Acti9
Modular protection devices
Main index
1. iC60
Miniature Circuit Breakers (MCBs)
2. iID
Residual Current Circuit Breakers (RCCBs)
3. iDPN Vigi
RCBO / ELCB (Residual Current Circuit Breaker with Overload protection / Earth Leakage Circuit Breaker)
4. Vigi iC60
Residual Current Device (RCD) add-ons to Miniature Circuit Breakers)
5. Accessories / auxiliaries
auxiliary contacts SD/OF, locking accessories, terminal covers, etc.
6. Control add-ons
Automatic reclosers, Remote control, closing / tripping coils
Miniature Circuit Breakers (MCBs)
2. iID
Residual Current Circuit Breakers (RCCBs)
3. iDPN Vigi
RCBO / ELCB (Residual Current Circuit Breaker with Overload protection / Earth Leakage Circuit Breaker)
4. Vigi iC60
Residual Current Device (RCD) add-ons to Miniature Circuit Breakers)
5. Accessories / auxiliaries
auxiliary contacts SD/OF, locking accessories, terminal covers, etc.
6. Control add-ons
Automatic reclosers, Remote control, closing / tripping coils
1. Acti9 iC60 miniature circuit breakers
(back to index)With exclusive features, the Acti 9 iC60 DIN rail miniature circuit breakers have been specifically designed to provide absolute protection as well as first-rate continuity of service.
- VisiSafe: provides protection during maintenance work on circuits.
- Class-2 insulation: ensures continuous protection for both operators and unqualified persons.
- VisiTrip: works to quickly detect faulty miniature circuit breaker outgoers and reduce
- intervention time.
- Add-on fully immune earth leakage protection devices: improved continuity of service, especially in polluted environments and networks.
- Nominal current: 1 to 63 A.
- Large choice of breaking capacities (up to 100 kA) and tripping curves: B, C, D, K, Z, MA
- Fully compliant with standards IEC/EN 60898 and IEC/EN 60947-2.
- Full compatibility with the Acti 9 range of residual current devices (RCDs) and compact NSX molded case circuit breakers (MCCBs).
- Suitable for isolation in compliance with industrial standard IEC 60947.
- Operating voltage: up to 440 V AC, insulation voltage: 500 V.
- Provides installers with optional add-on earth leakage modules: iC60 Vigi.
- Offers a range of optional auxiliaries: indication of state and trip device, shunt trip, undervoltage trip, overvoltage trip.
- Complete with VisiSafe and VisiTrip, our miniature circuit breakers expertly combine reliability, protection and ease of use.
- Set a new benchmark in final distribution circuit breakers.
- Absolute security when it comes to circuit protection thanks to VisiSafe.
- Provide greater continuity of service thanks to VisiTrip.
- Come with easily identifiable part numbers, making the circuit breakers simple to use.
- Easy installation with quick, ergonomic and safe IP20B terminal shutters.
- Highly durable with robust connections that provide twice the standard tightening torque.
- Environmentally friendly with 100% recyclable and recoverable materials.
- Providing essential protection in industrial and commercial buildings, our miniature circuit breakers work especially well in polluted environments and networks.
- For the enhanced protection of electrical circuits in all types of industrial and commercial buildings.
- Suitable for all settings, particularly polluted environments and networks.
- Motor circuit protection.
- DC current circuit protection.
