Masterpact NW ACBs
Air Circuit Breakers from 800A to 6300A
Masterpact NW Air Circuit Breakers
The market leading Air Circuit Breaker, for high performance applications:- Rated performance: 800-6300A, Icu=ics=42-150kA at 220/415Vac
- Voltage rating: up to 1000 V
- Only 2 frame sizes and 2 pole pitches (800-4000A and 4000-6300 A), to simplify mechanical assembly in switchboard
- 3- and 4-pole versions
- 5 types of Micrologic control units with added measurement, energy-management and network-analysis functions
- Earth leakage protection built into the control unit
- Wide range of common auxiliaries and accessories interchangeable on site
- Compliance with international standards IEC 60947-1 and 2, IEC 68230 for type 2 tropicalization, UL489 and ANSI/UL1066, as well as CCC and GOST certifications
- Compliance with specifications of marine classification bodies: Bureau Veritas, Lloyd’s Register of Shipping, Det Norske Veritas, etc.
- The worldwide benchmark for high-current circuit-breakers, known everywhere
- The Masterpact NW circuit-breaker range features optimised dimensions: not only is it more compact, but even better two sizes are sufficient to cover requirements from 4000 to 6300 A.
- At a time when installations are becoming increasingly complex, Masterpact NW enables standardisation of electrical switchboards by providing unrivalled simplicity in terms of both choice and installation.
- Protection, measurement and communication of LV electrical networks
- Generator protection
- Motor protection
- DC networks
- Protection of installations in highly corrosive industrial environments
- Mines (special 1000V version of NW)
- Navy
- Earthing switch
- High short-circuit current limiting (ultra-rapid Masterpact UR)
Index
1. Select your Micrologic electronic trip unit
2. 3-pole ACBs
2.1. Fixed type ACBs
3P / Icu=Ics=65kA
2.2. Fixed type ACBs
3P / Icu=Ics=100kA
2.3. Fixed type ACBs
3P / Icu=Ics=150kA
2.4. Drawout type ACBs
3P / Icu=Ics=65kA
2.5. Drawout type ACBs
3P / Icu=Ics=100kA
2.6. Drawout type ACBs
3P / Icu=Ics=150kA
3P / Icu=Ics=65kA
2.2. Fixed type ACBs
3P / Icu=Ics=100kA
2.3. Fixed type ACBs
3P / Icu=Ics=150kA
2.4. Drawout type ACBs
3P / Icu=Ics=65kA
2.5. Drawout type ACBs
3P / Icu=Ics=100kA
2.6. Drawout type ACBs
3P / Icu=Ics=150kA
3. 4-pole ACBs
3.1. Fixed type ACBs
4P / Icu=Ics=65kA
3.2. Fixed type ACBs
4P / Icu=Ics=100kA
3.3. Fixed type ACBs
4P / Icu=Ics=150kA
3.4. Drawout type ACBs
4P / Icu=Ics=65kA
3.5. Drawout type ACBs
4P / Icu=Ics=100kA
3.6. Drawout type ACBs
4P / Icu=Ics=150kA
4P / Icu=Ics=65kA
3.2. Fixed type ACBs
4P / Icu=Ics=100kA
3.3. Fixed type ACBs
4P / Icu=Ics=150kA
3.4. Drawout type ACBs
4P / Icu=Ics=65kA
3.5. Drawout type ACBs
4P / Icu=Ics=100kA
3.6. Drawout type ACBs
4P / Icu=Ics=150kA
4. Common Masterpact ACB accessories and auxiliaries
4.1. Auxiliary indication contacts4.2. Remote operation and charging motors
4.3. Accessories & connections
4.4. External sensors / current transformers (CTs)
4.5. Locking / interlocking
4.6. Other Masterpact accessories
