IDEC
RR3B-ULCAC12V
Electromechanical power relay with visual indic. + check btn. - IDEC (RR Series) - control voltage 9.6-13.2Vac (12Vac nom.) - Rated current 10A (continuous) / 10A (resistive load; 110Vac) - 3C/O / 3PDT (3 Pole Double Throw) contact - 3-poles (3P) - Blade connection - Silver (Ag) contact - Plug-in mounting on DIN rail / Through pnl. sckt.
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
RR3B-ULCAC12V
Online Price
$16.39
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
RR3B-ULCAC12VIDEC - RR Series
Description
Electromechanical power relay with visual indic. + check btn. - IDEC (RR Series) - control voltage 9.6-13.2Vac (12Vac nom.) - Rated current 10A (continuous) / 10A (resistive load; 110Vac) - 3C/O / 3PDT (3 Pole Double Throw) contact - 3-poles (3P) - Blade connection - Silver (Ag) contact - Plug-in mounting on DIN rail / Through pnl. sckt.
Specifications
Primary brand
IDEC
Main function
Relay
Product series / family name
RR Series
Functions
Electromechanical power relay
Design
visual indic.
check btn.
check btn.
Poles
3-poles (3P)
Resistance (Ω)
30mΩ max. contact resistance (measured with 1A at 5Vdc using voltage drop method)
100MΩ min. (insulation resistance; at 500Vdc)
100MΩ min. (insulation resistance; at 500Vdc)
Rated current
10A (continuous)
10A (resistive load; 110Vac)
7.5A (resistive load; 220Vac)
10A (resistive load; 30Vdc)
7.5A (inductive load; 110Vac)
5A (inductive load; 220Vac)
5A (inductive load; 30Vdc)
10mA (minimum applicable load; 1Vdc)
10A (resistive load; 110Vac)
7.5A (resistive load; 220Vac)
10A (resistive load; 30Vdc)
7.5A (inductive load; 110Vac)
5A (inductive load; 220Vac)
5A (inductive load; 30Vdc)
10mA (minimum applicable load; 1Vdc)
Rated voltage (AC)
2000Vac (for 1 min.; dielectric strength; between live and dead parts)
2000Vac (1min) dielectric strength between contacts and coil
2000Vac (for 1 min.; dielectric strength; between contacts of different poles)
1000Vac (1min) dielectric strength between contacts of the same pole
2000Vac (1min) dielectric strength between contacts and coil
2000Vac (for 1 min.; dielectric strength; between contacts of different poles)
1000Vac (1min) dielectric strength between contacts of the same pole
Connection type
Blade connection
Control Voltage (AC)
9.6-13.2Vac (12Vac nom.)
Mounting mode
Plug-in mounting on DIN rail / Through pnl. sckt.
Response time
(OFF=>ON switching; max.) 25ms / 0.025 s
(ON=>OFF switching; max.) 25ms / 0.025 s
(ON=>OFF switching; max.) 25ms / 0.025 s
Contacts type
3C/O / 3PDT (3 Pole Double Throw) contact
Dimensions
H54.8mm x W36mm x D36mm
Ambient air temperature for operation
-25...+40 °C
Power consumption
1.5 W
Electrical durability (with load)
(220Vac; 5A; frequency 1800 cycles/hour) min. 200 000 operations
Mechanical durability (at no load)
(18 000 cycles/hour) min. 10 000 000 operations
Power consumption
(50Hz) 3 VA
(60Hz) 2.5 VA
(60Hz) 2.5 VA
Manufacturer product status
Commercialized
Equivalent to
RR3BULCAC12V
Compliant with standard(s)
UL
CSA
CSA
Contacts coating
Silver (Ag)
Related Documents
Name | Last Update | Language |
---|---|---|
IDEC - RR Series - Catalogue.pdf | 21 Oct 2021 | English (US) |
IDEC - RR Series 2 - Catalogue.pdf | 21 Oct 2021 | English (US) |