Zelio control

RM17, RM22, RM35, REG range

Zelio Control Monitoring and Control Relays

Zelio Control relays monitor and detect abnormal operating conditions concerning phase,current,voltage,frequency,speed,or temperature. The relays inform users of abnormal conditions, and allow them to initiate the necessary corrective actions before serious and costly breakdown can occur.


Featurres

Zelio measurement and control relays can monitor power supplies (phases, voltage, current, frequency) to protect motors and other equipment or control physical values such as level, speed and temperature.

  • Phase control relay
  • Voltage & current control relays
  • Frequency control relay
  • Level control relay
  • Pump control relay
  • Speed control relay
  • Temperature control relay for lift application
  • Temperature control relays

Benefits
  • Compact modular sizes: 17.5mm/0.69 in., 22.5 mm/0.88 in., 35 mm/1.38in.
  • Adapted for industrial and building control panels
  • True RMS measurement that minimizes the possibility of unexpected trips from highly polluted networks
  • Diagnostic button to check the downstream circuit immediately and reduce commissioning and troubleshooting time *(1)
  • IP50 lead-sealable settings protection cover helps prevent dust and unintended human intervention
  • Status indication by LEDs, additional dial pointer LED for easy setup in dark conditions *(1), and power "On" status indication when relay is ready to perform
  • Optimization of power supplies >Worldwide certifications

  • *(1) Available in RM35JA32MR,RM35JA32MT, and all RM22 references

Applications
  • Hoisting: construction cranes, harbor cranes
  • Packaging: motor voltage, current overload
  • Lifts: construction lifts, passenger lifts, escalators
  • Textile: motor voltage, current overload
  • Water: liquid level on water tank at water and waste water recycling plant

Index


Zelio control

1. RM17 current protection relays

1.1 Single phase   (Back to top)
Application Single phase, 1 C/O SPDT, 5A
Function - Undervoltage with or without memory
- Overvoltage with or without memory
- Overvoltage and undervoltage in window mode - Integrated current transformer
- Overcurrent without memory
Measurement range
voltage
9-15Vdc 65-260Vac/Vdc 20-80Vac/Vdc 20-80Vac/Vdc 65-260Vac/Vdc 2-20A
Supply voltage Self-powered Self-powered Self-powered Self-powered Self-powered 24-240Vac/Vdc
Time delay 0.1-10s 0.1-10s 0.1-10s 0.1-10s 0.1-10s -
Product RM17UAS14
RM17UAS15
RM17UAS16
RM17UBE16
RM17UBE15
RM17JC00MW

1.2 3-phase   (Back to top)
Application 3-Phase, 1 C/O SPDT, 5A
Function - Phase sequence
- Phase loss
- Asymmetry
- Phase sequence
- Phase loss
- Asymmetry
- Overvoltage and Undervoltage
- Phase sequence
- Phase loss
- Phase sequence
- Phase loss
- Undervoltage
- Overvoltage and Undervoltage between phases
- Overvoltage and Undervoltage between phases and neutral
Measurement range
voltage
208-480Vac 208-480Vac 208-480Vac 208-440Vac 208-480Vac 208-480Vac 208-480Vac
Supply voltage Self-powered Self-powered Self-powered Self-powered Self-powered Self-powered Self-powered
Time delay 0.1-10s 0.1-10s - - - 0.1-10s 0.3-30s
Product RM17TA00
RM17TE00
RM17TG00
RM17TG20
RM17TT00
RM17TU00
RM17UB310

2. RM22 current protection relays

2.1 Single phase   (Back to top)
Application Single phase, 2 C/O DPDT, 8A
Functions - Overvoltage (without memory) - Overvoltage (with/without memory)
- Undervoltage (with/without memory)
- Overvoltage or undervoltage in window mode (with/without memory)
- Overvoltage and undervoltage
in window mode
- No integrated current transformer
- Overcurrent without memory
- No integrated current transformer
- Overcurrent with/without memory
- Undercurrent with/without memory
- Overcurrent and undercurrent
with/without memory and window mode
Measurement range
voltage
0.05-5Vac/Vdc 1-100Vac/Vdc 15-500Vac/Vdc 0.05-5Vac/Vdc 1-100Vac/Vdc 15-500Vac/Vdc 15-500Vac 80-300Vac/Vdc 4mA-1A 4mA-1A
Supply voltage 24-240Vac/Vdc 24-240Vac/Vdc 24-240Vac/Vdc 24-240Vac/Vdc 24-240Vac/Vdc 24-240Vac/Vdc 380-415Vac 110-240Vac/Vdc 24-240Vac/Vdc 24-240Vac/Vdc
Time delay - - - 0.1-30s
(OFF-delay)
0.1-30s
(OFF-delay)
0.1-30s
(OFF-delay)
0.1-30s
(OFF-delay)
0.1-30s - 0.1-30
Product RM22UA21MR
RM22UA22MR
RM22UA23MR
RM22UA31MR
RM22UA32MR
RM22UA33MR
RM22UA33MT
RM22UB34
RM22JA21MR
RM22JA31MR

