Schneider Electric
LTMEV40BD
Intelligent (Programmable) Motor Protection Relay accessory - Schneider Electric (LTMR (TeSys T)) - extension module LTME TeSys T - 24 V DC
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
LTMEV40BD
Online Price
$300.00
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
TeSysTeSys LTMR (TeSys T)
Description
Intelligent (Programmable) Motor Protection Relay accessory - Schneider Electric (LTMR (TeSys T)) - extension module LTME TeSys T - 24 V DC
Specifications
Primary brand
Schneider Electric
Secondary brand
Telemecanique
Product series / family name
TeSys
Sub-range name
LTMR (TeSys T)
Functions
(Fault statistics) Protection fault counters
(Fault statistics) Protection alarm counters
(Fault statistics) Diagnostic fault counters
(Fault statistics) Motor control function counters
(Fault statistics) Motor control function counters
(Fault statistics) Fault history
(Fault diagnostics) Internal watchdog fault
(Fault diagnostics) Controller internal temperature
(Fault diagnostics) Temperature sensor connection
(Fault diagnostics) Current connection
(Fault diagnostics) Voltage connection
(Fault diagnostics) Motor control commands (start; stop; run check back and stock check back)
(Fault diagnostics) Control configuration checksum
(Fault diagnostics) Loss of communication
(Motor statistics) Number of motor control commands (O.1/O.2 starts)
(Motor statistics) Operating time
(Motor statistics) Number of starts/hour
(Motor statistics) Last start I max.
(Motor statistics) Duration of last start
(Thermal overload statistics) Time to trip
(Thermal overload statistics) Time to restart
(System operating statistics) Run; On; Start; alarm; fault
(Fault statistics) Protection alarm counters
(Fault statistics) Diagnostic fault counters
(Fault statistics) Motor control function counters
(Fault statistics) Motor control function counters
(Fault statistics) Fault history
(Fault diagnostics) Internal watchdog fault
(Fault diagnostics) Controller internal temperature
(Fault diagnostics) Temperature sensor connection
(Fault diagnostics) Current connection
(Fault diagnostics) Voltage connection
(Fault diagnostics) Motor control commands (start; stop; run check back and stock check back)
(Fault diagnostics) Control configuration checksum
(Fault diagnostics) Loss of communication
(Motor statistics) Number of motor control commands (O.1/O.2 starts)
(Motor statistics) Operating time
(Motor statistics) Number of starts/hour
(Motor statistics) Last start I max.
(Motor statistics) Duration of last start
(Thermal overload statistics) Time to trip
(Thermal overload statistics) Time to restart
(System operating statistics) Run; On; Start; alarm; fault
Protection settings
(Phase imbalance) 0-15% - 0.2-20s
(Phase failure) 0.1-30s
(Phase reversal) A-B-C
(Phase reversal) A-C-B
(Voltage variation) Minimum 70-99% - 0.2-25s
(Voltage variation) Maximum 101-115% - 0.2-25s
(Load shedding) 68-115% - 1-9999s
(Power variations) 20-800% - 1-100s
(Variation of Cos phi) 0-1s - 1-25s
(Phase failure) 0.1-30s
(Phase reversal) A-B-C
(Phase reversal) A-C-B
(Voltage variation) Minimum 70-99% - 0.2-25s
(Voltage variation) Maximum 101-115% - 0.2-25s
(Load shedding) 68-115% - 1-9999s
(Power variations) 20-800% - 1-100s
(Variation of Cos phi) 0-1s - 1-25s
Supply voltage
(DC) 24 V
Manufacturer product status
Commercialized
Rated Voltage (AC) - Phase-to-phase
690 V
Compliant with standard(s)
EN 60947-4-1
IACS E10
IEC 60947-4-1
UL 508
CSA C22.2 No 14
IACS E10
IEC 60947-4-1
UL 508
CSA C22.2 No 14
Connection type
3 measurement current transformers
(control circuit) Screw-clamp
(control circuit) Screw-clamp
Protection functions
Phase to balance (1 alarm; 1 trip) monitors the symmetry of voltage between phases. To be used for imbalance < 40 % of the average voltage.
Phase failure (1 alarm; 1 trip) monitors the symmetry of voltage between phases. To be used for imbalance > 40 % of the average voltage.
Phase reversal (1 trip) signals when the phase sequence is different from the defied sequence (motor stopped).
Voltage variation (1 alarm; 1 trip) Min/max voltage limits; monitors voltage variations around preset thresholds.
Load shedding; opens outputs O.1 and O.2 if voltage drops below a preset threshold.
Power variation (1 alarm; 1 trip) Min/max power limits; monitors power variations around preset thresholds.
Variations of Cos phi (1 alarm; 1 trip) Min/max limits of Cos phi; monitors variations of Cos phi around preset thresholds.
Phase failure (1 alarm; 1 trip) monitors the symmetry of voltage between phases. To be used for imbalance > 40 % of the average voltage.
Phase reversal (1 trip) signals when the phase sequence is different from the defied sequence (motor stopped).
Voltage variation (1 alarm; 1 trip) Min/max voltage limits; monitors voltage variations around preset thresholds.
Load shedding; opens outputs O.1 and O.2 if voltage drops below a preset threshold.
Power variation (1 alarm; 1 trip) Min/max power limits; monitors power variations around preset thresholds.
Variations of Cos phi (1 alarm; 1 trip) Min/max limits of Cos phi; monitors variations of Cos phi around preset thresholds.
Measurement function
(Measurement) Frequency 0-100Hz
(Measurement) Voltage between phases 0-830V
(Measurement) Voltage imbalance between phases 0-200%
(Measurement) Active power 0-6553.5kW
(Measurements) Reactive power 0-6553.5 kVAr
(Measurements) Cos phi (power factor) 0-100
(Measurements) Active power consumption 0-400kWh
(Measurements) Reactive power consumption 0-400kVArh
(Measurement) Voltage between phases 0-830V
(Measurement) Voltage imbalance between phases 0-200%
(Measurement) Active power 0-6553.5kW
(Measurements) Reactive power 0-6553.5 kVAr
(Measurements) Cos phi (power factor) 0-100
(Measurements) Active power consumption 0-400kWh
(Measurements) Reactive power consumption 0-400kVArh
Related Documents
Name | Last Update | Language |
---|---|---|
Motor Protections - Schneider Electric (TeSys T) - Catalogue pages | 01 Nov 2016 | English (US) |