Eaton
NFXF25A0-1
Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter - Eaton / Cutler-Hammer (NFX9000) - Rated input voltage (Single-phase (2P)) 90Vac-130Vac - Rated output current 1.6A (Continuous output Amp rating) - Rated power 0.18kW (90-130Vac) / 1/4HP (90-130Vac) - IP20 - with RS-485 communication capability
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
NFXF25A0-1
Please add this item to cart to request a quote.
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Eaton - NFX9000NFXF25A0-1
Description
Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter - Eaton / Cutler-Hammer (NFX9000) - Rated input voltage (Single-phase (2P)) 90Vac-130Vac - Rated output current 1.6A (Continuous output Amp rating) - Rated power 0.18kW (90-130Vac) / 1/4HP (90-130Vac) - IP20 - with RS-485 communication capability
Specifications
Primary brand
Eaton
Secondary brand
Cutler-Hammer
Main function
Variable Speed / Frequency Drive (VSD/VFD) / Inverter
Product series / family name
NFX9000
Network frequency
(input) 50-60 Hz
(output) 0.1-400 Hz
(output) 0.1-400 Hz
Functions
Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter
DC Injection Braking
External Fault
Jog mode
Fault Reset (STOP/RESET or terminal input)
Jump Frequencies
Parameter Security
2 Preset Speeds
Reversing Keypad or terminal
Speed Setting
RUN/STOP Control
Stop Modes
DC Injection Braking
External Fault
Jog mode
Fault Reset (STOP/RESET or terminal input)
Jump Frequencies
Parameter Security
2 Preset Speeds
Reversing Keypad or terminal
Speed Setting
RUN/STOP Control
Stop Modes
Supply voltage (AC)
90Vac-130Vac
Type of network
Single-phase input (2P)
Rated current
1.6A (Continuous output Amp rating; 90-130Vac)
Rated active power (kW)
0.18kW (90-130Vac)
Rated power (HP)
1/4HP (90-130Vac)
Protection functions
Ground Fault
Overload
Overcurrent
Overvoltage
Undervoltage
Overtemperature
Overload Limit
Overload
Overcurrent
Overvoltage
Undervoltage
Overtemperature
Overload Limit
Communication protocol
RS-485
Digital inputs
1 x digital input (FWD / STOP)
1 x digital input (REV / STOP)
1 x digital input (Reset)
1 x digital input (Multi-Step 1)
1 x digital input (REV / STOP)
1 x digital input (Reset)
1 x digital input (Multi-Step 1)
Digital outputs
1 x digital output (NO contact type)
Analog inputs
1 x analog input (4-20mA / 0-10V DC)
Degree of protection
IP20
Ambient air temperature for operation
-10...+40 °C
Display
Alphanumeric display
Manufacturer product status
Commercialized
Compliant with standard(s)
IEEE
NEC
UL
cUL
CE
NEC
UL
cUL
CE
Benefits
Provides 150% starting torque and advanced low speed control
Most informative operator’s interface in this class of VFD provided as standard
All parameters diagnostic information and metering values are displayed with a bright 4-character LED display
Provide enhanced application flexibility
Direct connection to serial communications networks
Operate three-phase motor with single-phase supply
Most informative operator’s interface in this class of VFD provided as standard
All parameters diagnostic information and metering values are displayed with a bright 4-character LED display
Provide enhanced application flexibility
Direct connection to serial communications networks
Operate three-phase motor with single-phase supply
Related Documents
Name | Last Update | Language |
---|---|---|
Eaton - NFX9000 MVX9000 SLX9000 HVX9000 IntelliPass - Catalogue.pdf | 23 Jun 2020 | English (US) |