5. Additional documentation
1. Selection the Micrologic trip unit for your ACB
(back to index)Type of trip unit | ||||||
---|---|---|---|---|---|---|
ANSI code | (replacing 2.0A) |
(replacing 5.0A) |
||||
49 | ⬤ | ⬤ | ⬤ | ⬤ | ||
51 | ⬤ | ⬤ | ⬤ | |||
50 | ⬤ | ⬤ | ⬤ | ⬤ | ||
51G | ⬤ | ⬤ | ||||
51N | ⬤ | |||||
protections |
46 (Current/Voltage unbalance) 47 (Phase sequence) 27 (Undervoltage) 59 (Overvoltage) 32P (Reverse Power) |
⬤ | ||||
Current | ⬤ | ⬤ | ⬤ | ⬤ | ||
⬤ | ||||||
⬤ | ||||||
⬤ | ⬤ | ⬤ | ⬤ | |||
⬤ | ⬤ | ⬤ | ⬤ | |||
|
⬤ | |||||
⬤ | ||||||
⬤ |
2. 3-pole (3P) Masterpact ACBs
2.1. Fixed type ACBs - Ics=Icu=65kA - 3 poles (3P)
(back to index)2.2. Fixed type ACBs - Ics=Icu=100kA - 3 poles (3P)
(back to index)2.3. Fixed type ACBs - Ics=Icu=150kA - 3 poles (3P)
(back to index)2.4. Drawout / Withdrawable type ACBs - Ics=Icu=65kA - 3 poles (3P)
(back to index)2.5. Drawout / Withdrawable type ACBs - Ics=Icu=100kA - 3 poles (3P)
(back to index)2.6. Drawout / Withdrawable type ACBs - Ics=Icu=150kA - 3 poles (3P)
(back to index)3. 4-pole (4P) Masterpact ACBs
3.1. Fixed type ACBs - Ics=Icu=65kA - 4 poles (4P)
(back to index)3.2. Fixed type ACBs - Ics=Icu=100kA - 4 poles (4P)
(back to index)3.3. Fixed type ACBs - Ics=Icu=150kA - 4 poles (4P)
(back to index)3.4. Drawout / Withdrawable type ACBs - Ics=Icu=65kA - 4 poles (4P)
(back to index)3.5. Drawout / Withdrawable type ACBs - Ics=Icu=100kA - 4 poles (4P)
(back to index)3.6. Drawout / Withdrawable type ACBs - Ics=Icu=150kA - 4 poles (4P)
(back to index)4. Common Masterpact ACB accessories and auxiliaries
4.1. Auxiliary indication contacts
(back to index)ON/OFF (OF) auxiliary indication contacts | Combined CB closed + connected auxiliary indication contacts | Fault trip (SDE) indication contacts | Programmable contacts (programmed via Micrologic) |
(PF) contact (5A) |
Carriage switches (connected / disconnected / test position) (1 C/O / SPDT contact) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 additional block of |
1 additional fault |
programmed via Micrologic - 5A rating | 1 C/O / SPDT contact | 1 connected position contact (3 max.) | 1 test position contact (3 max.) | 1 disconnected position contact (3 max.) |
carriage switches |
|||||||||
Fixed type ACBs | 48198 |
- | 48200 |
Low-level 48201 |
47403 |
47404 |
47342 |
47343 |
- | - | - | - | - | - | - | |
Drawout / witdrawable ACBs | 48468 |
48477 |
Low-level 48478 |
48475 |
Low-level 48476 |
48382 |
48383 |
48469 |
Low-level 48470 |
33751 |
Low-level 33754 |
33752 |
Low-level 33755 |
33753 |
Low-level 33756 |
48560 |
4.2. Remote operation (electrical coils / releases) and charging motors
4.2.1. Remote operation (electrical coils / releases) for fixed type ACBs
(back to index)AC | DC | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
24Vac | 48Vac | 100-130Vac | 200-240Vac | 250-277Vac | 380-415Vac | 440-480Vac | 12Vdc | 24/30Vdc | 48/60Vdc | 100-130Vdc | 200-250Vdc | ||
|
- | 48207 | 48211 | 48212 | 48213 | 48214 | 48215 | - | 48206 | 48207 | 48208 | 48209 | |
