T8VQD3GS0EAC0EACT8V 2000 PR332/P LSIG In=2000A 3p F F UL/CSA 100% (T8VQD3GS0EAC0EAC)
T8V 2000 PR332/P LSIG In=2000A 3p F F UL/CSA 100% (T8VQD3GS0EAC0EAC)
Moulded / Molded Case Circuit Breaker (MCCB) with closing solen. (110-120Vac/dc) + spring charging mtr. (100-130Vac/dc) + undervoltage solen. (110-120Vac/dc) + mechanical counter + padlock provision - UL 100% rated version - ABB / SACE (Tmax T (UL/CSA) series) - T8V 2000 PR332/P LSIG In=2000A 3p F F UL/CSA 100% - 3-poles (3P3d) - Rated current 2000A - Short circuit rating 125kA (480Vac; UL489) - Electronic (PR332/P LSIG) trip unit - 4 aux. contacts - equivalent to T8VQD3GS0EAC0EAC
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
T8VQD3GS0EAC0EAC
Online Price
$20,343.33
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
T8VQD3GS0EAC0EACABB - Tmax T UL/CSA
Description
Moulded / Molded Case Circuit Breaker (MCCB) with closing solen. (110-120Vac/dc) + spring charging mtr. (100-130Vac/dc) + undervoltage solen. (110-120Vac/dc) + mechanical counter + padlock provision - UL 100% rated version - ABB / SACE (Tmax T (UL/CSA) series) - T8V 2000 PR332/P LSIG In=2000A 3p F F UL/CSA 100% - 3-poles (3P3d) - Rated current 2000A - Short circuit rating 125kA (480Vac; UL489) - Electronic (PR332/P LSIG) trip unit - 4 aux. contacts - equivalent to T8VQD3GS0EAC0EAC
Specifications
Primary brand
ABB
Secondary brand
SACE
Main function
Moulded Case Circuit Breaker (MCCB)
Product series / family name
Tmax T (UL/CSA)
Sub-range name
T8V complete breakers
Functions
Moulded / Molded Case Circuit Breaker (MCCB)
Design
closing solen. (110-120Vac/dc)
spring charging mtr. (100-130Vac/dc)
undervoltage solen. (110-120Vac/dc)
mechanical counter
padlock provision
UL 100% rated version
spring charging mtr. (100-130Vac/dc)
undervoltage solen. (110-120Vac/dc)
mechanical counter
padlock provision
UL 100% rated version
Poles
3-poles (3P3d)
Rated current
2000A
Trip current rating
2000 AT
Frame current rating
2000 AF
Rated voltage (AC)
600Vac
Connection type
Ring-lug or bar connections
Short circuit breaking rating
125kA (240Vac; UL489)
125kA (480Vac; UL489)
100kA (600Vac; UL489)
125kA (480Vac; UL489)
100kA (600Vac; UL489)
Trip unit type
Technology = Electronic
Series = PR332/P LSIG
Protection = LSIG
Display = LCD
Series = PR332/P LSIG
Protection = LSIG
Display = LCD
Protection functions
(L) Protection against overload
(S) Protection against short-circuit with time delay
(I) Instantaneous protection against short-circuit
(G) Protection against earth fault
(OT) Protection against overtemperature of the trip unit (instantaneous trip)
(U) Unbalanced phase / phase loss
(S) Protection against short-circuit with time delay
(I) Instantaneous protection against short-circuit
(G) Protection against earth fault
(OT) Protection against overtemperature of the trip unit (instantaneous trip)
(U) Unbalanced phase / phase loss
Protection settings
L - Protection against overload -- adjustable 0.14...1 x In (280A...2000A)
S - Protection against short-circuit with time delay -- adjustable 0.6...10 x In (1200A...20000A); with adjustable time trip curve
I - Instantaneous protection against short-circuit -- adjustable 1.5...15 x In (3000A...30000A)
G - Protection against earth fault -- adjustable 0.2...1 x In (0.1...0.8s time delay)
S - Protection against short-circuit with time delay -- adjustable 0.6...10 x In (1200A...20000A); with adjustable time trip curve
I - Instantaneous protection against short-circuit -- adjustable 1.5...15 x In (3000A...30000A)
G - Protection against earth fault -- adjustable 0.2...1 x In (0.1...0.8s time delay)
Measurement function
Phase currents
Neutral current
Ground current
Voltage (phase-phase/phase-neutral/residual)
Power (active/reactive/apparent)
Power factor
Frequency and peak factor
Energy (active/reactive/apparent)
Harmonic analysis
Total number of operations
Total number of trips
Number of trip tests
Number of manual operations
Number of separate trips for each protection function
Contact wear (%)
Neutral current
Ground current
Voltage (phase-phase/phase-neutral/residual)
Power (active/reactive/apparent)
Power factor
Frequency and peak factor
Energy (active/reactive/apparent)
Harmonic analysis
Total number of operations
Total number of trips
Number of trip tests
Number of manual operations
Number of separate trips for each protection function
Contact wear (%)
Operating mode
Stored energy closing/opening mechanism
Contacts type
4 aux. contacts
Mechanical durability (at no load)
15000 operations
Order code / Manufacturer SKU
T8V 2000 PR332/P LSIG In=2000A 3p F F UL/CSA 100%
Manufacturer product status
Commercialized
Equivalent to
T8VQD3GS0EAC0EAC
Compliant with standard(s)
UL 489
CSA C22.2
CSA C22.2