SolaHD (Sola Hevi-Duty)
SDU500BOFFLINE UPS 500VA 120V DIN B-Series
OFFLINE UPS 500VA 120V DIN B-Series
AC/AC backup Uninterruptible Power Supply (UPS) - Emerson / SolaHD Sola/Hevi-Duty (SDU AC-B series) - OFFLINE UPS 500VA 120V DIN B-Series - Class I Division 2 - Single-phase (1AC) input (120Vac (50Hz/60Hz)) - 500VA rated power - 120Vac output voltage (50Hz or 60Hz) - 300W rated power - screw connections - DIN rail mounting (277mm width) - IP20
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
SDU500B
Online Price
$410.60
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
SDU500BEmerson / SolaHD - SDU AC-B series
Description
AC/AC backup Uninterruptible Power Supply (UPS) - Emerson / SolaHD Sola/Hevi-Duty (SDU AC-B series) - OFFLINE UPS 500VA 120V DIN B-Series - Class I Division 2 - Single-phase (1AC) input (120Vac (50Hz/60Hz)) - 500VA rated power - 120Vac output voltage (50Hz or 60Hz) - 300W rated power - screw connections - DIN rail mounting (277mm width) - IP20
Specifications
Primary brand
Emerson
Secondary brand
SolaHD Sola/Hevi-Duty
Main function
Uninterruptible power supply (UPS)
Product series / family name
SDU AC-B series
Functions
AC/AC backup Uninterruptible Power Supply (UPS)
Battery Module -- Sealed; maintenance-free Lead acid batteries
Battery Module -- Typical Recharge Time 8 hours
Battery -- Typical Back-Up Time At full/half load -- 4.20/14.30min.
Alarm -- ON Battery -- Slow beeping every 10 seconds
Alarm -- Battery Low -- Rapid beeping every second
Alarm -- Overload -- Continuous beeping sound
Battery Module -- Sealed; maintenance-free Lead acid batteries
Battery Module -- Typical Recharge Time 8 hours
Battery -- Typical Back-Up Time At full/half load -- 4.20/14.30min.
Alarm -- ON Battery -- Slow beeping every 10 seconds
Alarm -- Battery Low -- Rapid beeping every second
Alarm -- Overload -- Continuous beeping sound
Supply voltage (AC)
120Vac (50Hz/60Hz)
Type of network
Single-phase (1AC)
Rated power
300W
Rated voltage (AC)
120Vac output voltage (50Hz or 60Hz)
Connection type
screw connections
Cross-section
18AWG...8AWG (screw connections)
Protection functions
Protection -- input -- 10A
Overload protection -- UPS shutdown if overload exceeds 105% of nominal at 20s / 120% at 10s / 130% at 3s; auto-recovery
Short Circuit (Utility Mode) -- input fuse will break / UPS goes to battery mode and goes on battery mode short circuit protection until OSCP is removed
Short-circuit (Battery Mode) -- Retry until the short circuit is removed or battery defect
Overload protection -- UPS shutdown if overload exceeds 105% of nominal at 20s / 120% at 10s / 130% at 3s; auto-recovery
Short Circuit (Utility Mode) -- input fuse will break / UPS goes to battery mode and goes on battery mode short circuit protection until OSCP is removed
Short-circuit (Battery Mode) -- Retry until the short circuit is removed or battery defect
Mounting mode
DIN rail mounting
Degree of protection
IP20
Net Height (mm)
124.2 mm
Net Width (mm)
277 mm
Net Depth (mm)
132.7 mm
Ambient air temperature for operation
0...+50 °C
(hazardous environment) 0...+40 °C
(hazardous environment) 0...+40 °C
Rated apparent power (S)
500VA
Power factor (cos phi)
0.6
Manufacturer product status
Commercialized
Compliant with standard(s)
CE marking (Low Voltage Directive EN62040-1 / EMC Directive EN62040-2 EN55032; EN 55011; EN 55024; EN 61000-6-1; EN 61000-6-2; EN 61000-6-3; EN 61000-6-4; EN 61326-1; EN61000-3-2; EN 61000-3-3; IEC/EN 61000-4 Series)
cRUus UL Recognized Component UPS Equipment (UL 1778 5th Ed.; CSA C22.2 No. 107.3 / Suitable for UL 508 at full load output (no derating) and Ind. Control Equipment Applications Overvoltage Cat III Pollution Degree III)
cRUus UL Recognized Component Hazardous Locations (ANSI ISA 12.12.01/CSA 213 Class I Division 2 Groups A; B; C; D; T4)
RoHS
ODVA Compliant -- EtherNet/IP SDUENETIPCARD has been tested and approved for conformance by the ODVA. More information about EtherNet/IP and the ODVA can be obtained from www.odva.org
cRUus UL Recognized Component UPS Equipment (UL 1778 5th Ed.; CSA C22.2 No. 107.3 / Suitable for UL 508 at full load output (no derating) and Ind. Control Equipment Applications Overvoltage Cat III Pollution Degree III)
cRUus UL Recognized Component Hazardous Locations (ANSI ISA 12.12.01/CSA 213 Class I Division 2 Groups A; B; C; D; T4)
RoHS
ODVA Compliant -- EtherNet/IP SDUENETIPCARD has been tested and approved for conformance by the ODVA. More information about EtherNet/IP and the ODVA can be obtained from www.odva.org
Class
Class I Division 2
Benefits
Lightweight; compact industrial design
Communications port for optional Industrial Ethernet protocols or discrete communication card
User replaceable batteries
Long-life high-temperature battery
Wide operation temperature range from 0°C...+50°C (+32°F...+122°F)
Cold start capability
Software and cable included for easy installation
Simulated sinewave output
USB communication port
Remote turn-on and shutdown capabilities
2-year limited warranty
Panel/wall mounting brackets (optional)
Communications port for optional Industrial Ethernet protocols or discrete communication card
User replaceable batteries
Long-life high-temperature battery
Wide operation temperature range from 0°C...+50°C (+32°F...+122°F)
Cold start capability
Software and cable included for easy installation
Simulated sinewave output
USB communication port
Remote turn-on and shutdown capabilities
2-year limited warranty
Panel/wall mounting brackets (optional)
Net width (in)
10.91 in
Net Height (in)
4.89 in
Application type
Programmable logic controllers
Factory automation
Robotics
Conveying equipment
Computer-based control systems
Factory automation
Robotics
Conveying equipment
Computer-based control systems
Related Documents
Name | Last Update | Language |
---|---|---|
SolaHD - SDU AC-B series - Catalog.pdf | 30 Jan 2022 | English (US) |