UB40.241
DC/DC Uninterruptible Power Supply (UPS) control module with external batt. - PULS (DIMENSION UB-series) - 60A (in bfr. mode less than 5s full output voltage) - 24Vdc / 50A output - DC input (18Vdc-30Vdc (24Vdc nom.)) - DIN rail mounting (mm width) - equivalent to #UB40241
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
UB40.241
Online Price
$816.00
Discount
10.0%
Net Price
$734.40
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
UB40.241
Description
DC/DC Uninterruptible Power Supply (UPS) control module with external batt. - PULS (DIMENSION UB-series) - 60A (in bfr. mode less than 5s full output voltage) - 24Vdc / 50A output - DC input (18Vdc-30Vdc (24Vdc nom.)) - DIN rail mounting (mm width) - equivalent to #UB40241
Specifications
Primary brand
PULS
Main function
Uninterruptible Power Supply (UPS)
Product series / family name
DIMENSION series
Sub-range name
UB-series
Functions
DC/DC Uninterruptible Power Supply (UPS) control module
Design
external batt.
Green status LED
Green status LED
Supply voltage (DC)
18Vdc-30Vdc (24Vdc nom.)
Display
"Status" LED
Type of network
DC
Rated current
50A (at 24Vdc; below +50°C)
60A (in bfr. mode less than 5s full output voltage)
40A (at 24Vdc; +50...+60°C)
30A (at 24Vdc; +60...+70°C)
60A (in bfr. mode less than 5s full output voltage)
40A (at 24Vdc; +50...+60°C)
30A (at 24Vdc; +60...+70°C)
Output voltage (DC)
24Vdc
Protection functions
output overvoltage protection (32Vdc max.)
Efficiency
0.993 (24Vdc input)
Mounting mode
DIN rail mounting
Dimensions
W46mm x H124mm x D127mm
Material
Aluminium housing
Ambient air temperature for operation
-25...+70 °C
Current consumption
3.2A (24Vdc input)
4A (24Vdc input)
4A (24Vdc input)
Power dissipation/losses
(24Vdc input; 40A output current; battery mode) 6 W
(24Vdc input; 40A output current; battery mode) 9.9 W
(24Vdc input; 40A output current; battery mode) 9.9 W
Manufacturer product status
Commercialized
Equivalent to
UB40241
Compliant with standard(s)
IEC 61010
UL 61010
VDMA 24364
CE marking
REACH Directive
WEEE Directive
ROHS
UL 61010
VDMA 24364
CE marking
REACH Directive
WEEE Directive
ROHS
Electrical durability
(at 40°C; 20A output; 24Vdc input) 457000 hours
(at 25°C; 20A output; 24Vdc input) 1370000 hours
(at 40°C; 40A output; 24Vdc input) 322000 hours
(at 25°C; 40A output; 24Vdc input) 842000 hours
(at 25°C; 20A output; 24Vdc input) 1370000 hours
(at 40°C; 40A output; 24Vdc input) 322000 hours
(at 25°C; 40A output; 24Vdc input) 842000 hours
Benefits
1-Battery-Concept - Each 12V Battery is Charged and Monitored Separately for Longest Battery Life Matching of Batteries not Necessary
Output is Decoupled from the Input to Separate Load
Circuits into Buffered and Non-buffered Sections
Allows VRLA Battery Sizes Between 12Ah and 200Ah;
Battery Size Selector for Various Battery Sizes
50% BonusPower for up to 5s
Superior Battery Management for Longest Battery Life
Comprehensive Diagnostic and Monitoring Functions
Replace Battery Signal Included
Battery-Low Pre-warning Signal Included
Selectable Buffer Time Limiter
Temperature Controlled Battery Charging
3 years warranty
The UB40.241 is an uninterruptible power supply controller (DC-UPS controller) which is used in combination with a 24V power supply and an external 24V-battery pack to bridge power failures. When the power supply provides sufficient voltages the DC-UPS controller charges the battery. When the power supply voltage fails the energy stored in the battery is released to the DC bus in a regulated process. A unique feature is the battery charger which can balance 2 unmatched batteries and which includes 2 independent battery testers for the 2 12V batteries connected in series. This feature makes matching batteries unnecessary and allows for precise battery charging testing and optimized usage of the battery capacity to achieve the longest battery service life. The device includes various battery diagnostic functions including a battery-low pre-warning signal that ensure a reliable operation of the entire system. Furthermore temperature-controlled charging extends the life of the batteries. It also includes a selectable buffer time limiter as well as Ready Buffering and Replace battery contacts. For safety and maintenance an inhibit-input signal is included to enable phases without enforced buffering.
Output is Decoupled from the Input to Separate Load
Circuits into Buffered and Non-buffered Sections
Allows VRLA Battery Sizes Between 12Ah and 200Ah;
Battery Size Selector for Various Battery Sizes
50% BonusPower for up to 5s
Superior Battery Management for Longest Battery Life
Comprehensive Diagnostic and Monitoring Functions
Replace Battery Signal Included
Battery-Low Pre-warning Signal Included
Selectable Buffer Time Limiter
Temperature Controlled Battery Charging
3 years warranty
The UB40.241 is an uninterruptible power supply controller (DC-UPS controller) which is used in combination with a 24V power supply and an external 24V-battery pack to bridge power failures. When the power supply provides sufficient voltages the DC-UPS controller charges the battery. When the power supply voltage fails the energy stored in the battery is released to the DC bus in a regulated process. A unique feature is the battery charger which can balance 2 unmatched batteries and which includes 2 independent battery testers for the 2 12V batteries connected in series. This feature makes matching batteries unnecessary and allows for precise battery charging testing and optimized usage of the battery capacity to achieve the longest battery service life. The device includes various battery diagnostic functions including a battery-low pre-warning signal that ensure a reliable operation of the entire system. Furthermore temperature-controlled charging extends the life of the batteries. It also includes a selectable buffer time limiter as well as Ready Buffering and Replace battery contacts. For safety and maintenance an inhibit-input signal is included to enable phases without enforced buffering.
MTBF (Mean Time Between Failures)
639000h (at 40°C; 24Vdc input; MTBF SN 29500 IEC 61709)
1066000h (at 25°C; 24Vdc input; MTBF SN 29500 IEC 61709)
204000h (at 40°C; 24Vdc input; MTBF MIL HDBK 217F Ground Benign GB40)
275000h (at 25°C; 24Vdc input; MTBF MIL HDBK 217F Ground Benign GB25)
44000h (at 40°C; 24Vdc input; MTBF MIL HDBK 217F Ground Fixed GF40)
59000h (at 25°C; 24Vdc input; MTBF MIL HDBK 217F Ground Fixed GF25)
1066000h (at 25°C; 24Vdc input; MTBF SN 29500 IEC 61709)
204000h (at 40°C; 24Vdc input; MTBF MIL HDBK 217F Ground Benign GB40)
275000h (at 25°C; 24Vdc input; MTBF MIL HDBK 217F Ground Benign GB25)
44000h (at 40°C; 24Vdc input; MTBF MIL HDBK 217F Ground Fixed GF40)
59000h (at 25°C; 24Vdc input; MTBF MIL HDBK 217F Ground Fixed GF25)