2.2 3-phase   (Back to top)
Application 3-phase, 2 C/O DPDT, 8A
Functions - Phase sequence
- Phase loss
- Asymmetry
- Phase sequence
- Phase loss
- Phase sequence
- Phase loss
- Overvoltage and undervoltage
- Phase sequence
- Phase loss
- Undervoltage
Measurement range
voltage
200-240Vac 380-480Vac 183-528Vac 200-240Vac 380-480Vac 200-240Vac 380-480Vac
Supply voltage Self-powered Self-powered Self-powered Self-powered Self-powered Self-powered Self-powered
Time delay 0.1-30s 0.1-30s - 0.1-30s 0.1-30s - -
Product RM22TA31
RM22TA33
RM22TG20
RM22TR31
RM22TR33
RM22TU21
RM22TU23

2.3 Level control   (Back to top)
Application Level control, 8A
Functions - By resistive probes
- Level 1/ Level 2
- Fill operation
- Empty operation
- Standard sensitivity
- By resistive probes
- Level 1/ Level 2
- Fill operation
- Empty operation
- Standard sensitivity
- Low sensitivity
- High sensitivity
Measurement range
voltage
5k-100kΩ 5k-100kΩ 250k-1MΩ 250k-1MΩ
Supply voltage 24-240Vac/Vdc 380-415Vac 24-240Vac/Vdc 380-415Vac
Type of output 1 C/O SPDT 1 C/O SPDT 2 C/O DPDT 2 C/O DPDT
Time delay - - 0.1-30s 0.1-30s
Product RM22LG11MR
RM22LG11MT
RM22LA32MR
RM22LA32MT

3. RM35 current protection relays

3.1 Single phase   (Back to top)
Application Single phase, 2 C/O DPDT, 5A Single phase, 2 C/O DPDT, 8A
Functions - Overvoltage or Undervoltage with/without memory - No integrated current transformer
- Overcurrent with/without memory
- Undercurrent with/without memory
- No integrated current transformer
- Overcurrent with/without memory
- Undercurrent with/without memory
- Overcurrent and undercurrent
with/without memory and window mode
Measurement range
voltage
0.05-5Vac/Vdc 1-100Vac/Vdc 15-600Vac/Vdc 2-500mA 0.15-15A 150mA-15A 150mA-15A
Supply voltage 24-240Vac/Vdc 24-240Vac/Vdc 24-240Vac/Vdc 24-240Vac/Vdc 24-240Vac/Vdc 24-240Vac/Vdc 380-415Vdc
Time delay 0.3-30s 0.3-30s 0.3-30s Inhibition time delay upon startup 1-20s 0.3-30s 0.1-30s 0.1-30s
Product RM35UA11MW
RM35UA12MW
RM35UA13MW
RM35JA31MW
RM35JA32MW
RM35JA32MR
RM35JA32MT

3.2 3-phase   (Back to top)
Application 3-phase, 2 C/O DPDT, 5A 1 C/O + 1 C/O 1 per threshold
Functions - Phase sequence
- Phase loss
- Asymmetry
- Overvoltage and Undervoltage
- Phase sequence
- Phase loss
- Motor temperature
- Phase sequence
- Phase loss
- Motor temperature
- Selection (with or without memory)
"Test/Reset Button"
- Overvoltage and Undervoltage
between phases Overvoltage
and Undervoltage between phases and neutral
- Overvoltage and Undervoltage
between phases Overvoltage
and Undervoltage between phases and neutral
- Absence of neutral/ Phase
Measurement range voltage 220-480Vac 208-480Vac 208-480Vac 220-480Vac 120-277Vac
Supply voltage Self-powered 24-240Vac/Vdc 24-240Vac/Vdc Self-powered Self-powered
Time delay 0.1-10s - - 0.3-30s 0.3-30s
Product RM35TF30
RM35TM50MW
RM35TM250MW
RM35UB330
RM35UB3N30