Acti9 iC60 miniature circuit breakers - range overview
(back to index)1.1. iC60N (Icu = 10kA at 415Vac as per IEC60947-2 / Icn = 6000A / 6kA as per IEC60898)
1.2. iC60H (Icu = 15kA at 415Vac as per IEC60947-2 / Icn = 10000A / 10kA as per IEC60898)
1.3. iC60L (Icu = 15-25kA at 415Vac as per IEC60947-2 / Icn = 15000A / 15kA as per IEC60898)
1.1. iC60N (Icu = 10kA at 415Vac as per IEC60947-2 / Icn = 6000A / 6kA as per IEC60898)
1.1.1. iC60N B-curve - Product selection table
(back to index)1.1.2 iC60N C-curve - Product selection table
(back to index)1.1.3. iC60N D-curve - Product selection table
(back to index)1.2. iC60H (Icu = 15kA at 415Vac as per IEC60947-2 / Icn = 10000A / 10kA as per IEC60898)
1.2.1. iC60H B-curve - Product selection table
(back to index)1.2.2 iC60H C-curve - Product selection table
(back to index)1.2.3. iC60H D-curve - Product selection table
(back to index)1.2.4. iC60H K-curve, Z-curve - Product selection table
(back to index)1.3. iC60L (Icu = 15-25kA at 415Vac as per IEC60947-2 / Icn = 15000A / 15kA as per IEC60898)
1.3.1. iC60L B-curve - Product selection table
(back to index)1.3.2. iC60L C-curve - Product selection table
(back to index)1.3.3. iC60L K-curve - Product selection table
(back to index)1.3.4. iC60L Z-curve - Product selection table
(back to index)1.3.5. iC60L MA-curve - Product selection table
(back to index)2. iID RCCBs (Residual Current Circuit Breakers)
(back to index)Features
- Achieve full coordination with Acti 9 and Multi 9 MCBs with DIN rail RCCB you can rely on. Providing better continuity of service as well as offering a complete environmentally friendly option, the DIN rail RCCB will also give you additional protection against any direct contact.
- Complete with VISI-SAFE, which helps to ensure the ultimate in safety for both operation and maintenance work.
- Class-2 insulation: ensures continuous safety for both operators and unqualified personnel.
- Complete with VisiTrip: detects faulty outgoers quickly and reduces intervention time.
- Fully immune earth leakage protection: provides better continuity of service, especially with the new SI type (Super immune) which has been designed with polluted environments and networks in mind.
- The optional electrical auxiliaries and mounting accessories are consistent with those offered on Acti 9 iC60 miniature circuit breakers (MCBs).
- Nominal current: 1 to 100 A.
- SI (Super immune), AC, A.
- 30 mA sensitivity: provides additional protection against direct contact (in accordance with IEC 60364).
- 100 mA, 300 mA, 500 mA sensitivities: provide additional protection against fire and indirect contact (in accordance with IEC 60364).
- Selective version: ensures correct discrimination between different residual current circuit breakers as well as the tripping of the device closest to the fault.
- Full coordination with Acti 9 and Multi 9 MCBs.
- Fully compliant with standard IEC EN 61008-1.
- Fully certified by national official authorities.
- Ideally suited to isolation in full accordance with industrial standard IEC/EN 60947-2.
- Operating voltage: up to 400 V AC.
- Insulation voltage: 500 V.
- Optional auxiliaries available: indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping.
- Complete with VisiTrip and Visi-SAFE, the DIN rail RCCB provide greater continuity of service as well as enhanced safety to both industrial and commercial buildings.
- Greater continuity of service with VisiTrip.
- Greater electrical immunity with SI type (Super immune).
- Easy-to-understand part numbers make choosing options simple and straightforward.
- Easy to install with quick, ergonomic and safe IP20B terminal shutters.
- Fully robust connections which provide twice the standard tightening torque.
- Environmentally friendly: made from 100% recyclable and recoverable materials.
- Ensure the industrial or commercial building you are working on is fully protected with expertly designed DIN rail RCCB.
- Fully compliant with all industrial standards and certified by the national official authorities, the DIN rail RCCB will provide protection against everything from electrocution to earth leakage.
- Designed with industrial and commercial buildings in mind.
- Prevent electrocution (in full accordance with installation standard IEC 60364 and national standards).
- Reduce fire hazards by cutting down current leakage into building electrical installations.
