Schneider Electric
METSEPM8244
Digital Power Meter - Schneider Electric (PM8000 series) - PM8244 powermeter - meter - 3DI / 1 pulse outputDO - Colour TFT LCD (remote display) display - Up to the 63rd harmonic
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
METSEPM8244
Online Price
$9,737.57
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
PowerLogic
Description
Digital Power Meter - Schneider Electric (PM8000 series) - PM8244 powermeter - meter - 3DI / 1 pulse outputDO - Colour TFT LCD (remote display) display - Up to the 63rd harmonic
Specifications
Primary brand
Schneider Electric
Secondary brand
Merlin Gerin
Product series / family name
PowerLogic
Sub-range name
PM8000
Network frequency
42-69 Hz
Functions
Ethernet
Type of network
1P + N
3P
3P + N
3P
3P + N
Sampling rate
(256 samples/cycle; 42Hz) 10 752 Hz
(256 samples/cycle; 69Hz) 17 664 Hz
(256 samples/cycle; 69Hz) 17 664 Hz
Memory capacity
512 MB
Communication protocol
Modbus RTU
Ethernet (Modbus TCP/IP daisy chain
(ION 2-wire) 115 kbauds
RSTP 801.1d
DNP3
IEC 61850
Ethernet (Modbus TCP/IP daisy chain
(ION 2-wire) 115 kbauds
RSTP 801.1d
DNP3
IEC 61850
Measurement accuracy
0.1% voltage
0.2% active energy
0.2% active energy
Degree of protection
IP30 (body)
Net Height (mm)
96 mm
Net Width (mm)
96 mm
Net Depth (mm)
77.5 mm
Ambient air temperature for operation
-25/+70 °C
Display type
Colour TFT LCD (remote display)
Power consumption
18-36 VA
(CT burden at 10A) 0.024 VA
(CT burden at 10A) 0.024 VA
Secondary current
(CT secondary current) 1 A
(CT secondary current) 5 A
(CT secondary current) 5 A
Resistance
(VT input impedance) 5M Ω
(Current input impedance) 0.3milli Ω
(Current input impedance) 0.3milli Ω
Compliant with standard(s)
IEC61010-1
IEC62052-11
IEC61557-12
IEC62053-22
IEC62053-24
IEC61000-4-11
IEC61000-4-8
IEC61000-4-6
IEC61000-4-5
IEC61000-4-4
IEC61000-4-3
IEC61000-4-2
FCC part 15 Class A
UL61010-1
CULus conforming to CSA C22.2 No 61010-1
CLC/TR50579
IEC62052-11
IEC61557-12
IEC62053-22
IEC62053-24
IEC61000-4-11
IEC61000-4-8
IEC61000-4-6
IEC61000-4-5
IEC61000-4-4
IEC61000-4-3
IEC61000-4-2
FCC part 15 Class A
UL61010-1
CULus conforming to CSA C22.2 No 61010-1
CLC/TR50579
Mounting mode
Flush mounting
Degree of pollution
2
Measurement function
Power factor (Total / per phase)
Frequency
Voltage
Current
Accumulated Active; Reactive and Apparent Energy
Demand predicted active; reactive; apparent power
Demand active; reactive; apparent power (Present; max. values)
Demand current average (Present; max. values)
Real/active power (Total or per-phase)
Reactive power (Total or per-phase)
Apparent power (Total or per-phase; signed or four-quadrant)
Up to the 63rd harmonic
Synchronization of the measurement window
Demand setting of calculation (Block; sliding)
Frequency
Voltage
Current
Accumulated Active; Reactive and Apparent Energy
Demand predicted active; reactive; apparent power
Demand active; reactive; apparent power (Present; max. values)
Demand current average (Present; max. values)
Real/active power (Total or per-phase)
Reactive power (Total or per-phase)
Apparent power (Total or per-phase; signed or four-quadrant)
Up to the 63rd harmonic
Synchronization of the measurement window
Demand setting of calculation (Block; sliding)
Accuracy class
Class 0.2S (active energy according to IEC 62053-22)
Class 0.2 (active energy according to ANSI C12.20)
Class 0.5S (reactive energy according to IEC 62053-24)
Class 0.2 (current according to IEC 61557-12)
Class 0.2 (voltage according to IEC 61557-12)
Class 0.2 (active power according to IEC 61557-12)
Class 0.5 (power factor according to IEC 61557-12)
Class 0.2 (active energy according to ANSI C12.20)
Class 0.5S (reactive energy according to IEC 62053-24)
Class 0.2 (current according to IEC 61557-12)
Class 0.2 (voltage according to IEC 61557-12)
Class 0.2 (active power according to IEC 61557-12)
Class 0.5 (power factor according to IEC 61557-12)
Data recording
Time stamping
(Data recording) Min/max of instantaneous values
Min/max of instantaneous values
Sequence of event recording
GPS synchronisation
Event logs
Data logs
Sag and swell logs
Harmonics logs
Waveform logs
Trending/forecasting
(Data recording) Min/max of instantaneous values
Min/max of instantaneous values
Sequence of event recording
GPS synchronisation
Event logs
Data logs
Sag and swell logs
Harmonics logs
Waveform logs
Trending/forecasting
Related Documents
Name | Last Update | Language |
---|---|---|
Schneider Electric - PowerLogic digital meter & systems - Catalogue.pdf | 31 Aug 2018 | English (US) |