Schneider Electric
LHL36400Circuit breaker PowerPacT LH-Frame 3P 400A 600Vac 25kA lugs 80% rated
Circuit breaker PowerPacT LH-Frame 3P 400A 600Vac 25kA lugs 80% rated
Moulded Case Circuit Breaker (MCCB) - PowerPact LH-Frame High-interrupting 600 TMD 3P 400A 600Vac 25kA lugs - 80% rated - Square D by Schneider Electric - 3-poles (3P) - Rated current 400A - Rated voltage 600Vac - Short circuit breaking capacity 25kA (600Y/347Vac; UL489) - Thermal-Magnetic (adjustable) (TMD) trip unit - Lugs on both load and line sides
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
LHL36400
Online Price
$7,598.00
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Schneider Electric - PowerPacT LH-Frame High-interrupting - PowerPacT LHLLHL36400
Description
Moulded Case Circuit Breaker (MCCB) - PowerPact LH-Frame High-interrupting 600 TMD 3P 400A 600Vac 25kA lugs - 80% rated - Square D by Schneider Electric - 3-poles (3P) - Rated current 400A - Rated voltage 600Vac - Short circuit breaking capacity 25kA (600Y/347Vac; UL489) - Thermal-Magnetic (adjustable) (TMD) trip unit - Lugs on both load and line sides
Specifications
Primary brand
Square D by Schneider Electric
Main function
Moulded Case Circuit Breaker (MCCB)
Product series / family name
PowerPacT LH-Frame (High-interrupting) complete breakers
Sub-range name
PowerPacT LHL
Functions
Moulded Case Circuit Breaker (MCCB)
Design
PowerPact LH-Frame High-interrupting 600 TMD 3P 400A 600Vac 25kA lugs
80% rated
80% rated
Poles
3-poles (3P)
Rated current
400A
Trip current rating
400 AT
Frame current rating
600 AF
Rated operating voltage (Ue)
600 V
Rated Voltage (DC)
250Vdc
Rated voltage (AC)
600Vac
600Y/347Vac
600Y/347Vac
Rated impulse voltage (Uimp)
8 kV
Rated insulation voltage (Ui)
750 V
Connection type
Lugs on both load and line sides
Short circuit breaking rating
65kA (240Vac; UL489)
35kA (480Vac; UL489)
35kA (480Y/277Vac; UL489)
25kA (600Vac; UL489)
25kA (600Y/347Vac; UL489)
50kA (250Vdc; UL489)
20kA (500Vdc; UL489)
35kA (480Vac; UL489)
35kA (480Y/277Vac; UL489)
25kA (600Vac; UL489)
25kA (600Y/347Vac; UL489)
50kA (250Vdc; UL489)
20kA (500Vdc; UL489)
Ultimate short circuit current breaking capacity (Icu)
20kA (380Vac/400Vac/415Vac; IEC60947-2)
Service short circuit current breaking capacity (Ics)
5kA (380/220Vac; IEC60947-2)
Trip unit type
Technology = Thermal-Magnetic (adjustable)
Series = TMD
Display = none
Series = TMD
Display = none
Protection functions
Thermal protection (Overload)
Magnetic protection (Short-circuit)
Magnetic protection (Short-circuit)
Protection settings
Over-current -- fixed at 400A
Short-circuit pickup current -- adjustable 2000A...4000A
Short-circuit pickup current -- adjustable 2000A...4000A
Mounting mode
Individual unit mount on plate
Operating mode
Toggle (manual)
Degree of protection
IP40
Net Height (mm)
280 mm
Net Width (mm)
153 mm
Net Depth (mm)
150 mm
Utilisation category
A
Manufacturer product status
Commercialized
Compliant with standard(s)
EN / IEC (EU/Worldwide)
- CE marking
- EN/IEC 60947-2
- EN/IEC 60947-5-1
United States of America
- UL Listed
- UL 489
- NEMA
Canada
- CSA C22.2 No 5
Mexico
- NOM
- NMX J-266
- CE marking
- EN/IEC 60947-2
- EN/IEC 60947-5-1
United States of America
- UL Listed
- UL 489
- NEMA
Canada
- CSA C22.2 No 5
Mexico
- NOM
- NMX J-266
Benefits
Thermal magnetic protection from 125-400A up to 600Vac and 250Vdc
2-pole and 3-pole unit mount and I-Line constructions
UL listed interrupting ratings from 30kA to 35kA at 480Vac
UL/CSA and IEC certified
2-pole and 3-pole unit mount and I-Line constructions
UL listed interrupting ratings from 30kA to 35kA at 480Vac
UL/CSA and IEC certified
Degree of pollution
3