Closing coil |
Standard (XF) |
47350 | 47351 | 47352 | 47353 | 47354 | 47355 | 47349 | 47350 | 47351 | 47352 | 47353 | |
Communicating (XF com) | 47311 | 47312 | 47313 | 47314 | 47315 | 47316 | 47310 | 47311 | 47312 | 47313 | 47314 | ||
Shunt trip coil / opening release |
Standard (MX) |
47360 | 47361 | 47362 | 47363 | 47364 | 47365 | 47359 | 47360 | 47361 | 47362 | 47363 | |
Communicating (MX com) |
47321 | 47322 | 47323 | 47324 | 47325 | 47326 | 47320 | 47321 | 47322 | 47323 | 47324 | ||
coil (MX) |
47370 | 47371 | 47372 | 47373 | 47374 | 47375 | 47369 | 47370 | 47371 | 47372 | 47373 | ||
Undervoltage trip coil | (MN) | 47380 | 47381 | 47382 | 47383 | - | 47385 | - | 47380 | 47381 | 47382 | 47383 | |
Remote reset | - | - | 48202 | - | 48203 | - | - | - | - | - | - | - |
4.2.2. Remote operation (electrical coils / releases) for drawout / withdrawable type ACBs
(back to index)AC | DC | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
24Vac | 48Vac | 100-130Vac | 200-240Vac | 250-277Vac | 380-415Vac | 440-480Vac | 12Vdc | 24/30Vdc | 48/60Vdc | 100-130Vdc | 200-250Vdc | ||
|
- | 48522 | 48526 | 48527 | 48528 | 48529 | 48530 | - | 48521 | 48522 | 48523 | 48524 | |
Closing coil |
Standard (XF) |
48481 | 48482 | 48483 | 48484 | 48485 | 48486 | 48480 | 48481 | 48482 | 48483 | 48484 | |
Communicating (XF com) | 48449 | 48450 | 48451 | 48452 | 48485 | 48486 | 48448 | 48449 | 48450 | 48451 | 48452 | ||
Shunt trip coil / opening release |
Standard (MX) |
48491 | 48492 | 48493 | 48494 | 48495 | 48496 | 48490 | 48491 | 48492 | 48493 | 48494 | |
Communicating (MX com) |
48458 | 48459 | 48460 | 48461 | 48462 | 48463 | 48457 | 48458 | 48459 | 48460 | 48461 | ||
coil (MX) |
48511 | 48512 | 48513 | 48514 | 48515 | 48516 | 48510 | 48511 | 48512 | 48513 | 48514 | ||
Undervoltage trip coil | (MN) | 48501 | 48502 | 48503 | 48504 | - | 48506 | - | 48501 | 48502 | 48503 | 48504 | |
Remote reset | - | - | 48472 | - | 48473 | - | - | - | - | - | - | - |
4.3. Accessories & connections
4.3.1. Accessories & connections for fixed ACBs
(back to index)Horizontal | Vertical | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
800-2000A 800-1600A (type L1) |
2500-3200A 2000A (type H3 & L1) |
4000A | 4000b-5000A | 800-2000A 800-1600A (type L1) |
2500-3200A 2000A (type H3 & L1) |
4000A | 4000b-5000A | 6300A | ||||||
3-poles | top | 48143 | 48144 | 48145 | 48146 | 48133 | 48134 | 48135 | 48136 | 48137 | interphase barriers 48599 |
interphase barriers 47829 |
||
bottom | 48148 | 48149 | 48150 | 48151 | 48138 | 48139 | 48140 | 48141 | 48142 | |||||
4-poles | top | 48168 | 48169 | 48170 | 48171 | 48158 | 48159 | 48160 | 48161 | 48162 | ||||
bottom | 48173 | 48174 | 48175 | 48176 | 48163 | 48164 | 48165 | 48166 | 48167 |
4.3.2. Accessories & connections for drawout / withdrawable ACBs
(back to index)Horizontal | Vertical | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
800-2000A 800-1600A (type L1) |
2500-3200A 2000A (type H3 & L1) |
4000A | 4000b-5000A | 800-2000A 800-1600A (type L1) |
