Digital temperature controller with rly. main (or ALARM1) output + main analog output + 1 rly. ALARM2 (or cooling) output - 1/16 DIN (48x48mm) - Red Lion (Process controllers T48 temperature controllers series) - with 1 x analog input (Thermocouple types T; E; J; K; R; S; B; N / Pt100 RTDs / 100ms sample period; 300-400ms response time) (Main temperature input; 0.1...1° accuracy) + 1 x analog output (0-20mA / 4-20mA / 0-10Vdc; 1/2800...1/3500 conversion resolution) (Main output) + 1 x digital output (250Vac / 30Vdc; 3A; contact type) (O1 or ALARM1) + 1 x digital output (250Vac / 30Vdc; 3A; contact type) (O2 / ALARM2) - Supply voltage 85-250Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac) - IP65 / NEMA 4X
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
T4810101
Online Price
$343.00
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
T4810101Red Lion - T48
Description
Digital temperature controller with rly. main (or ALARM1) output + main analog output + 1 rly. ALARM2 (or cooling) output - 1/16 DIN (48x48mm) - Red Lion (Process controllers T48 temperature controllers series) - with 1 x analog input (Thermocouple types T; E; J; K; R; S; B; N / Pt100 RTDs / 100ms sample period; 300-400ms response time) (Main temperature input; 0.1...1° accuracy) + 1 x analog output (0-20mA / 4-20mA / 0-10Vdc; 1/2800...1/3500 conversion resolution) (Main output) + 1 x digital output (250Vac / 30Vdc; 3A; contact type) (O1 or ALARM1) + 1 x digital output (250Vac / 30Vdc; 3A; contact type) (O2 / ALARM2) - Supply voltage 85-250Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac) - IP65 / NEMA 4X
Specifications
Primary brand
Red Lion
Main function
Temperature controller (Digital)
Product series / family name
Process controllers
Sub-range name
T48 temperature controllers series
Functions
Digital temperature controller
Design
rly. main (or ALARM1) output
main analog output
1 rly. ALARM2 (or cooling) output
1/16 DIN (48x48mm)
main analog output
1 rly. ALARM2 (or cooling) output
1/16 DIN (48x48mm)
Supply voltage (AC)
85-250Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac)
Digital outputs
1 x digital output (250Vac / 30Vdc; 3A; contact type) (O1 or ALARM1)
1 x digital output (250Vac / 30Vdc; 3A; contact type) (O2 / ALARM2)
1 x digital output (250Vac / 30Vdc; 3A; contact type) (O2 / ALARM2)
Analog inputs
1 x analog input (Thermocouple types T; E; J; K; R; S; B; N / Pt100 RTDs / 100ms sample period; 300-400ms response time) (Main temperature input; 0.1...1° accuracy)
Analog outputs
1 x analog output (0-20mA / 4-20mA / 0-10Vdc; 1/2800...1/3500 conversion resolution) (Main output)
Degree of protection
IP65
NEMA 4X
NEMA 4X
Dimensions
1/16 DIN (W48mm x H48mm / 1.89" x 1.89")
Order code / Manufacturer SKU
T4810101
Manufacturer product status
Phasing out
Product replaced by
PXU31A20
PXU41A20
PXU41A20
Compliant with standard(s)
CE
IEC/EN 61010-1
IEC 60068-2-6 (vibration)
EN 61326-1 immunity to industrial locations
UL recognized
RoHS compliant
IEC/EN 61010-1
IEC 60068-2-6 (vibration)
EN 61326-1 immunity to industrial locations
UL recognized
RoHS compliant
Benefits
PID control with reduced overshoot
On demand auto-tuning of PID control settings
NEMA 4x / IP65 bezel
Dual led displays for simultaneous indication of temperature and setpoint
Status indicators for outputs and control modes
Accepts 10 types of sensor inputs (thermocouple / RTD)
Optional heater current monitor and heater break alarm
Optional dual alarm outputs
Optional two linear DC outputs
Manual/automatic control modes
Setpoint ramping for process startup
Programmable user input (digital) for added flexibility
Sensor error compensation (offset) and break detection
Heating and optional cooling outputs
Parameter security via programmable lockouts
Field replaceable output board (relay / logic / SSR drive)
Optional triac output
Second setpoint setting
Optional remote setpoint input
Optional RS-485 serial communications
PC software available for controller configuration
On demand auto-tuning of PID control settings
NEMA 4x / IP65 bezel
Dual led displays for simultaneous indication of temperature and setpoint
Status indicators for outputs and control modes
Accepts 10 types of sensor inputs (thermocouple / RTD)
Optional heater current monitor and heater break alarm
Optional dual alarm outputs
Optional two linear DC outputs
Manual/automatic control modes
Setpoint ramping for process startup
Programmable user input (digital) for added flexibility
Sensor error compensation (offset) and break detection
Heating and optional cooling outputs
Parameter security via programmable lockouts
Field replaceable output board (relay / logic / SSR drive)
Optional triac output
Second setpoint setting
Optional remote setpoint input
Optional RS-485 serial communications
PC software available for controller configuration
Related Documents
Name | Last Update | Language |
---|---|---|
Red Lion - Industrial Automation Product Guide.pdf | 25 Apr 2021 | English (US) |
Red Lion - T48 P48 TLA Output Board - Product Manual.pdf | 25 Apr 2021 | English (US) |
Red Lion - T48 PID controllers - Datasheet.pdf | 25 Apr 2021 | English (US) |
Red Lion - T48-P48 - Instruction Manual.pdf | 25 Apr 2021 | English (US) |