Cooper Bussmann
KRP-C-2200SP
Low-Voltage (LV) time-delay current-limiting bolt-on fuse - Class L - Eaton / Cooper Bussmann (Low-Peak bolt-on type fuses) - Rated current 2200A - Rated voltage 600Vac / 300Vdc - Short circuit breaking rating 300kA (RMS symmetrical) - order code #KRP-C-2200SP
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
KRP-C-2200SP
Online Price
$13,067.56
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
KRP-C-2200SPEaton / Cooper Bussmann - Low-Voltage (LV) branch circuit Low-Peak bolt-on type fuses KRP-C-SP series
Description
Low-Voltage (LV) time-delay current-limiting bolt-on fuse - Class L - Eaton / Cooper Bussmann (Low-Peak bolt-on type fuses) - Rated current 2200A - Rated voltage 600Vac / 300Vdc - Short circuit breaking rating 300kA (RMS symmetrical) - order code #KRP-C-2200SP
Specifications
Primary brand
Eaton
Secondary brand
Cooper Bussmann
Main function
Fuse
Product series / family name
LV branch circuit fuses
Sub-range name
Low-Peak bolt-on type fuses
Functions
Low-Voltage (LV) time-delay current-limiting bolt-on fuse
Design
Class L
Rated current
2200A
Rated Voltage (DC)
300Vdc
Rated voltage (AC)
600Vac
Short circuit breaking rating
300kA (RMS symmetrical)
100kA (DC)
100kA (DC)
Technical compatibility with
large distribution switchboards
power panelboards
large machinery disconnects
power panelboards
large machinery disconnects
Order code / Manufacturer SKU
KRP-C-2200SP
Manufacturer product status
Commercialized
UPC code
051712691734
Compliant with standard(s)
UL Listed 248-10 Guide JFHR File E56412
CSA Certified Class 1422-02 File 53787; Class L per CSA C22.2 No. 248.10
RoHS compliant
RoHS 2011/65/EU compliant
CE
CSA Certified Class 1422-02 File 53787; Class L per CSA C22.2 No. 248.10
RoHS compliant
RoHS 2011/65/EU compliant
CE
Benefits
Time-delay of 4 seconds at 5 times rating allows closer sizing on large motor loads combined with Class L current limitation
Selective coordination ratio of 2/1 (within Low-Peak fuse family) prevents electrical shutdowns from extending beyond the failed circuit
Interrupting rating of 300kA RMS symmetrical provides adequate ratings without obsolescence for all electrical systems; big or small
Quality construction; using high-grade materials; provides lower watts loss and operating temperatures with superior arc quenching during current-limiting action
Selective coordination ratio of 2/1 (within Low-Peak fuse family) prevents electrical shutdowns from extending beyond the failed circuit
Interrupting rating of 300kA RMS symmetrical provides adequate ratings without obsolescence for all electrical systems; big or small
Quality construction; using high-grade materials; provides lower watts loss and operating temperatures with superior arc quenching during current-limiting action
Related Documents
Name | Last Update | Language |
---|---|---|
Eaton - Bussmann series solutions - Volume 4C Circuit Protection - Catalog.pdf | 25 Jul 2021 | English (US) |
Eaton-Cooper-Bussmann-KRP-C-SP-current-limiting-curve.jpg | 25 Jul 2021 | English (US) |
Eaton-Cooper-Bussmann-KRP-C-SP-fuse-curve.jpg | 25 Jul 2021 | English (US) |