Schneider Electric
XPSMC16ZCSafety controller XPS-MC - 24Vdc - 16 input - 32 LEDs signalling
Safety controller XPS-MC - 24Vdc - 16 input - 32 LEDs signalling
Safety Programmable Logic Controller (PLC) CPU processor module with integrated I/Os - SIL3 - Schneider Electric / Modicon (Modicon Preventa XPSMC series) - 26I/Os [16DI (16 x safety inputs) + 10DO (4 x digital outputs (rly. contact outputs) + 6 x digital outputs (solid-state safety outputs))] - with Modbus + CANopen communication capability - DIN rail (35mm) mounting - with removable screw / spring term. blck. - IP20 - Red color - Rated for +14...+131°F / -10...+55°C ambient - replaces XPSMC16ZCPACK
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
XPSMC16ZC
Online Price
$2,160.00
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
XPSMC16ZCSchneider Electric - Modicon Preventa XPSMC CPUs
Description
Safety Programmable Logic Controller (PLC) CPU processor module with integrated I/Os - SIL3 - Schneider Electric / Modicon (Modicon Preventa XPSMC series) - 26I/Os [16DI (16 x safety inputs) + 10DO (4 x digital outputs (rly. contact outputs) + 6 x digital outputs (solid-state safety outputs))] - with Modbus + CANopen communication capability - DIN rail (35mm) mounting - with removable screw / spring term. blck. - IP20 - Red color - Rated for +14...+131°F / -10...+55°C ambient - replaces XPSMC16ZCPACK
Specifications
Primary brand
Schneider Electric
Secondary brand
Modicon
Main function
Safety CPU unit
Product series / family name
Modicon Preventa XPSMC
Functions
Safety Programmable Logic Controller (PLC) CPU processor module
Dynamic monitoring of hydraulic valves on linear presses
Eccentric press
Emergency stop monitoring / with or without time delay / 1 or 2-channel wiring
Enabling switch monitoring -- 2 or 3 contacts
Foot switch monitoring
Guard monitoring for injection presses and blowing machines
Guard monitoring with 1 or 2 limit switches
Hydraulic press
Magnetic switch monitoring
Monitoring safety stop at top dead center on eccentric press
Muting function of light curtains
Position selector
Safety mat monitoring
Safety time delays
Shaft/chain breaking monitor
Zero speed detection
Light curtain monitoring category 4 EN/IEC 61496
Two-hand control category 3 EN 574/ISO 13851
Dynamic monitoring of hydraulic valves on linear presses
Eccentric press
Emergency stop monitoring / with or without time delay / 1 or 2-channel wiring
Enabling switch monitoring -- 2 or 3 contacts
Foot switch monitoring
Guard monitoring for injection presses and blowing machines
Guard monitoring with 1 or 2 limit switches
Hydraulic press
Magnetic switch monitoring
Monitoring safety stop at top dead center on eccentric press
Muting function of light curtains
Position selector
Safety mat monitoring
Safety time delays
Shaft/chain breaking monitor
Zero speed detection
Light curtain monitoring category 4 EN/IEC 61496
Two-hand control category 3 EN 574/ISO 13851
Design
integrated I/Os
for Emergency stop / limit switches / light curtain / safety mats
for Emergency stop / limit switches / light curtain / safety mats
Supply voltage (DC)
19-30Vdc (24Vdc nom.; externally supplied)
Display
32 LEDs
Color
Red color
Programming languages
programming software XPSMFWIN (available on Safety Suite V2 software pack)
Connection type
removable screw / spring term. blck.
1 x 9-pin D-SUB (male) connector (for connection on CANopen bus)
1 x RJ45 connector (for connecting Modbus bus)
1 x 9-pin D-SUB (male) connector (for connection on CANopen bus)
1 x RJ45 connector (for connecting Modbus bus)
Protection functions
external fuse 16A (input protection type)
Communication protocol
Modbus
CANopen
CANopen
Mounting mode
DIN rail (35mm) mounting
Digital inputs
16 x safety inputs
Digital outputs
4 x digital outputs (rly. contact outputs)
6 x digital outputs (solid-state safety outputs)
6 x digital outputs (solid-state safety outputs)
Degree of protection
IP20
Ambient air temperature for operation
+14...+131°F / -10...+55 °C
Ambient air temperature for storage
-13...+185°F / -25...+85 °C
Order code / Manufacturer SKU
XPSMC16ZC
Manufacturer product status
Commercialized
Replaces
XPSMC16ZCPACK
Compliant with standard(s)
CSA
EN 574/ISO 13851
EN 1760-1/ISO 13856-1
EN/IEC 61496-1
EN/IEC 60204-1
IEC 61508
EN/IEC 60947-5-1
EN 954-1/EN/ISO 13849-1
UL
Certified by TUV Rheinland as suitable for use in an SIL3 level safety function
EN 574/ISO 13851
EN 1760-1/ISO 13856-1
EN/IEC 61496-1
EN/IEC 60204-1
IEC 61508
EN/IEC 60947-5-1
EN 954-1/EN/ISO 13849-1
UL
Certified by TUV Rheinland as suitable for use in an SIL3 level safety function
Class
SIL3
Benefits
Configurable safety controllers XPSMCxxZx are designed to provide a solution for safety applications requiring conformity to Performance Level PL e/Category 4 EN/ISO 13849-1 and SIL3 EN/IEC 61508
Location of origin
France (FR)
Related Documents
Name | Last Update | Language |
---|---|---|
Schneider Electric - Programmable Logic Controllers (PLCs) - Preventa XPSMC - Catalog.pdf | 08 Jan 2023 | English (US) |