Schneider Electric
METSEPM5563
Digital Power Meter - Schneider Electric (PM5500) - PM5563 powermeter w 1mod2eth - up to 63th harmonic - 1.1MBytes memory - 4DI/2DO - 52alarms - DIN mount
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
METSEPM5563
Online Price
$2,834.46
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
PowerLogic
Description
Digital Power Meter - Schneider Electric (PM5500) - PM5563 powermeter w 1mod2eth - up to 63th harmonic - 1.1MBytes memory - 4DI/2DO - 52alarms - DIN mount
Specifications
Primary brand
Schneider Electric
Secondary brand
Merlin Gerin
Product series / family name
PowerLogic
Sub-range name
PM5500
Network frequency
45-65 Hz
Functions
I/O timer
Operating timer
Active load timer
Alarm counters
Alarm logs
Alarms with 1s resolution timestamping
Ethernet-to-serial gateway
Onboard web-server with web pages
Operating timer
Active load timer
Alarm counters
Alarm logs
Alarms with 1s resolution timestamping
Ethernet-to-serial gateway
Onboard web-server with web pages
Type of network
1P+N
3P
3P+N
3P
3P+N
Sampling rate
(128 samples/cycle; 50Hz) 6 400 Hz
(128 samples/cycle; 60Hz) 7 680 Hz
(128 samples/cycle; 60Hz) 7 680 Hz
Memory capacity
1.1 MB
Communication protocol
Modbus
2 Ethernet (Modbus TCP and BacNet TCP simultaneous) ports
2 Ethernet (Modbus TCP and BacNet TCP simultaneous) ports
Measurement accuracy
0.05% frequency
0.15% current
0.1% voltage (Phase-Neutral)
0.2% active power
0.5% apparent power
0.2% active energy
1% reactive energy
0.15% current
0.1% voltage (Phase-Neutral)
0.2% active power
0.5% apparent power
0.2% active energy
1% reactive energy
Degree of protection
IP30 (body) conforming to IEC 60529
Door cut-out height
(+0.03 / +0.8) 92 mm
Door cut-out width
(+0.03 / +0.8) 92 mm
Ambient air temperature for operation
-25/+70 °C
Power consumption
10 VA
(CT burden at 10A) 0.024 VA
(CT burden at 10A) 0.024 VA
Contacts type
(Digital outputs) SPDT (Single Pole Double Throw)
Primary current
(Selectable CT rating) 1-32767 A
Secondary current
(CT secondary current) 1 A
(CT secondary current) 5 A
(CT secondary current) 5 A
Resistance
(VT input impedance) 5M Ω
(Current input impedance) 0.3milli Ω
(Current input impedance) 0.3milli Ω
Compliant with standard(s)
EN50470-1
EN50470-3
BTL
IEC60529
IEC61010-1
IEC61557-12
IEC62053-22
IEC62053-24
IEC61000-4-11
IEC61000-4-8
IEC61000-4-6
IEC61000-4-5
IEC61000-4-4
IEC61000-4-3
IEC61000-4-2
FCC part 15 Class B
UL61010-1
EN50470-3
BTL
IEC60529
IEC61010-1
IEC61557-12
IEC62053-22
IEC62053-24
IEC61000-4-11
IEC61000-4-8
IEC61000-4-6
IEC61000-4-5
IEC61000-4-4
IEC61000-4-3
IEC61000-4-2
FCC part 15 Class B
UL61010-1
Mounting mode
DIN rail
Degree of pollution
2
Measurement function
Power factor (signed / four quadrant)
Frequency
Voltage (total; per phase; Phase-Phase; Phase-Neutral)
Current (Phase; Neutral; Ground)
Current average (Present; Last; Predicted; Peak; & Peak Date Time)
Accumulated Active; Reactive and Apparent Energy (Received/Delivered; Net and absolute; Time Counters)
Total Demand Distorsion (TDD)
Total voltage harmonic distortion THD;thd (U) (V L-N; V L-L per phase)
Total voltage harmonic distortion THD;thd (I)
Demand current average (Present; Last; Predicted; Peak; and Peak Date Time)
Real/active power (Total or per-phase; signed or four-quadrant)
Reactive power (Total or per-phase; signed or four-quadrant)
Apparent power (Total or per-phase; signed or four-quadrant)
Demand power P; Q; S (Present; Last; Predicted; Peak; and Peak Date Time)
%Unbalanced I; V L-N; V L-L
Up to the 63rd harmonic
Multi-tariff
8 tariffs
True power factor (Total or per-phase; signed / four quadrant)
Displacement PF (Total or per-phase; signed / four quadrant)
Peak demand with timestamping (day + time) or current and powers
Demand calculation Sliding; fixed and rolling block; thermal
Synchronization of the measurement window
Settable Demand intervals
Demand calculation for Pulse input (WAGES)
Frequency
Voltage (total; per phase; Phase-Phase; Phase-Neutral)
Current (Phase; Neutral; Ground)
Current average (Present; Last; Predicted; Peak; & Peak Date Time)
Accumulated Active; Reactive and Apparent Energy (Received/Delivered; Net and absolute; Time Counters)
Total Demand Distorsion (TDD)
Total voltage harmonic distortion THD;thd (U) (V L-N; V L-L per phase)
Total voltage harmonic distortion THD;thd (I)
Demand current average (Present; Last; Predicted; Peak; and Peak Date Time)
Real/active power (Total or per-phase; signed or four-quadrant)
Reactive power (Total or per-phase; signed or four-quadrant)
Apparent power (Total or per-phase; signed or four-quadrant)
Demand power P; Q; S (Present; Last; Predicted; Peak; and Peak Date Time)
%Unbalanced I; V L-N; V L-L
Up to the 63rd harmonic
Multi-tariff
8 tariffs
True power factor (Total or per-phase; signed / four quadrant)
Displacement PF (Total or per-phase; signed / four quadrant)
Peak demand with timestamping (day + time) or current and powers
Demand calculation Sliding; fixed and rolling block; thermal
Synchronization of the measurement window
Settable Demand intervals
Demand calculation for Pulse input (WAGES)
Accuracy class
IEC 61557-12 PMD/[SD/SS]/K70/0.2
Class 0.2S (active energy according to IEC 62053-22)
Class 0.2 (active energy according to ANSI C12.20)
Class 2 (reactive energy according to IEC 62053-23)
Class 0.2S (active energy according to IEC 62053-22)
Class 0.2 (active energy according to ANSI C12.20)
Class 2 (reactive energy according to IEC 62053-23)
Data recording
non-volatile memory
Up to 14 selectable parameters with configurable interval and duration (e.g. 6 parameters for 90 days at 15 minutes interval)
Alarms time stamping (1s resolution)
(Data recording) Min/max of instantaneous values; plus phase identification
Min/max of instantaneous values
Maintenance/Alarm/Event logs
Up to 14 selectable parameters with configurable interval and duration (e.g. 6 parameters for 90 days at 15 minutes interval)
Alarms time stamping (1s resolution)
(Data recording) Min/max of instantaneous values; plus phase identification
Min/max of instantaneous values
Maintenance/Alarm/Event logs
Related Documents
Name | Last Update | Language |
---|---|---|
Schneider Electric - PowerLogic digital meter & systems - Catalogue.pdf | 31 Aug 2018 | English (US) |