ABB
1SFL587002R3422AF305-30-22-34
AF305-30-22-34
Magnetic contactor with direct P.L.C. control interface - only for 50Hz networks - ABB (AF series) - AF305-30-22-34 - 3-poles (3P) - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Rated current 305A (AC-3) - Rated power 160kW / 250HP - Control coil voltage 250Vac-500Vac (277Vac / 380Vac / 400Vac / 415Vac / 440Vac / 480Vac) (50Hz/60Hz) / 250Vdc-500Vdc - with 2NO+2NC aux. contacts - Lugs / bars connections - Mounting on plate
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
1SFL587002R3422
Online Price
$1,194.77
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
ABB - AF series contactors1SFL587002R3422
Description
Magnetic contactor with direct P.L.C. control interface - only for 50Hz networks - ABB (AF series) - AF305-30-22-34 - 3-poles (3P) - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Rated current 305A (AC-3) - Rated power 160kW / 250HP - Control coil voltage 250Vac-500Vac (277Vac / 380Vac / 400Vac / 415Vac / 440Vac / 480Vac) (50Hz/60Hz) / 250Vdc-500Vdc - with 2NO+2NC aux. contacts - Lugs / bars connections - Mounting on plate
Specifications
Primary brand
ABB
Main function
Contactor
Product series / family name
AF series
Sub-range name
AF305 contactors
Functions
Magnetic contactor
Design
direct P.L.C. control interface
only for 50Hz networks
only for 50Hz networks
Poles
3-poles (3P)
Rated current
500A (690Vac; 40°C; AC-1)
400A (690Vac; 55°C; AC-1)
325A (690Vac; 70°C; AC-1)
305A (220-440Vac; AC-3)
290A (500Vac; AC-3)
290A (690Vac; AC-3)
131A (1000Vac; AC-3)
400A (600Vac; UL/CSA general use rating)
400A (690Vac; 55°C; AC-1)
325A (690Vac; 70°C; AC-1)
305A (220-440Vac; AC-3)
290A (500Vac; AC-3)
290A (690Vac; AC-3)
131A (1000Vac; AC-3)
400A (600Vac; UL/CSA general use rating)
Rated active power (kW)
90kW (220-240Vac; AC-3)
160kW (380-440Vac; AC-3)
200kW (500Vac; AC-3)
250kW (690Vac; AC-3)
185kW (1000Vac; AC-3)
160kW (380-440Vac; AC-3)
200kW (500Vac; AC-3)
250kW (690Vac; AC-3)
185kW (1000Vac; AC-3)
Rated power (HP)
100HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA)
125HP (220-240Vac; 3-phase; 50Hz/60Hz; UL/CSA)
250HP (440-480Vac; 3-phase; 50Hz/60Hz; UL/CSA)
300HP (550Vac-600Vac; 3-phase; 50Hz/60Hz; UL/CSA)
125HP (220-240Vac; 3-phase; 50Hz/60Hz; UL/CSA)
250HP (440-480Vac; 3-phase; 50Hz/60Hz; UL/CSA)
300HP (550Vac-600Vac; 3-phase; 50Hz/60Hz; UL/CSA)
Rated operating voltage (Ue)
1000 V
(UL/CSA) 600 V
(UL/CSA) 600 V
Rated impulse voltage (Uimp)
8 kV
Rated insulation voltage (Ui)
(IEC/VDE) 1000 V
(UL/CSA) 600 V
(UL/CSA) 600 V
Connection type
Lugs / bars connections
Control Voltage (AC)
250Vac-500Vac (277Vac / 380Vac / 400Vac / 415Vac / 440Vac / 480Vac) (50Hz/60Hz)
Control Voltage (DC)
250Vdc-500Vdc
Mounting mode
Mounting on plate
Normally Open (NO) auxliary contacts
2 NO contacts
Normally Closed (NC) auxiliary contacts
2 NC contacts
Net Height (mm)
225 mm
Net Width (mm)
140 mm
Net Depth (mm)
195.5 mm
Current consumption
420VA inrush (coil; AC)
21VA holding (coil; AC)
600W inrush (coil; DC)
4.7W holding (coil; DC)
21VA holding (coil; AC)
600W inrush (coil; DC)
4.7W holding (coil; DC)
Application type
Direct On Line (DOL)
FVNR (Full-Voltage Non-Rv.)
FVNR (Full-Voltage Non-Rv.)
Order code / Manufacturer SKU
AF305-30-22-34
Manufacturer product status
Commercialized
Equivalent to
AF305302234
UPC code
88861443222
UNSPSC code
39121529
Compliant with standard(s)
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60529
UL
CSA
BV
DNV
GL
IEC/EN 60947-4-1
IEC/EN 60529
UL
CSA
BV
DNV
GL
Benefits
AF contactors for motor starting and power switching up to 2650A
The latest technology of electronically controlled coil is our standard
It offers multiple benefits over conventional alternatives and together with ABB's wide product offering it is an optimal configuration every time.
Optimized logistics -- Cut your costs
With its contactor and motor protection range ABB has managed to reduce the number of contactor coils to just four.
Total number of product variants has been reduced by up to 90%.
This simplifies the customers' logistics while cutting storage and administration costs.
Continuous operation -- Secure uptime
Prevent stoppages caused by voltage fluctuations.
The AF contactor ensures distinct operation in unstable networks and signifies a major advance in motor control and power switching.
Voltage sags / dips / surges pose no threat.
The AF contactor secures your uptime.
Speed up your projects -- Simplify design
Use the same part number in Europe Asia and North America as one contactor coil now handles 100 V - 250 V AC (50 / 60Hz) / DC.
