Schneider Electric
HGL26025CCircuit breaker PowerPacT H-Frame 2P 25A 600Vac/500Vdc 18kA lugs 100% rated
Circuit breaker PowerPacT H-Frame 2P 25A 600Vac/500Vdc 18kA lugs 100% rated
Moulded Case Circuit Breaker (MCCB) - PowerPact H-Frame 150 TMD 2P 25A 600Vac/500Vdc 18kA lugs - 100% rated - Square D by Schneider Electric - 2-poles (2P) - Rated current 25A - Rated voltage 600Vac - Short circuit breaking capacity 18kA (600Y/347Vac; UL489) - Thermal-Magnetic (fixed) (TMD) trip unit - Lugs on both load and line sides
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
HGL26025C
Online Price
$1,523.00
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Schneider Electric - PowerPact H-Frame - PowerPact HGLHGL26025C
Description
Moulded Case Circuit Breaker (MCCB) - PowerPact H-Frame 150 TMD 2P 25A 600Vac/500Vdc 18kA lugs - 100% rated - Square D by Schneider Electric - 2-poles (2P) - Rated current 25A - Rated voltage 600Vac - Short circuit breaking capacity 18kA (600Y/347Vac; UL489) - Thermal-Magnetic (fixed) (TMD) trip unit - Lugs on both load and line sides
Specifications
Primary brand
Square D by Schneider Electric
Main function
Moulded Case Circuit Breaker (MCCB)
Product series / family name
PowerPacT H-Frame complete breakers
Sub-range name
PowerPacT HGL
Functions
Moulded Case Circuit Breaker (MCCB)
Design
PowerPact H-Frame 150 TMD 2P 25A 600Vac/500Vdc 18kA lugs
100% rated
100% rated
Poles
2-poles (2P)
Rated current
25A
Trip current rating
25 AT
Frame current rating
150 AF
Rated operating voltage (Ue)
690 V
Rated Voltage (DC)
500Vdc
Rated voltage (AC)
600Vac
600Y/347Vac
600Y/347Vac
Rated impulse voltage (Uimp)
8 kV
Rated insulation voltage (Ui)
750 V
Connection type
Lugs on both load and line sides
Short circuit breaking rating
65kA (240Vac; UL489)
35kA (480Vac; UL489)
35kA (480Y/277Vac; UL489)
18kA (600Vac; UL489)
18kA (600Y/347Vac; UL489)
20kA (250Vdc; UL489)
20kA (500Vdc; UL489)
35kA (480Vac; UL489)
35kA (480Y/277Vac; UL489)
18kA (600Vac; UL489)
18kA (600Y/347Vac; UL489)
20kA (250Vdc; UL489)
20kA (500Vdc; UL489)
Ultimate short circuit current breaking capacity (Icu)
65kA (220Vac/240Vac; IEC60947-2)
35kA (380Vac/400Vac/415Vac; IEC60947-2)
35kA (440Vac/480Vac; IEC60947-2)
18kA (500Vac/525Vac; IEC60947-2)
35kA (380Vac/400Vac/415Vac; IEC60947-2)
35kA (440Vac/480Vac; IEC60947-2)
18kA (500Vac/525Vac; IEC60947-2)
Service short circuit current breaking capacity (Ics)
65kA (220/240Vac; IEC60947-2)
35kA (380/415Vac; IEC60947-2)
35kA (440/480Vac; IEC60947-2)
18kA (500/525Vac; IEC60947-2)
35kA (380/415Vac; IEC60947-2)
35kA (440/480Vac; IEC60947-2)
18kA (500/525Vac; IEC60947-2)
Service short circuit current breaking capacity as a percentage of Icu (Ics%)
100 %
Trip unit type
Technology = Thermal-Magnetic (fixed)
Series = TMD
Display = none
Series = TMD
Display = none
Protection functions
Thermal protection (Overload)
Magnetic protection (Short-circuit)
Magnetic protection (Short-circuit)
Protection settings
Over-current -- fixed at 25A
S - Protection against short-circuit hold current -- fixed at 350A
S - Protection against short-circuit trip current -- fixed at 750A
S - Protection against short-circuit hold current -- fixed at 350A
S - Protection against short-circuit trip current -- fixed at 750A
Mounting mode
Individual unit mount on plate
Operating mode
Toggle (manual)
Degree of protection
IP40
Net Height (mm)
163 mm
Net Width (mm)
104 mm
Net Depth (mm)
86 mm
Utilisation category
A
Manufacturer product status
Commercialized
Compliant with standard(s)
EN / IEC (EU/Worldwide)
- CE marking
- EN/IEC 60947-2
- EN/IEC 60947-5-1
United States of America
- UL Listed
- UL 489
- NEMA
Canada
- CSA C22.2 No 5
Mexico
- NOM
- NMX J-266
China
- CCC
Marine approvals
- ABS (American Bureau of Shipping)
- CE marking
- EN/IEC 60947-2
- EN/IEC 60947-5-1
United States of America
- UL Listed
- UL 489
- NEMA
Canada
- CSA C22.2 No 5
Mexico
- NOM
- NMX J-266
China
- CCC
Marine approvals
- ABS (American Bureau of Shipping)
Benefits
A flexible high performance offer certified to global standards
Thermal magnetic or MicroLogic trip protection from 15-250A up to 600Vac and 250Vdc
2 and 3-pole unit mount and I-Line constructions
High performance UL listed interrupting ratings from 18 to 200kA at 480Vac
H- and J-Frame have common mounting holes handle locations and trim dimensions with many shared accessories and auxiliaries
UL/CSA/NOM/IEC/CCC certified and CE marked for global acceptance
Thermal magnetic or MicroLogic trip protection from 15-250A up to 600Vac and 250Vdc
2 and 3-pole unit mount and I-Line constructions
High performance UL listed interrupting ratings from 18 to 200kA at 480Vac
H- and J-Frame have common mounting holes handle locations and trim dimensions with many shared accessories and auxiliaries
UL/CSA/NOM/IEC/CCC certified and CE marked for global acceptance
Degree of pollution
3