Schneider Electric
METSEPM2130
Digital Power Meter - Schneider Electric (PM2000 series) - PM2110 - LED display - THD; Cl.0.5s - Modbus communication - 31st harmonic measurement - Datalogger
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
METSEPM2130
Online Price
$866.55
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
PowerLogic
Description
Digital Power Meter - Schneider Electric (PM2000 series) - PM2110 - LED display - THD; Cl.0.5s - Modbus communication - 31st harmonic measurement - Datalogger
Specifications
Primary brand
Schneider Electric
Secondary brand
Merlin Gerin
Product series / family name
PowerLogic
Sub-range name
PM2000
Network frequency
45-65 Hz
Sampling rate
(64 samples/cycle; 50Hz) 3 200 Hz
(64 samples/cycle; 60Hz) 3 840 Hz
(64 samples/cycle; 60Hz) 3 840 Hz
Communication protocol
Modbus RTU
Measurement accuracy
0.05% frequency
0.5% current
0.01% power factor
0.5% voltage
0.5% active power
1% reactive energy
0.5% active energy
0.5% apparent power
0.5% current
0.01% power factor
0.5% voltage
0.5% active power
1% reactive energy
0.5% active energy
0.5% apparent power
Degree of protection
IP30 (body) conforming to IEC 60529
IP51 (front) conforming to IEC 60529
IP51 (front) conforming to IEC 60529
Net Height (mm)
96 mm
Net Width (mm)
96 mm
Ambient air temperature for operation
-10/+60 °C
Display type
7 segments LED
Power consumption
8 VA
Compliant with standard(s)
IEC61010-1
IEC61000-4-11
IEC61000-4-8
IEC61000-4-6
IEC61000-4-5
IEC61000-4-4
IEC61000-4-3
IEC61000-4-2
FCC part 15 Class A
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-Tick
IEC61000-4-11
IEC61000-4-8
IEC61000-4-6
IEC61000-4-5
IEC61000-4-4
IEC61000-4-3
IEC61000-4-2
FCC part 15 Class A
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-Tick
Mounting mode
Flush mounting
Embedding depth
61.64 mm
Degree of pollution
2
Measurement function
Power factor (average)
Frequency (average)
Voltage (Phase-Phase; Phase-Neutral)
Current (Phase average)
Calculated neutral current
Active and reactive power (total)
Apparent power (total)
Accumulated Active; Reactive and Apparent Energy (Total; signed or four-quadrant)
Total voltage harmonic distortion THD (U) (per phase)
Total current harmonic distortion THD (I) (per phase)
Demand current I1; I2; I3(Peak)
Active power P; P1; P2; P3
Reactive power Q; Q1; Q2; Q3
Apparent power S; S1; S2; S3
Demand power P; Q; S(Peak)
Unbalance current
Up to the 31st harmonic
Frequency (average)
Voltage (Phase-Phase; Phase-Neutral)
Current (Phase average)
Calculated neutral current
Active and reactive power (total)
Apparent power (total)
Accumulated Active; Reactive and Apparent Energy (Total; signed or four-quadrant)
Total voltage harmonic distortion THD (U) (per phase)
Total current harmonic distortion THD (I) (per phase)
Demand current I1; I2; I3(Peak)
Active power P; P1; P2; P3
Reactive power Q; Q1; Q2; Q3
Apparent power S; S1; S2; S3
Demand power P; Q; S(Peak)
Unbalance current
Up to the 31st harmonic
Accuracy class
Class 0.5S (active energy according to IEC 62053-22)
Class 1 (reactive energy according to IEC 62053-24)
Class 1 (reactive energy according to IEC 62053-24)
Data recording
Time stamping
Min/max for 8 parameters
Power logs
Min/max for 8 parameters
Power logs
Related Documents
Name | Last Update | Language |
---|---|---|
Schneider Electric - PowerLogic digital meter & systems - Catalogue.pdf | 31 Aug 2018 | English (US) |