PULS
FPS300.245-049-102
Field AC/DC Power supply unit (PSU) / converter with 3 individually protected switchable outputs + IO-Link interface - PULS (FIEPOS eFused FPS300 eFused 1AC series) - 24Vdc-28Vdc (adjustable) / 10A / 300W output - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-360Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)) - IP65 / IP67 - Hanging and fixing via integrated keyholes or by screw mounting - with 3-pin 7/8" male connector (INPUT; X1) + 5-pin M12 connector (IO-Link interface; X2) + 3 x 4-pin 7/8" connectors (OUTPUT; X3/X4/X5) - equivalent to #FPS300245049102
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
FPS300.245-049-102
Online Price
$880.00
Discount
10.0%
Net Price
$792.00
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
FPS300.245-049-102
Description
Field AC/DC Power supply unit (PSU) / converter with 3 individually protected switchable outputs + IO-Link interface - PULS (FIEPOS eFused FPS300 eFused 1AC series) - 24Vdc-28Vdc (adjustable) / 10A / 300W output - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-360Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)) - IP65 / IP67 - Hanging and fixing via integrated keyholes or by screw mounting - with 3-pin 7/8" male connector (INPUT; X1) + 5-pin M12 connector (IO-Link interface; X2) + 3 x 4-pin 7/8" connectors (OUTPUT; X3/X4/X5) - equivalent to #FPS300245049102
Specifications
Primary brand
PULS
Main function
Power supply unit
Product series / family name
FIEPOS eFused series
Sub-range name
FPS300 eFused 1AC series
Functions
Field AC/DC Power supply unit (PSU) / converter
Design
3 individually protected switchable outputs
IO-Link interface
IO-Link interface
Supply voltage (AC)
85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)
264-300Vac input overvoltage (for 500ms max.)
80Vac turn-ON voltage
70Vac shutdown voltage
264-300Vac input overvoltage (for 500ms max.)
80Vac turn-ON voltage
70Vac shutdown voltage
Supply voltage (DC)
88Vdc-360Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)
Display
LED bar-graph (20-200% load)
"Status" LED
3-color LEDs x 3 (OUT1-3 status)
"Status" LED
3-color LEDs x 3 (OUT1-3 status)
Type of network
Single-phase (1AC) or DC
Rated current
10A per output (at 24Vdc)
total max. output 15A (all channels; <45°C ambient)
total max. output 15A (all channels; <45°C ambient)
Rated power
360W (-25...+45°C)
300W (-25...+55°C)
150W at +70°C (derates linearly between +55°C and +70°C)
600W short-term (for 5s; at -25...+55°C)
300W short-term (for 5s; at +55...+70°C)
300W (-25...+55°C)
150W at +70°C (derates linearly between +55°C and +70°C)
600W short-term (for 5s; at -25...+55°C)
300W short-term (for 5s; at +55...+70°C)
Output voltage (DC)
24Vdc-28Vdc (adjustable)
200mV turn-ON overshoot
200mV turn-ON overshoot
Hold time
44ms (buffer time at 120/230Vac input)
Connection type
3-pin 7/8" male connector (INPUT; X1)
5-pin M12 connector (IO-Link interface; X2)
3 x 4-pin 7/8" connectors (OUTPUT; X3/X4/X5)
5-pin M12 connector (IO-Link interface; X2)
3 x 4-pin 7/8" connectors (OUTPUT; X3/X4/X5)
Protection functions
output overvoltage protection (31.8Vdc typ. / 32.5Vdc max.)
Overload / short-circuit current -- individual inverse time curve for each output (eFused electronic protection; see datasheet for details)
Over-temperature protection -- Output shutdown with automatic restart. Temperature sensors are installed on critical components inside the unit and turn the unit OFF in safety critical situations which can happen e.g. when ambient temperature is too high ventilation is obstructed or the derating requirements are not followed. There is no correlation between the operating temperature and turn-OFF temperature since this is dependent on input voltage load and installation methods.