3.3 Control   (Back to top)
Application Level control Pump control Frequency control Speed control Temperature control for elevator machine rooms and 3-phase supplies
Functions By resistive probes
- Level 1/ Level 2
- Fill operation
- Empty operation
- Standard sensitivity
- Low sensitivity
- High sensitivity
By discrete sensor
- Empty or fill
- Input for discrete sensor AON: Contact/ PNP/NPN
3phase and 1phase
- Overcurrent and undercurrent
- Phase sequence on 3phase supply
- Phase loss on 3phase supply
- Overfrequency and underfrequency
(with/without memory)
- Over or under operating rate / speed
(with/without memory)
- Elevator Machine room temperature
- Over temperature and under temperature
- Elevator Machine room temperature
- Over temperature and under temperature
- Phase loss and phase sequence
Measurement range voltage 0.25-1MOhm - 1-10A Mains supply: 40-60Hz (50Hz) / 50-70Hz (60Hz) Time controlled between pulses: 0.05-10min Overtemperature: 34-46℃
Undertemperature: -1-11℃
supply voltage 24-240Vac/Vdc 24-240Vac/Vdc 3-phase: 208-480Vac
single phase: 230Vac
120-277Vac 24-240Vac/Vdc 24-240Vac/Vdc 24-240Vac/Vdc 24-240Vac/Vdc
type of output 2 C/O DPDT 1 C/O SPDT 1 C/O SPDT 2 C/O DPDT 1 C/O SPDT 1 C/O SPDT 2 C/O DPDT 2 C/O DPDT
Rated current 5A 5A 5A 5A 5A 5A 5A 5A
Time delay 0.1-5s 0.1-5s 0.1-10s 0.1-10s 0.6-60s 0.1-10s 0.1-10s 0.1-10s
Product RM35LM33MW
RM35LV14MW
RM35BA10
RM35HZ21FM
RM35S0MW
RM35ATL0MW
RM35ATR5MW
RM35ATW5MW

4 Accessories   (Back to top)
Accessories
Product RM79696044
RM79696014
RM79696043
LA9RM201
RM79696006
Description probes probes Protected probe Liquid levelcontrol probe Electrode holders
For use with Drinks vending machines and where installation space is limited Boilers, pressure vessels and high temperature conditions probes probes Electrode

5. More information about relays operation   (Back to top)
Power supply OFF
Power supply ON
Output 11-14, 21-24 open
Output 11-14, 21-24 closed

