operation
-10...+40 °C
Ambient air temperature for storage
-40...+70 °C
Technology used in component
12-pulse supply
Application type
HVAC control applications
Manufacturer product status
Commercialized
Compliant with standard(s)
IEC 61800-2
EN 61800-3
UL 508C
CE
EN 61800-3
UL 508C
CE
Benefits
Robust design proven 500000 hours MTBF
Integrated 3% line reactors standard on drives from FR4 through FR9
Simplified operating menu allows for typical programming changes; while programming mode provides control of everything
Quick Start Wizard built into the programming of the drive ensures a smooth start-up
Keypad can display up to three monitored parameters simultaneously
LOCAL/REMOTE operation from keypad
Copy/paste function allows transfer of parameter settings from one drive to the next
The SVX can be flexibly adapted to a variety of needs using our pre installed “Seven in One” precision application programs consisting of - Basic; Standard; Local/remote; Multi step speed control; PID control; Multi-purpose control; Pump and fan control with auto change
Additional I/O and communication cards provide plug and play functionality
I/O connections with simple quick connection terminals
Hand-held auxiliary 24 V power supply allows programming/monitoring of control module without applying full power to the drive
Control logic can be powered from an external auxiliary control panel; internal drive functions and fieldbus if necessary
Standard option board configuration includes an A9 I/O board and an A2 relay output board installed in slots A and B
Integrated 3% line reactors standard on drives from FR4 through FR9
Simplified operating menu allows for typical programming changes; while programming mode provides control of everything
Quick Start Wizard built into the programming of the drive ensures a smooth start-up
Keypad can display up to three monitored parameters simultaneously
LOCAL/REMOTE operation from keypad
Copy/paste function allows transfer of parameter settings from one drive to the next
The SVX can be flexibly adapted to a variety of needs using our pre installed “Seven in One” precision application programs consisting of - Basic; Standard; Local/remote; Multi step speed control; PID control; Multi-purpose control; Pump and fan control with auto change
Additional I/O and communication cards provide plug and play functionality
I/O connections with simple quick connection terminals
Hand-held auxiliary 24 V power supply allows programming/monitoring of control module without applying full power to the drive
Control logic can be powered from an external auxiliary control panel; internal drive functions and fieldbus if necessary
Standard option board configuration includes an A9 I/O board and an A2 relay output board installed in slots A and B
Related Documents
Name | Last Update | Language |
---|---|---|