Schneider Electric
LAL3640031MMotor circuit protector PowerPact LA-Frame 3P 400A 600Vac 22kA lugs 80% rated
Motor circuit protector PowerPact LA-Frame 3P 400A 600Vac 22kA lugs 80% rated
Electronic Motor Protector Circuit Breaker (MPCB) / Manual Motor Starter / Motor Circuit Protector (MCP) - PowerPact LA-Frame 600 TMD 3P 400A 600Vac 22kA lugs - 80% rated - Square D by Schneider Electric - 3-poles (3P) - Rated current 400A - Rated voltage 600Vac - Short circuit breaking capacity 22kA (600Y/347Vac; UL489) - Thermal-Magnetic (adjustable) (TMD) trip unit - Lugs on both load and line sides
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
LAL3640031M
Online Price
$4,619.00
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
LAL3640031MSchneider Electric - PowerPacT LA-Frame - PowerPacT LAL
Description
Electronic Motor Protector Circuit Breaker (MPCB) / Manual Motor Starter / Motor Circuit Protector (MCP) - PowerPact LA-Frame 600 TMD 3P 400A 600Vac 22kA lugs - 80% rated - Square D by Schneider Electric - 3-poles (3P) - Rated current 400A - Rated voltage 600Vac - Short circuit breaking capacity 22kA (600Y/347Vac; UL489) - Thermal-Magnetic (adjustable) (TMD) trip unit - Lugs on both load and line sides
Specifications
Primary brand
Square D by Schneider Electric
Main function
Motor Protection Circuit Breaker (MPCB)
Product series / family name
PowerPacT LA-Frame motor protectors
Sub-range name
PowerPacT LAL
Functions
Electronic Motor Protector Circuit Breaker (MPCB) / Manual Motor Starter / Motor Circuit Protector (MCP)
Design
PowerPact LA-Frame 600 TMD 3P 400A 600Vac 22kA lugs
80% rated
80% rated
Poles
3-poles (3P)
Rated current
400A
Trip current rating
400 AT
Frame current rating
600 AF
Rated operating voltage (Ue)
600 V
Rated Voltage (DC)
250Vdc
Rated voltage (AC)
600Vac
600Y/347Vac
600Y/347Vac
Rated impulse voltage (Uimp)
8 kV
Rated insulation voltage (Ui)
750 V
Connection type
Lugs on both load and line sides
Short circuit breaking rating
42kA (240Vac; UL489)
30kA (480Vac; UL489)
30kA (480Y/277Vac; UL489)
22kA (600Vac; UL489)
22kA (600Y/347Vac; UL489)
10kA (250Vdc; UL489)
30kA (480Vac; UL489)
30kA (480Y/277Vac; UL489)
22kA (600Vac; UL489)
22kA (600Y/347Vac; UL489)
10kA (250Vdc; UL489)
Ultimate short circuit current breaking capacity (Icu)
20kA (380Vac/400Vac/415Vac; IEC60947-2)
Service short circuit current breaking capacity (Ics)
5kA (380/415Vac; IEC60947-2)
Trip unit type
Technology = Thermal-Magnetic (adjustable)
Series = TMD
Display = none
Series = TMD
Display = none
Protection functions
Thermal protection (Overload)
Magnetic protection (Short-circuit)
Magnetic protection (Short-circuit)
Protection settings
Over-current -- fixed at 400A
Short-circuit pickup current -- adjustable 1125A...2250A
Short-circuit pickup current -- adjustable 1125A...2250A
Mounting mode
Individual unit mount on plate
Operating mode
Toggle (manual)
Degree of protection
IP40
Net Height (mm)
280 mm
Net Width (mm)
153 mm
Net Depth (mm)
150 mm
Utilisation category
A
Manufacturer product status
Commercialized
UPC code
785901358381
Compliant with standard(s)
EN / IEC (EU/Worldwide)
- CE marking
- EN/IEC 60947-2
United States of America
- UL Listed
- UL 489
- NEMA
Canada
- CSA C22.2 No 5
Mexico
- NOM
- CE marking
- EN/IEC 60947-2
United States of America
- UL Listed
- UL 489
- NEMA
Canada
- CSA C22.2 No 5
Mexico
- NOM
Benefits
Thermal magnetic protection from 125-400A up to 600Vac and 250Vdc
2-pole and 3-pole unit mount and I-Line constructions
UL listed interrupting ratings from 30kA to 35kA at 480Vac
UL/CSA and IEC certified
2-pole and 3-pole unit mount and I-Line constructions
UL listed interrupting ratings from 30kA to 35kA at 480Vac
UL/CSA and IEC certified
Degree of pollution
3
Related Documents
Name | Last Update | Language |
---|---|---|
Schneider Electric - PowerPacT MCCB-B-H-J-Q-frame - Catalogue.pdf | 31 Oct 2023 | English (US) |