Schneider Electric
BDF16015Circuit breaker PowerPacT B-Frame 1P-1t 15A 600Y/347Vac 14kA terminal nut 80% rated
Circuit breaker PowerPacT B-Frame 1P-1t 15A 600Y/347Vac 14kA terminal nut 80% rated
Moulded Case Circuit Breaker (MCCB) - PowerPact B-Frame 100 TMD 1P-1t 15A 600Y/347Vac 14kA term. nut - 80% rated - Square D by Schneider Electric - 1-pole (1P) - Rated current 15A - Rated voltage 600Vac - Short circuit breaking capacity 14kA (600Y/347Vac; UL489) - Thermal-Magnetic (fixed) (TMD) trip unit - Term. nut kit (for fixed busbar connection) on both line and load sides
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
BDF16015
Online Price
$343.00
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
BDF16015Schneider Electric - PowerPact B-Frame - PowerPact BDF
Description
Moulded Case Circuit Breaker (MCCB) - PowerPact B-Frame 100 TMD 1P-1t 15A 600Y/347Vac 14kA term. nut - 80% rated - Square D by Schneider Electric - 1-pole (1P) - Rated current 15A - Rated voltage 600Vac - Short circuit breaking capacity 14kA (600Y/347Vac; UL489) - Thermal-Magnetic (fixed) (TMD) trip unit - Term. nut kit (for fixed busbar connection) on both line and load sides
Specifications
Primary brand
Square D by Schneider Electric
Main function
Moulded Case Circuit Breaker (MCCB)
Product series / family name
PowerPacT B-Frame complete breakers
Sub-range name
PowerPacT BDF
Functions
Moulded Case Circuit Breaker (MCCB)
Design
PowerPact B-Frame 100 TMD 1P-1t 15A 600Y/347Vac 14kA term. nut
80% rated
80% rated
Poles
1-pole (1P)
Rated current
15A
Trip current rating
15 AT
Frame current rating
100 AF
Rated operating voltage (Ue)
240 V
Rated Voltage (DC)
125Vdc
Rated voltage (AC)
600Vac
600Y/347Vac
600Y/347Vac
Rated impulse voltage (Uimp)
8 kV
Rated insulation voltage (Ui)
800 V
Connection type
Term. nut kit (for fixed busbar connection) on both line and load sides
Short circuit breaking rating
25kA (240Vac; UL489)
18kA (480Vac; UL489)
18kA (480Y/277Vac; UL489)
14kA (600Y/347Vac; UL489)
10kA (250Vdc; UL489)
18kA (480Vac; UL489)
18kA (480Y/277Vac; UL489)
14kA (600Y/347Vac; UL489)
10kA (250Vdc; UL489)
Ultimate short circuit current breaking capacity (Icu)
25kA (220Vac/240Vac; IEC60947-2)
Service short circuit current breaking capacity (Ics)
25kA (220/240Vac; IEC60947-2)
Service short circuit current breaking capacity as a percentage of Icu (Ics%)
100 %
Trip unit type
Technology = Thermal-Magnetic (fixed)
Series = TMD
Display = none
Series = TMD
Display = none
Protection functions
Thermal protection (Overload)
Magnetic protection (Short-circuit)
Magnetic protection (Short-circuit)
Protection settings
Over-current -- fixed at 15A
S - Protection against short-circuit hold current -- fixed at 400A
S - Protection against short-circuit trip current -- fixed at 600A
S - Protection against short-circuit hold current -- fixed at 400A
S - Protection against short-circuit trip current -- fixed at 600A
Mounting mode
Fixed on DIN rail or individual unit mount on plate
Operating mode
Toggle (manual)
Degree of protection
IP40
Net Height (mm)
137 mm
Net Width (mm)
27 mm
Net Depth (mm)
80 mm
Electrical durability (with load)
(240Vac; at rated current In) 10000 operations
Mechanical durability (at no load)
15 000 operations
Utilisation category
A
Manufacturer product status
Commercialized
Compliant with standard(s)
EN / IEC (EU/Worldwide)
- CE marking
- EN/IEC 60947-2
- EN/IEC 60947-5-1
United States of America
- UL Listed
- UL 489
- NEMA
Canada
- CSA C22.2 No 5
Mexico
- NOM
- NMX J-266
China
- CCC
- CCS
- GB 14048.2
Marine approvals
- ABS (American Bureau of Shipping)
- BV (Bureau Veritas)
- DNV/GL (Det Norske Veritas/Germanischer Lloyd)
- LROS (Lloyds Register of Shipping)
- RINA (Registro Italia Navale)
- RMROS (Russian Maritime Register of Shipping)
Russia
- EAC
Korea
- KROS (Korean register of Shipping)
Japan
- NK (Nippon Kaiji Kyokai)
- CE marking
- EN/IEC 60947-2
- EN/IEC 60947-5-1
United States of America
- UL Listed
- UL 489
- NEMA
Canada
- CSA C22.2 No 5
Mexico
- NOM
- NMX J-266
China
- CCC
- CCS
- GB 14048.2
Marine approvals
- ABS (American Bureau of Shipping)
- BV (Bureau Veritas)
- DNV/GL (Det Norske Veritas/Germanischer Lloyd)
- LROS (Lloyds Register of Shipping)
- RINA (Registro Italia Navale)
- RMROS (Russian Maritime Register of Shipping)
Russia
- EAC
Korea
- KROS (Korean register of Shipping)
Japan
- NK (Nippon Kaiji Kyokai)
Benefits
PowerPacT B-frame circuit breakers provides economical thermal-magnetic circuit protection in a compact size
Fixed 15-125A thermal-magnetic protection up to 600Y/347Vac and 250Vdc
1 to 4-pole unit mount construction 1 to 3-pole I-Line construction
UL listed interrupting ratings from 18kA to 65kA at 480Vac
EverLink lugs a cable connection method that helps maintain low resistance connections
UL/CSA/NOM/IEC/CCC certified and CE marked for global acceptance
Fixed 15-125A thermal-magnetic protection up to 600Y/347Vac and 250Vdc
1 to 4-pole unit mount construction 1 to 3-pole I-Line construction
UL listed interrupting ratings from 18kA to 65kA at 480Vac
EverLink lugs a cable connection method that helps maintain low resistance connections
UL/CSA/NOM/IEC/CCC certified and CE marked for global acceptance
Mounting mode
Fixed on DIN rail
Surface mounting
Surface mounting
Degree of pollution
3
Related Documents
Name | Last Update | Language |
---|---|---|
Download official PDF datasheet for BDF16015 from Schneider Electric | 18 Jun 2021 | English (US) |
Schneider Electric 0100CT1501_SEC-03 - Digest Section 3 - Molded Case Circuit Breakers.pdf | 11 Mar 2019 | English (US) |
Schneider Electric 0100CT1501_SEC-07 - Digest Section 7 - Miniature and Molded Case Circuit Breakers.pdf | 11 Mar 2019 | English (US) |
Schneider Electric - PowerPacT MCCB-B-H-J-Q-frame - Catalogue.pdf | 31 Oct 2023 | English (US) |