Eaton
MMX32AA4D8F0-0
Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter - Eaton / Cutler-Hammer (M-Max) - Rated input voltage (3-phase (3P)) 200Vac-240Vac - Rated output current 4.8A (Low overload IL) - Rated power 1.1kW (Low overload IL) / 1.5HP (Low overload IL) - Frame size FS2 - IP20 - with EMC filter category C2 / C4 / C4 (class H) - with RS-485 / Modbus communication capability
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
MMX32AA4D8F0-0
Please add this item to cart to request a quote.
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Eaton - M-MaxMMX32AA4D8F0-0
Description
Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter - Eaton / Cutler-Hammer (M-Max) - Rated input voltage (3-phase (3P)) 200Vac-240Vac - Rated output current 4.8A (Low overload IL) - Rated power 1.1kW (Low overload IL) / 1.5HP (Low overload IL) - Frame size FS2 - IP20 - with EMC filter category C2 / C4 / C4 (class H) - with RS-485 / Modbus communication capability
Specifications
Primary brand
Eaton
Secondary brand
Cutler-Hammer
Main function
Variable Speed / Frequency Drive (VSD/VFD) / Inverter
Product series / family name
M-Max
Network frequency
(input) 45-66 Hz
(output) 0-320 Hz
(output) 0-320 Hz
Functions
Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter
Application macros - basic; pump; fan and high load (hoist)
Programmable start/stop and reverse signal logic (sinking or sourcing)
Reference scaling
Programmable start and stop functions
DC-brake at start and stop
Programmable V/Hz curve
Adjustable switching frequency
Autorestart function after fault
Protections and supervisions (all fully programmable; off; warning; fault)
Current signal input fault
External fault
Fieldbus communication
Eight preset speeds
Analog input range selection; signal scaling and filtering
PID controller
Skip frequencies
Application macros - basic; pump; fan and high load (hoist)
Programmable start/stop and reverse signal logic (sinking or sourcing)
Reference scaling
Programmable start and stop functions
DC-brake at start and stop
Programmable V/Hz curve
Adjustable switching frequency
Autorestart function after fault
Protections and supervisions (all fully programmable; off; warning; fault)
Current signal input fault
External fault
Fieldbus communication
Eight preset speeds
Analog input range selection; signal scaling and filtering
PID controller
Skip frequencies
Supply voltage (AC)
200Vac-240Vac
Type of network
3-phase input (3P)
Rated current
4.8A (Low overload IL; 100% continuous current)
6.8A (Low overload IL; nominal input current)
6.8A (Low overload IL; nominal input current)
Rated active power (kW)
1.1kW (Low overload IL)
Rated power (HP)
1.5HP (Low overload IL)
Protection functions
Overcurrent
Overvoltage
Undervoltage
Ground fault
Overtemperature
Motor overload
Motor stall
Motor underload
Short-circuit
Overvoltage
Undervoltage
Ground fault
Overtemperature
Motor overload
Motor stall
Motor underload
Short-circuit
Communication protocol
RS-485
Modbus
Modbus
Operating mode
Frequency control (V/f)
Open loop; Sensorless vector control
Open loop; Sensorless vector control
Digital inputs
1 x digital input (FWD)
1 x digital input (REV)
1 x digital input (Preset Speed)
1 x digital input (Preset Speed B1)
1 x digital input (Fault reset)
1 x digital input (Disable PL control)
1 x digital input (REV)
1 x digital input (Preset Speed)
1 x digital input (Preset Speed B1)
1 x digital input (Fault reset)
1 x digital input (Disable PL control)
Digital outputs
1 x digital output (Open collector)
1 x digital output (NO contact type)
1 x digital output (SPDT Single Pole Double Throw contact type)
1 x digital output (NO contact type)
1 x digital output (SPDT Single Pole Double Throw contact type)
Analog inputs
1 x analog input (0-10V DC)
1 x analog input (0-20mA / 4-20mA)
1 x analog input (0-20mA / 4-20mA)
Analog outputs
1 x analog output (0-10V DC / 2-10V DC)
Degree of protection
IP20
Net Height (mm)
195 mm
Net Width (mm)
90 mm
Net Depth (mm)
105 mm
Ambient air temperature for operation
-10...+50 °C
Ambient air temperature for storage
-40...+70 °C
Technology used in component
EMC filter category C2 / C4 / C4 (class H)
Current consumption
(Low overload IL) 6.8A
Application type
General-purpose microdrive
Manufacturer product status
Commercialized
Compliant with standard(s)
EN61800-3
61800-5-1
EN60204-1
CE
UL
cUL
IEC
RoHS compliant
61800-5-1
EN60204-1
CE
UL
cUL
IEC
RoHS compliant
Benefits
Ease of use (preset application macros; startup wizard; diagnostic capabilities)
Compact space-saving design
Rugged and reliable (150% torque for one minute; 50C rated; conformal coated boards)
DIN rail and screw mountable
Side-by-side installation
Industry leading efficiency delivers energy savings to the customer
Integrated 5% DC choke (FS4 and FS5)
Integrated EMC filters make the unit suitable for commercial and industrial networks
Temperature-controlled fan
PID controller as standard
Compact space-saving design
Rugged and reliable (150% torque for one minute; 50C rated; conformal coated boards)
DIN rail and screw mountable
Side-by-side installation
Industry leading efficiency delivers energy savings to the customer
Integrated 5% DC choke (FS4 and FS5)
Integrated EMC filters make the unit suitable for commercial and industrial networks
Temperature-controlled fan
PID controller as standard
Related Documents