2500-3200A 2000A (type H3 & L1) |
4000A | 4000b-5000A | 6300A | |||||
3-poles | top | 48143 | 48144 | 48145 | 48146 | 48133 | 48134 | 48135 | 48136 | 48137 | Interphase barriers 48599 |
||
bottom | 48148 | 48149 | 48150 | 48151 | 48138 | 48139 | 48140 | 48141 | 48142 | ||||
4-poles | top | 48168 | 48169 | 48170 | 48171 | 48158 | 48159 | 48160 | 48161 | 48162 | |||
bottom | 48173 | 48174 | 48175 | 48176 | 48163 | 48164 | 48165 | 48166 | 48167 |
4.3.3. Drawout / withdrawable ACBs chassis accessories
(back to index)Chassis accessories | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Arc chute cover | Auxiliary terminal shield (CB) | Safety shutters (standard with every ACB |
(for replacement) |
Front face shutter position indication and locking | ||||||||
Standard with every ACB | 800-4000A | 4000b-6300A | 800-4000A | 4000b-6300A | 800-4000A | 800-4000A | 4000b-6300A | |||||
3P 48595 |
4P 48596 |
3P 48597 |
4P 48598 |
3P 48721 |
4P 48722 |
3P 48723 |
4P 48724 |
2 parts 48591 |
3P/4P 48592 |
3P 48593 |
4P 48594 |
4.4. External sensors / current transformers (CTs)
(back to index)Voltage measurement input (for breakers supplied via bottom terminals) | External sensor for earth-fault protection (TCE) | Source ground return (SGR) earth fault protection | Rectangular sensor for earth-leakage protection | ||||
---|---|---|---|---|---|---|---|
33579 |
48891 |
400-2000A 34035 |
1000-4000A 34036 |
4000-6300A 48182 |
47506 |
48533 |
33574 |
For all Micrologic E versions | For Micrologic 6.0E/6.0P only | For Micrologic 7.0 only |
4.5. Locking / interlocking
4.5.1. Locking
(back to index)VCPO |
Profalux keylocks | Ronis keylocks | Optional disconnected / test / connected position locking | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
kit |
kit |
kit |
combination |
215470 combination |
215471 combination |
kit |
kit |
kit |
EL24135 combination |
EL24153 combination |
EL24315 combination |
Ronis |
Castell |
Kirk |
||||
Fixed type ACBs |
installed by default on every device |
48536 |
48568 |
48569 |
48570 |
33173 |
33174 |
33175 |
48572 |
48573 |
48574 |
33189 |
33190 |
33191 |
33192 |
48564 |
48565 |
48566 |
Drawout / withdrawable type ACBs | 48539 |
48545 |
48546 |
48547 |
48549 |
48550 |
48551 |
48541 |
48542 |
48543 |
4.5.2. Interlocking (with door / source change-over
(back to index)
|
Door interlock (1 part) | Racking interlock | OFF pushbutton |
before breaker removal |
protection |
Source change-over interlocks | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Fixed type ACBs |
48614 |
- | - | - | - | - | - | Interlocking by rods 48612 |
Set of 2 cables 33209 |
fixture 47926 |
"1-out-of-3") 48610 |
("2-out-of-3") 48609 |
+1 replacement source 48608 |
Drawout / withdrawable ACBs |
Right-hand 48579 |
Left-hand 48580 |
1 part 48582 |
1 part 48585 |
1 part 48554 |
protection VDC 33767 |
4.6. Other Masterpact accessories
(back to index)Fixed type ACBs | Escutcheon 48601 |
- | Escutcheon blanking plate 48605 |
Drawout / withdrawable ACBs | Escutcheon 48603 |
Transparent cover IP54 48604 |