Series / parallel operation -- not possible
Back-feeding loads max. 35V / 4J -- The unit is resistant and does not show a malfunction when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. For all 3 outputs in total
Overload / short-circuit current -- individual inverse time curve for each output (eFused electronic protection; see datasheet for details)
Over-temperature protection -- Output shutdown with automatic restart. Temperature sensors are installed on critical components inside the unit and turn the unit OFF in safety critical situations which can happen e.g. when ambient temperature is too high ventilation is obstructed or the derating requirements are not followed. There is no correlation between the operating temperature and turn-OFF temperature since this is dependent on input voltage load and installation methods.
Series / parallel operation -- not possible
Back-feeding loads max. 35V / 4J -- The unit is resistant and does not show a malfunction when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. For all 3 outputs in total
Efficiency
0.957 (230Vac input)
0.943 (120Vac input)
0.943 (120Vac input)
Communication protocol
IO-Link
Mounting mode
Hanging and fixing via integrated keyholes or by screw mounting
Time delay
2s start-up delay (100-230Vac input)
22ms rise time (nominal input; constant full current load; 0mF load capacitance)
48ms max. rise time (nominal input; constant full current load; 12.5mF load capacitance)
22ms rise time (nominal input; constant full current load; 0mF load capacitance)
48ms max. rise time (nominal input; constant full current load; 12.5mF load capacitance)
Degree of protection
IP65
IP67
IP67
Dimensions
W181mm x H183mm x D59mm
Material
Aluminium housing
Ambient air temperature for operation
-25...+55 °C
(with linear derating) +55...+70 °C
(with linear derating) +55...+70 °C
Current consumption
1.68A (230Vac input; full output)
3.2A (120Vac input; full output)
3.98A (100Vac input; full output)
2.9A (110Vdc input; 24Vdc / full output)
1.04A (300Vdc input; 24Vdc / full output)
6A peak inrush (at 230Vac input)
2.6A peak inrush (at 120Vac input)
3.2A (120Vac input; full output)
3.98A (100Vac input; full output)
2.9A (110Vdc input; 24Vdc / full output)
1.04A (300Vdc input; 24Vdc / full output)
6A peak inrush (at 230Vac input)
2.6A peak inrush (at 120Vac input)
Power dissipation/losses
(230Vac input; full output load) 13.5 W
(120Vac input; full output load) 18.1 W
(120Vac input; full output load) 18.1 W
Power factor (cos phi)
(230Vac input) 0.97
(120Vac input) 0.99
(120Vac input) 0.99
Manufacturer product status
Commercialized
Equivalent to
FPS300245049102
Capacitance
(output stage) 12500 μF
Compliant with standard(s)
CE marking
cULus Listed
IECEE CB Scheme IEC 62368-1 / IEC 61010-2-201
IEC 61010
IEC 60950-1
SEMI F47
VDMA 24364
ROHS
REACH
WEEE
IEC/EN 61558-2-16
cULus Listed
IECEE CB Scheme IEC 62368-1 / IEC 61010-2-201
IEC 61010
IEC 60950-1
SEMI F47
VDMA 24364
ROHS
REACH
WEEE
IEC/EN 61558-2-16
Benefits
IP65/67 Degree of protection
600W peak 5s
1AC 100-240V wide-range input
3 switchable outputs
Outputs for actors and sensors shares one channel
95.7% full load and excellent partial load efficiencies
DIN rail mounting possible (option "D")
Output connected to PE (PELV)
Version without connection to PE on request
Large output capacitors
Not potted
Negligible low input inrush current surge
Full power between -25°C and +55°C
Output-OK
3 years warranty
600W peak 5s
1AC 100-240V wide-range input
3 switchable outputs
Outputs for actors and sensors shares one channel
95.7% full load and excellent partial load efficiencies
DIN rail mounting possible (option "D")
Output connected to PE (PELV)
Version without connection to PE on request
Large output capacitors
Not potted
Negligible low input inrush current surge
Full power between -25°C and +55°C
Output-OK
3 years warranty
Ripple
50mVpp (20Hz...20MHz; 50Ω)