Schneider Electric
XPSMCMMX0802G8 inputs 2 output pairs expansion module with spring term
8 inputs 2 output pairs expansion module with spring term
Safety mixed input/output (I/O) expansion module - SIL3 / SILCL3 - Schneider Electric / Modicon (Modicon MCM series) - 12I/Os [10DI (8 x digital inputs + 2 x digital inputs (Start/Restart interlock)) + 2DO (2 x digital outputs (24Vdc 100mA / 400mA; OSSD pairs))] - Supply voltage 19-30Vdc (24Vdc nom.) - DIN rail (35mm) mounting - with spring term. blck. - IP20 - Red color - Rated for +14...+131°F / -10...+55°C ambient
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
Brand
SKU
XPSMCMMX0802G
Online Price
$532.00
Please add this item to cart to request a quote or contact us at sales@lakelandengineering.com for product availability.
XPSMCMMX0802GSchneider Electric - Modicon MCM safety I/O modules
Description
Safety mixed input/output (I/O) expansion module - SIL3 / SILCL3 - Schneider Electric / Modicon (Modicon MCM series) - 12I/Os [10DI (8 x digital inputs + 2 x digital inputs (Start/Restart interlock)) + 2DO (2 x digital outputs (24Vdc 100mA / 400mA; OSSD pairs))] - Supply voltage 19-30Vdc (24Vdc nom.) - DIN rail (35mm) mounting - with spring term. blck. - IP20 - Red color - Rated for +14...+131°F / -10...+55°C ambient
Specifications
Primary brand
Schneider Electric
Secondary brand
Modicon
Main function
Safety I/O unit
Product series / family name
Modicon MCM
Sub-range name
Modicon MCM I/O modules
Functions
Safety mixed input/output (I/O) expansion module
Design
for Emergency Stop / guard monitoring / perimeter guarding / position monitoring / speed monitoring / enabling movement
Supply voltage (DC)
19-30Vdc (24Vdc nom.)
Display
1 green LED (power ON; PWR)
1 green LED (RUN (status); RUN)
1 red LED (internal error; E IN)
1 red LED (external error; E EX)
2 orange LEDs (node address; ADDR)
8 yellow LEDs (input status; IN)
2 yellow LEDs (restart signal; RST)
2 yellow LEDs (output status; STATUS)
2 green/red LEDs (output status; OUT)
1 green LED (RUN (status); RUN)
1 red LED (internal error; E IN)
1 red LED (external error; E EX)
2 orange LEDs (node address; ADDR)
8 yellow LEDs (input status; IN)
2 yellow LEDs (restart signal; RST)
2 yellow LEDs (output status; STATUS)
2 green/red LEDs (output status; OUT)
Color
Red color
Programming languages
SoSafe configurable software
Connection type
spring term. blck.
Mounting mode
DIN rail (35mm) mounting
Digital inputs
8 x digital inputs
2 x digital inputs (Start/Restart interlock)
2 x digital inputs (Start/Restart interlock)
Digital outputs
2 x digital outputs (24Vdc 100mA / 400mA; OSSD pairs)
Degree of protection
IP20
Ambient air temperature for operation
+14...+131°F / -10...+55 °C
Ambient air temperature for storage
-4...+185°F / -20...+85 °C
Humidity
10-95% (without condensation)
Technical compatibility with
Modicon MCM PLCs
Order code / Manufacturer SKU
XPSMCMMX0802G
Manufacturer product status
Commercialized
Compliant with standard(s)
cULus
IEC 62061
EN/IEC 61508
EN/ISO 13849-1
EN/IEC 61800-5-1
RCM
Certified by TUV Rheinland as suitable for use in an SIL3 level safety function
safety level -- Can reach category 4 EN/ISO13849-1 / PL = e EN/ISO13849-1 / SIL 3 EN/IEC61508 / SILCL 3 IEC62061
shock resistance -- 10gn 16ms (1000 shocks on each axis EN/IEC 61496-1)
DC > 99%
MTTFd < 100 years high
PFHd = 5.72E-9 1/h
IEC 62061
EN/IEC 61508
EN/ISO 13849-1
EN/IEC 61800-5-1
RCM
Certified by TUV Rheinland as suitable for use in an SIL3 level safety function
safety level -- Can reach category 4 EN/ISO13849-1 / PL = e EN/ISO13849-1 / SIL 3 EN/IEC61508 / SILCL 3 IEC62061
shock resistance -- 10gn 16ms (1000 shocks on each axis EN/IEC 61496-1)
DC > 99%
MTTFd < 100 years high
PFHd = 5.72E-9 1/h
Class
SIL3 / SILCL3
Benefits
The Safe expansion modules are designed for safety inputs and outputs
The safety inputs/outputs are configurable individually or in pairs -- with several possibilities
- Monitoring using line control via dedicated test outputs
- Configurable filters and delays for each single input
- Configurable output activation and deactivation delays
- Independent control of pairs of outputs
- Configurable diagnostic output signals
- Simple diagnostics via front led signalling / configuration software / communication expansion modules
The safety inputs/outputs are configurable individually or in pairs -- with several possibilities
- Monitoring using line control via dedicated test outputs
- Configurable filters and delays for each single input
- Configurable output activation and deactivation delays
- Independent control of pairs of outputs
- Configurable diagnostic output signals
- Simple diagnostics via front led signalling / configuration software / communication expansion modules
Related Documents
Name | Last Update | Language |
---|---|---|
Schneider Electric - Programmable Logic Controllers (PLCs) - Modicon MCM - Catalog.pdf | 08 Jan 2023 | English (US) |