Eaton
SLX01034BA
Enclosed Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter - Eaton / Cutler-Hammer (SLX9000) - Rated input voltage (3-phase (3P)) 480Vac - Rated output current 16A (Low overload IL) - Rated power 7.5kW (Low overload IL) / 10HP (Low overload IL) - Frame size MF5 - UL type 3R / NEMA 3R - with EMI filter - with RS-232 communication capability - with Brake chopper
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
SLX01034BA
Please add this item to cart to request a quote.
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Eaton - SLX9000SLX01034BA
Description
Enclosed Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter - Eaton / Cutler-Hammer (SLX9000) - Rated input voltage (3-phase (3P)) 480Vac - Rated output current 16A (Low overload IL) - Rated power 7.5kW (Low overload IL) / 10HP (Low overload IL) - Frame size MF5 - UL type 3R / NEMA 3R - with EMI filter - with RS-232 communication capability - with Brake chopper
Specifications
Primary brand
Eaton
Secondary brand
Cutler-Hammer
Main function
Variable Speed / Frequency Drive (VSD/VFD) / Inverter
Product series / family name
SLX9000
Network frequency
(input) 45-66 Hz
(output) 0-320 Hz
(output) 0-320 Hz
Functions
Enclosed Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter
Brake chopper
Line reactors
Local/Remote keypad
Electronic Reversing
Dynamic Braking
DC Braking
PID Setpoint Controller
Critical Speed Lockout
Current (Torque) Limit
Adjustable Acceleration/Deceleration
Linear or S Curve Accel/Decel
Jog at Preset Speed
Thread/Preset Speeds
Automatic Restart
Coasting Motor Start
Coast or Ramp Stop Selection
Elapsed Time Meter
Carrier Frequency Adjustment
Brake chopper
Line reactors
Local/Remote keypad
Electronic Reversing
Dynamic Braking
DC Braking
PID Setpoint Controller
Critical Speed Lockout
Current (Torque) Limit
Adjustable Acceleration/Deceleration
Linear or S Curve Accel/Decel
Jog at Preset Speed
Thread/Preset Speeds
Automatic Restart
Coasting Motor Start
Coast or Ramp Stop Selection
Elapsed Time Meter
Carrier Frequency Adjustment
Supply voltage (AC)
480Vac
Type of network
3-phase input (3P)
Rated current
16A (Low overload IL)
Rated active power (kW)
7.5kW (Low overload IL)
Rated power (HP)
10HP (Low overload IL)
Protection functions
Phase Rotation Insensitive
Input Phase Loss
Input Overvoltage
Line Surge Protection
Output Short Circuit
Output Ground Fault
Output Phase Protection
Overtemperature
DC Overvoltage
Drive Overload
Motor Overload
Keypad Lockout
Fault Alarm Output
Built-In Diagnostics
Input Phase Loss
Input Overvoltage
Line Surge Protection
Output Short Circuit
Output Ground Fault
Output Phase Protection
Overtemperature
DC Overvoltage
Drive Overload
Motor Overload
Keypad Lockout
Fault Alarm Output
Built-In Diagnostics
Communication protocol
RS-232
Operating mode
Frequency control (V/f)
Sensorless vector control
IR and Slip Compensation
Sensorless vector control
IR and Slip Compensation
Digital inputs
3 x digital inputs (programmable)
Digital outputs
1 x digital output (SPDT Single Pole Double Throw contact type)
Analog inputs
2 x analog inputs (0-20mA / 4-20mA / 0-10V DC)
Analog outputs
1 x analog output (0-20mA)
Degree of protection
UL type 3R
NEMA 3R
NEMA 3R
Ambient air temperature for operation
0...+40 °C
Ambient air temperature for storage
-40...+60 °C
Technology used in component
EMI filter
Manufacturer product status
Commercialized
Compliant with standard(s)
UL
cUL
cUL
Related Documents
Name | Last Update | Language |
---|---|---|
Eaton - NFX9000 MVX9000 SLX9000 HVX9000 IntelliPass - Catalogue.pdf | 23 Jun 2020 | English (US) |