Schneider Electric
METSEPM5560
Digital Power Meter - Schneider Electric (PM5500) - PM5560 powermeter w 1mod2eth - up to 63th harmonic - 1.1MBytes memory - 4DI/2DO - 52alarms - flush mount
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
METSEPM5560
Online Price
$3,574.35
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
PowerLogic
Description
Digital Power Meter - Schneider Electric (PM5500) - PM5560 powermeter w 1mod2eth - up to 63th harmonic - 1.1MBytes memory - 4DI/2DO - 52alarms - flush mount
Specifications
Primary brand
Schneider Electric
Secondary brand
Merlin Gerin
Product series / family name
PowerLogic
Sub-range name
PM5500
Network frequency
45-65 Hz
Functions
I/O timer
Operating timer
Active load timer
Alarm counters
Alarm logs
Alarms with 1s resolution timestamping
Ethernet-to-serial gateway
Onboard web-server with web pages
Operating timer
Active load timer
Alarm counters
Alarm logs
Alarms with 1s resolution timestamping
Ethernet-to-serial gateway
Onboard web-server with web pages
Type of network
1P+N
3P
3P+N
3P
3P+N
Sampling rate
(128 samples/cycle; 50Hz) 6 400 Hz
(128 samples/cycle; 60Hz) 7 680 Hz
(128 samples/cycle; 60Hz) 7 680 Hz
Memory capacity
1.1 MB
Communication protocol
Modbus
2 Ethernet (Modbus TCP and BacNet TCP simultaneous) ports
2 Ethernet (Modbus TCP and BacNet TCP simultaneous) ports
Measurement accuracy
0.05% frequency
0.5% current
0.5% voltage(Phase-Neutral)
0.5% active power
0.5% apparent power
0.5% active energy
2% reactive energy
0.5% current
0.5% voltage(Phase-Neutral)
0.5% active power
0.5% apparent power
0.5% active energy
2% reactive energy
Degree of protection
IP30 (body) conforming to IEC 60529
IP52 (front) conforming to IEC 60529
IP52 (front) conforming to IEC 60529
Net Height (mm)
96 mm
Net Width (mm)
96 mm
Door cut-out height
(+0.03 / +0.8) 92 mm
Door cut-out width
(+0.03 / +0.8) 92 mm
Ambient air temperature for operation
-25/+70 °C
Display type
White backlit LCD
Monochrome Graphics LCD
6 lines
4 values
Monochrome Graphics LCD
6 lines
4 values
Power consumption
10 VA
(CT burden at 10A) 0.024 VA
(CT burden at 10A) 0.024 VA
Contacts type
(Digital outputs) SPDT (Single Pole Double Throw)
Primary current
(Selectable CT rating) 1-32767 A
Secondary current
(CT secondary current) 1 A
(CT secondary current) 5 A
(CT secondary current) 5 A
Resistance
(VT input impedance) 5M Ω
(Current input impedance) 0.3milli Ω
(Current input impedance) 0.3milli Ω
Compliant with standard(s)
EN50470-1
EN50470-3
BTL
IEC60529
IEC61010-1
IEC61557-12
IEC62053-22
IEC62053-24
IEC61000-4-11
IEC61000-4-8
IEC61000-4-6
IEC61000-4-5
IEC61000-4-4
IEC61000-4-3
IEC61000-4-2
FCC part 15 Class B
UL61010-1
EN50470-3
BTL
IEC60529
IEC61010-1
IEC61557-12
IEC62053-22
IEC62053-24
IEC61000-4-11
IEC61000-4-8
IEC61000-4-6
IEC61000-4-5
IEC61000-4-4
IEC61000-4-3
IEC61000-4-2
FCC part 15 Class B
UL61010-1
Mounting mode
Flush mounting
Embedding depth
44 mm
Degree of pollution
2
Measurement function
Power factor (signed / four quadrant)
Frequency
Voltage (total; per phase; Phase-Phase; Phase-Neutral)
Current (Phase; Neutral; Ground)
Current average (Present; Last; Predicted; Peak; & Peak Date Time)
Accumulated Active; Reactive and Apparent Energy (Received/Delivered; Net and absolute; Time Counters)
Total Demand Distorsion (TDD)
Total voltage harmonic distortion THD;thd (U) (V L-N; V L-L per phase)
Total voltage harmonic distortion THD;thd (I)
Demand current average (Present; Last; Predicted; Peak; and Peak Date Time)
Real/active power (Total or per-phase; signed or four-quadrant)
Reactive power (Total or per-phase; signed or four-quadrant)
Apparent power (Total or per-phase; signed or four-quadrant)
Demand power P; Q; S (Present; Last; Predicted; Peak; and Peak Date Time)
%Unbalanced I; V L-N; V L-L
Up to the 63rd harmonic
Multi-tariff
8 tariffs
True power factor (Total or per-phase; signed / four quadrant)
Displacement PF (Total or per-phase; signed / four quadrant)
Peak demand with timestamping (day + time) or current and powers
Demand calculation Sliding; fixed and rolling block; thermal
Synchronization of the measurement window
Settable Demand intervals
Demand calculation for Pulse input (WAGES)
Frequency
Voltage (total; per phase; Phase-Phase; Phase-Neutral)
Current (Phase; Neutral; Ground)
Current average (Present; Last; Predicted; Peak; & Peak Date Time)
Accumulated Active; Reactive and Apparent Energy (Received/Delivered; Net and absolute; Time Counters)
Total Demand Distorsion (TDD)
Total voltage harmonic distortion THD;thd (U) (V L-N; V L-L per phase)
Total voltage harmonic distortion THD;thd (I)
Demand current average (Present; Last; Predicted; Peak; and Peak Date Time)
Real/active power (Total or per-phase; signed or four-quadrant)
Reactive power (Total or per-phase; signed or four-quadrant)
Apparent power (Total or per-phase; signed or four-quadrant)
Demand power P; Q; S (Present; Last; Predicted; Peak; and Peak Date Time)
%Unbalanced I; V L-N; V L-L
Up to the 63rd harmonic
Multi-tariff
8 tariffs
True power factor (Total or per-phase; signed / four quadrant)
Displacement PF (Total or per-phase; signed / four quadrant)
Peak demand with timestamping (day + time) or current and powers
Demand calculation Sliding; fixed and rolling block; thermal
Synchronization of the measurement window
Settable Demand intervals
Demand calculation for Pulse input (WAGES)
Accuracy class
IEC 61557-12 PMD/[SD/SS]/K70/0.2
Class 0.2S (active energy according to IEC 62053-22)
Class 0.2 (active energy according to ANSI C12.20)
Class 2 (reactive energy according to IEC 62053-23)
Class 0.2S (active energy according to IEC 62053-22)
Class 0.2 (active energy according to ANSI C12.20)
Class 2 (reactive energy according to IEC 62053-23)
Data recording
non-volatile memory
Up to 14 selectable parameters with configurable interval and duration (e.g. 6 parameters for 90 days at 15 minutes interval)
Alarms time stamping (1s resolution)
(Data recording) Min/max of instantaneous values; plus phase identification
Min/max of instantaneous values
Maintenance/Alarm/Event logs
Up to 14 selectable parameters with configurable interval and duration (e.g. 6 parameters for 90 days at 15 minutes interval)
Alarms time stamping (1s resolution)
(Data recording) Min/max of instantaneous values; plus phase identification
Min/max of instantaneous values
Maintenance/Alarm/Event logs
Related Documents
Name | Last Update | Language |
---|---|---|
Schneider Electric - PowerLogic digital meter & systems - Catalogue.pdf | 31 Aug 2018 | English (US) |