Relays operation table

RM17TG⬤0 RM22TA RM22TU RM22TR RM22TG RM17TT00 RM17TU00 RM17TE00 RM35TF RM35UB330 RM35UB3N30 RM17UB310 RM35TM50MW RM35TM250MW RM17 UAS14/UAS15/UAS16 RM17 UBE15/UBE16 RM35 UA11MW/UA12MW/UA13MW RM22 UA2⬤MR/UA3⬤MR/UA33MT RM22 UA3⬤MR/UA33MT/UB34 RM17JC00MW RM22JA⬤1MR/RM35JA32M⬤ RM35 JA31MW/JA32MW RM22LA and RM22LG RM35LM33MW RM35LV14MW RM35BA10 RM35HZ21FM RM35S0MW RM35ATL0MW RM35ATR5MW RM35ATW5MW
Function Phase control Phase + Asymmetry Phase + Undervoltage Phase + Undervoltage/overvoltage Phase control Phase + Voltage regeneration Phase + Asymmetry Phase + Undervoltage Phase + Asymmetry + Undervoltage/overvoltage Phase + Overvoltage + Undervoltage in window mode Overvoltage/undervoltage control Overvoltage/undervoltage + absence of neutral control Overvoltage/undervoltage control 3-phase supply control Temperature control Motor temperature control via PTC probe with memory Use of "Test/Reset" button Undervoltage/Overvoltage without memory Undervoltage/Overvoltage with memory Overvoltage + undervoltage control in window mode Overvoltage without memory Undervoltage without memory Overvoltage/undervoltage with memory Overvoltage without memory Undervoltage without memory Overvoltage/undervoltage with memory Overvoltage + undervoltage control relay in window mode Overcurrent detection Overcurrent/Undercurrent without memory Overcurrent/Undercurrent with memory Overcurrent and undercurrent control in window mode Overcurrent without memory Undercurrent without memory Overcurrent/Undercurrent with memory Control of two levels, empty and fill function Control of one level, empty function Control of one level, fill function Control of two levels, empty and fill function Control of one level, empty function Control of one level, fill function Control of two levels Control of one level, empty function Control of one level, fill function Single control mode Double control mode 1-phase or 3-phase supply control mode Over-frequency and under-frequency without memory Underspeed control without memory Underspeed control with memory Underspeed control with inhibition by S2 Overspeed control without memory Overspeed control with memory Overspeed control with inhibition by S2 Temperature control by PT100 probe Temperature control by PT100 probe Temperature and phase control
Description Sequence of phases L1, L2, and L3
Phase loss
Sequence of phases L1, L2, and L3
Phase loss
Asymmetry Asy
Sequence of phases L1, L2, and L3
Phase loss
Undervoltage control Sequence of phases L1, L2, and L3
Phase loss
Overvoltage and undervoltage (Off-delay) Sequence of phases L1, L2, and L3
Phase loss
Sequence of phases L1, L2, and L3
Phase loss
Sequence of phases L1, L2, and L3
Phase loss
Asymmetry Asy
Sequence of phases L1, L2, and L3
Phase loss
Undervoltage control U Sequence of phases L1, L2, and L3
Phase loss
Asymmetry Asy
Control of overvoltage and undervoltage in window mode U> / U Sequence of phases L1, L2, and L3
Phase loss
Asymmetry Asy
Control of overvoltage and undervoltage in window mode Phase loss Overvoltage and undervoltage Phase loss Overvoltage and undervoltage Phase loss Overvoltage and undervoltage Sequence of phases L1, L2, and L3
Phase loss
Motor temperature control via PTC probe Memory No Memory Memory Undervoltage control Overvoltage control U>, No Memory Undervoltage control U Overvoltage control U>, Memory undervoltage control Overvoltage control > U, without memory Undervoltage control Undervoltage control Undervoltage control Overvoltage control > U, without memory Undervoltage control Overvoltage control > U, with memory Undervoltage control Overvoltage and undervoltage control in window mode Overcurrent detection > I Overcurrent detection >I , without memory Undercurrent detection Overcurrent >I, with memory Undercurrent Overcurrent and undercurrent control in window mode Overcurrent detection >I, without memory Undercurrent detection Overcurrent detection >I, with memory Undercurrent detection Fill/Empty function (2 levels) Empty function T on Empty function T off Fill function T on Fill function T off Fill/Empty function Empty function T on Empty function T off Fill function T on Fill function T off Fill/Empty function Empty function T on Empty function T off Empty function T on Empty function T off Single control mode (3-ph/1-ph) Double control mode (3-ph/1-ph) Overcurrent detection > I Undercurrent detection Over-frequency and under-frequency control, without memory Over-frequency and under-frequency with memory Underspeed control, without memory Underspeed control, with memory With inhibition by S2 Inhib./S2 Overspeed control, without memory Overspeed control, with memory With inhibition by S2. Inhib./S2 Temperature control by PT100 probe Temperature control by PT100 probe Temperature control by PT100 probe
Sequence of phases L1, L2, and L3
Phase loss
Operating principle
Remark Tr: response time on detection of a fault Tt: time delay after crossing of the threshold (adjustable on the front panel) Tt: time delay after crossing of the threshold Tt: time delay after crossing of the threshold (adjustable on the front panel) Tr: response time on appearance of a fault - Tt: time delay after crossing of the threshold (adjustable on front panel) Tt: time delay after crossing of the threshold (adjustable on front panel) Tt: time delay after crossing of the threshold (adjustable on front panel) Tt: time delay after crossing of the threshold (adjustable on front panel) Tt 1: overvoltage threshold delay (adjustable on front panel)
Tt 2: undervoltage threshold delay (adjustable on front panel)
Tt 1: overvoltage threshold delay (adjustable on front panel)
Tt 2: undervoltage threshold delay (adjustable on front panel)
Tt: overvoltage and undervoltage threshold delay (adjustable on front panel) - - - - - - - Tt: time delay after crossing of the threshold Tt: time delay after crossing of the threshold Tt: time delay after crossing of the threshold (adjustable on front panel) - Tt: time delay after crossing of the threshold (adjustable on front panel) - - Tt: time delay after crossing of the threshold Tt: time delay after crossing of the threshold - Tt: time delay after crossing of the threshold Tt: time delay after crossing of the threshold Tt: time delay after crossing of the threshold - - Ti: starting inhibition time (adjustable on front panel) Tt: time delay after crossing of the threshold (adjustable on front panel) - - - Tt: time delay after crossing of the threshold When two levels are being controlled, the anti-wave time delay function is not active. - - - - When two levels are being controlled, the anti-wave time delay function is not active. - - - - Ti: time delay to inhibit fault monitoring on pump starting (overcurrent and undercurrent, setting on front panel)
Tt: time delay on occurrence of a fault (overcurrent or undercurrent, setting on front panel)
I. Def.: presence of a current fault (overcurrent or undercurrent)
Ti: time delay to inhibit fault monitoring on pump starting (overcurrent and undercurrent, setting on front panel)
Tt: time delay on occurrence of a fault (overcurrent or undercurrent, setting on front panel)
I. Def.: presence of a current fault (overcurrent or undercurrent)
Ti: time delay to inhibit fault monitoring on pump starting (overcurrent and undercurrent, setting on front panel)
Tt: time delay on occurrence of a fault (overcurrent or undercurrent, setting on front panel)
Tt: time delay after crossing of the threshold (adjustable on front panel) - - - - - - - - -