By reducing contactor coil energy consumption by up to 80% panels can be built smaller and transformers more compact.
Reliable in all networks -- The electronic system within the AF contactor continuously monitor the current and voltage apply to the coil.
The contactor is safely operated in an always optimized condition and hum free.
Four coils for the entire voltage range
AF contactors feature both AC and DC control in the same product.
The total number of product variants compared to a conventional range is reduced by 90%.
Only four coils are required to cover 24 V AC / 20 V DC - 500 V AC / DC.
Wide control voltage range
With conventional contactor technology different contactors are needed for different network voltages.
Thanks to the wide operating range of the AF contactor it can operate just as well in Europe as in Asia or North America.
The core coil of the AF contactor range covers 100-250 V AC / DC (50 / 60 Hz)
Built-in surge suppression
With conventional contactor technology it is recommended to use an external surge suppressor that could cost as much as half of the contactor.
With the AF technology the surges are handled by the contactor and never reach the control circuit.
One less product and one less complication to worry about
Easy fast and secure starters assembly
The AF contactor range is perfect for motor starting applications and for solutions where space is limited.
You can create any motor starting type and save assembly time with a complete range of accessories and connection sets.
Compact size
The AF contactor is compact in size and has had its width reduced by up to 30% thanks to an 80% coil consumption reduction.
Save space
Interlocking reversing pairs require no spacing between contactors meaning you can fit more functionality into cabinets or other enclosures.
Easy to use accessories
1-pole / 2-pole / 4-pole auxiliary contact blocks front or side mounted are available for a great flexibility up to 96A contactors.
116 to 2650 A contactors can take up to 2 side mounted auxiliary contact blocks without adding to its width.
Coil connection terminals mechanical and electrical interlocks and electronic timers are easily connected through the snap-to-connect function.
Great flexibility for coil terminal access
Contactors up to 96 A offer free choice of coil terminal access from top / bottom / top + bottom / front only.
Simple connection and maintenance
The main terminals of AF116 to AF2650 contactors are at the contactors' back to facilitate your bus bars connections.
It also allows easy contact inspection and maintenance from AF400 and above.
The latest technology of electronically controlled coil is our standard
It offers multiple benefits over conventional alternatives and together with ABB's wide product offering it is an optimal configuration every time.
Optimized logistics -- Cut your costs
With its contactor and motor protection range ABB has managed to reduce the number of contactor coils to just four.
Total number of product variants has been reduced by up to 90%.
This simplifies the customers' logistics while cutting storage and administration costs.
Continuous operation -- Secure uptime
Prevent stoppages caused by voltage fluctuations.
The AF contactor ensures distinct operation in unstable networks and signifies a major advance in motor control and power switching.
Voltage sags / dips / surges pose no threat.
The AF contactor secures your uptime.
Speed up your projects -- Simplify design
Use the same part number in Europe Asia and North America as one contactor coil now handles 100 V - 250 V AC (50 / 60Hz) / DC.
By reducing contactor coil energy consumption by up to 80% panels can be built smaller and transformers more compact.
Reliable in all networks -- The electronic system within the AF contactor continuously monitor the current and voltage apply to the coil.
The contactor is safely operated in an always optimized condition and hum free.
Four coils for the entire voltage range
AF contactors feature both AC and DC control in the same product.
The total number of product variants compared to a conventional range is reduced by 90%.
Only four coils are required to cover 24 V AC / 20 V DC - 500 V AC / DC.
Wide control voltage range
With conventional contactor technology different contactors are needed for different network voltages.
Thanks to the wide operating range of the AF contactor it can operate just as well in Europe as in Asia or North America.
The core coil of the AF contactor range covers 100-250 V AC / DC (50 / 60 Hz)
Built-in surge suppression
With conventional contactor technology it is recommended to use an external surge suppressor that could cost as much as half of the contactor.
With the AF technology the surges are handled by the contactor and never reach the control circuit.
One less product and one less complication to worry about
Easy fast and secure starters assembly
The AF contactor range is perfect for motor starting applications and for solutions where space is limited.
You can create any motor starting type and save assembly time with a complete range of accessories and connection sets.
Compact size
The AF contactor is compact in size and has had its width reduced by up to 30% thanks to an 80% coil consumption reduction.
Save space
Interlocking reversing pairs require no spacing between contactors meaning you can fit more functionality into cabinets or other enclosures.
Easy to use accessories
1-pole / 2-pole / 4-pole auxiliary contact blocks front or side mounted are available for a great flexibility up to 96A contactors.
116 to 2650 A contactors can take up to 2 side mounted auxiliary contact blocks without adding to its width.
Coil connection terminals mechanical and electrical interlocks and electronic timers are easily connected through the snap-to-connect function.
Great flexibility for coil terminal access
Contactors up to 96 A offer free choice of coil terminal access from top / bottom / top + bottom / front only.
Simple connection and maintenance
The main terminals of AF116 to AF2650 contactors are at the contactors' back to facilitate your bus bars connections.
It also allows easy contact inspection and maintenance from AF400 and above.
Operating rate
(at no load) 300 Cycles/hour
(AC-1) 300 Cycles/hour
(AC-3) 300 Cycles/hour
(AC-2 / AC-4) 150 Cycles/hour
(AC-1) 300 Cycles/hour
(AC-3) 300 Cycles/hour
(AC-2 / AC-4) 150 Cycles/hour
Related Documents
Name | Last Update | Language |
---|---|---|
ABB - Across the line contactors - Catalog.pdf | 12 Dec 2021 | English (US) |
ABB - Contactors - Catalog.pdf | 13 Oct 2022 | English (US) |