Eaton
SVX0154D1200B10000
Enclosed Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter with start-stop controls; speed pot & HOA switch - Eaton / Cutler-Hammer (SVX) - Rated input voltage (3-phase (3P)) 480Vac - Rated output current 21A (High overload IH) - Rated power 11kW (High overload IH) / 15HP (High overload IH) - Frame size FR5 - UL type 1 / NEMA 1 - with EMI filter - with RS-232 communication capability - with Brake chopper + Non-bypass light kit
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
SVX0154D1200B10000
Please add this item to cart to request a quote.
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Eaton - SVXSVX0154D1200B10000
Description
Enclosed Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter with start-stop controls; speed pot & HOA switch - Eaton / Cutler-Hammer (SVX) - Rated input voltage (3-phase (3P)) 480Vac - Rated output current 21A (High overload IH) - Rated power 11kW (High overload IH) / 15HP (High overload IH) - Frame size FR5 - UL type 1 / NEMA 1 - with EMI filter - with RS-232 communication capability - with Brake chopper + Non-bypass light kit
Specifications
Primary brand
Eaton
Secondary brand
Cutler-Hammer
Main function
Variable Speed / Frequency Drive (VSD/VFD) / Inverter
Product series / family name
SVX
Network frequency
(input) 45-66 Hz
(output) 0-320 Hz
(output) 0-320 Hz
Functions
Enclosed Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter with start-stop controls; speed pot & HOA switch
Brake chopper
Non-bypass light kit
Circuit breaker power disconnect
Electronic reversing
DC braking
PID setpoint controller
Critical speed lockout
Current (torque) limit
Adjustable acceleration/deceleration
Linear or S curve accel/decel
Jog at preset speed
Thread/preset speeds
Automatic restart
Coasting motor start
Coast or ramp stop selection
Carrier frequency adjustment
Non-bypass light (white = Power ON; green = RUN; red = FAULT)
Brake chopper
Non-bypass light kit
Circuit breaker power disconnect
Electronic reversing
DC braking
PID setpoint controller
Critical speed lockout
Current (torque) limit
Adjustable acceleration/deceleration
Linear or S curve accel/decel
Jog at preset speed
Thread/preset speeds
Automatic restart
Coasting motor start
Coast or ramp stop selection
Carrier frequency adjustment
Non-bypass light (white = Power ON; green = RUN; red = FAULT)
Supply voltage (AC)
480Vac
Type of network
3-phase input (3P)
Rated current
21A (High overload IH)
Rated active power (kW)
11kW (High overload IH)
Rated power (HP)
15HP (High overload IH)
Protection functions
Phase Rotation Insensitive
Input Phase Loss
Input Overvoltage
Output Short-Circuit
Output Ground Fault
Output Phase Protection
Overtemperature
DC Overvoltage
Drive Overload
Motor Overload
Local/remote keypad
Keypad Lockout
Fault Alarm Output
Built-in Diagnostics
Input Phase Loss
Input Overvoltage
Output Short-Circuit
Output Ground Fault
Output Phase Protection
Overtemperature
DC Overvoltage
Drive Overload
Motor Overload
Local/remote keypad
Keypad Lockout
Fault Alarm Output
Built-in Diagnostics
Communication protocol
RS-232
Operating mode
Frequency control (V/f)
Sensorless vector control
IR and slip compensation
Sensorless vector control
IR and slip compensation
Digital inputs
6 x digital inputs (programmable)
Digital outputs
2 x digital outputs (SPDT Single Pole Double Throw contact type)
1 x digital output (Open collector)
1 x digital output (Open collector)
Analog inputs
2 x analog inputs (0-20mA / 4-20mA / 0-10V DC)
Analog outputs
1 x analog output (0-20mA / 4-20mA / 0-10V DC / 2-10V DC)
Degree of protection
UL type 1
NEMA 1
NEMA 1
Ambient air temperature for operation
0...+40 °C
Ambient air temperature for storage
-40...+60 °C
Technology used in component
EMI filter
Application type
General-purpose drive
Manufacturer product status
Commercialized
Compliant with standard(s)
UL 508C
Benefits
Dual rated for both constant torque (CT) / high overload (IH) and variable torque (VT) / low overload applications
Optional Brake Chopper for external braking applications
High-performance drive option uses an Eaton SPX (IH) drive that allows for increased functionality and performance
Available circuit breaker; motor circuit protector; isolation fusing and surge protection device options to provide input power protection
Optional 3% input and output reactors provide a reduction in voltage and current harmonics on both line and load side
Bypass options include a standard three-contactor design and a reduced voltage soft starter design
Output contactor option provides a means for positive disconnection of the drive output from the motor terminals
MotoRX and dV/dt filter options are used to reduce transients voltages at the motor terminals
Customizable cover control options
Padlockable disconnection
Optional Brake Chopper for external braking applications
High-performance drive option uses an Eaton SPX (IH) drive that allows for increased functionality and performance
Available circuit breaker; motor circuit protector; isolation fusing and surge protection device options to provide input power protection
Optional 3% input and output reactors provide a reduction in voltage and current harmonics on both line and load side
Bypass options include a standard three-contactor design and a reduced voltage soft starter design
Output contactor option provides a means for positive disconnection of the drive output from the motor terminals
MotoRX and dV/dt filter options are used to reduce transients voltages at the motor terminals
Customizable cover control options
Padlockable disconnection
Related Documents
Name | Last Update | Language |
---|---|---|
Eaton - PowerXL M-Max SVX H-Max SPX EGF CFX HCX CPX RGX LCX SPA SPN SPI - Catalogue.pdf | 23 Jun 2020 | English (US) |