Acti9 iID RCCBs - range overview
(back to index)
2.1. Type AC
protection of:
general purpose power sockets
incandescent lighting
general appliances with rectifier/inverter
2.2. Type A
protection of:
appliances with rectifier
single-phase variable speed drives / inverters
2.3. Type SI
protection of appliances generating high frequency interferences (current peaks, harmonics)
installation in proximity of high powered switching devices
installation in circuits powered by UPS
installation in buildings protected by surge protection devices
protection of:
2.2. Type A
protection of:
2.3. Type SI
2.1. Acti9 iID RCCBs - Type AC - Product selection table
(back to index)2.2. Acti9 iID RCCBs - Type A - Product selection table
(back to index)2.3. Acti9 iID RCCBs - Type SI - Product selection table
(back to index)Characteristics | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
25A | 40A | 63A | 80A | 100A | ||||||||||||
Standard | Standard | Selective | Standard | Selective | Standard | Selective | Standard | Selective | ||||||||
Poles | IΔn = | 10mA | 30mA | 30mA | 300mA | 500mA | 30mA | 300mA | 300mA | 500mA | 30mA | 300mA | 500mA | 30mA | 300mA | 300mA |
2P | 2P 25A 10mA SI-type |
2P 25A 30mA SI-type |
2P 40A 30mA SI-type |
2P 40A 300mA SI-type selective |
- | 2P 63A 30mA SI-type |
- | 2P 63A 300mA SI-type selective |
- | - | - | - | - | - | 2P 100A 300mA SI-type selective |
|
4P | - | 4P 25A 30mA SI-type |
4P 40A 30mA SI-type |
4P 40A 300mA SI-type selective |
4P 40A 500mA SI-type selective |
4P 63A 30mA SI-type |
4P 63A 300mA SI-type |
4P 63A 300mA SI-type selective |
4P 63A 500mA SI-type selective |
4P 80A 30mA SI-type |
4P 80A 300mA SI-type selective |
4P 80A 500mA SI-type selective |
4P 100A 30mA SI-type |
4P 100A 300mA SI-type |
4P 100A 300mA SI-type selective |
3. iDPN Vigi RCBO / ELCB (Residual Current Circuit Breaker with Overload protection / Earth Leakage Circuit Breaker)
(back to index)Features
- Thanks to its exclusive features, the Acti 9 range for low voltage DIN rail system provides absolute safety and better continuity of service.
- VisiSafe: for safe operation and maintenance work on circuits.Class-2 insulation: continuous safety for operators and non-qualified personnel.
- VISI-TRIP: detects faulty Miniature Circuit-Breaker outgoers quickly and reduces intervention time.
- Fully immune add-on Residual Current Devices: better continuity of service, in particular for polluted networks and environments.
- The Reflex iC60 all-in-one concept, a one-piece combined unit integrating a circuit-breaker + contactor + impulse relay.
- Total coordination guaranteed by Schneider Electric.
- Optimised design time, in particular for lighting solutions in buildings.
- 50% fewer connections with the Reflex iC60 all-in-one concept
- Flexible, upgradeable solutions and simple operations
- Easier status diagnosis via product front face indications
- Multiclip distribution systems suitable for upgrading electrical facilities, add-ons, adaptation, phase balancing, etc.
- Easy to adapt to constraints and last-minute changes in the tertiary and industrial fields
- Operating and control mode selection
- Building management system interfacing
- Limitation of intervention costs on remote structures thanks to the new automatic remote control auxiliary.
- The efficiency you deserve
- Acti 9 is a DIN rail switchgear system that combines efficiency with safety to ensure maximum safety for you, your customers and their installations.
- Acti 9 is packed full of innovations.
- Acti 9 enjoys the benefits of Schneider Electric's more than 40 years of experience.
- Acti 9 covers all applications, especially polluted environments and networks with absolute safety and improved continuity of service. Example: VisiTrip detects Faulty outgoers.
- Acti 9 is easy to choose, thanks to its meaningful part numbers. Example: A9XXX225 = 2P, 25A.
- Acti 9 is easy to install and environmentally friendly. Example: Its components are 100% recyclable and recoverable.
- Low-voltage final distribution
- Protection by Miniature Circuit-Breaker (MCB) in all industrial and commercial buildings.
- Protection of motor circuits.Protection of DC circuits.
- Protection of people and property by super-immune earth leakage Residual Current Devices (RCDs).
- Protection by surge arresters against overvoltages of atmospheric origin.
- Control of power and control circuits by contactors and impulse relays.
- Remote control of circuits by remote controls associated with Miniature Circuit-Breaker.Remote control and protection of circuits by integrated control circuit-breaker.
- Programming, regulation, signalling, etc.
Acti9 iDPN Vigi RCBO / ELCB - range overview
(back to index)3.1 - iDPN N Vigi - Icn = 6000A / 6kA - Product selection table
Type AC
protection of:
general purpose power sockets
incandescent lighting
general appliances with rectifier/inverter
Type A
protection of:
appliances with rectifier
single-phase variable speed drives / inverters
Type SI
protection of appliances generating high frequency interferences (current peaks, harmonics)
installation in proximity of high powered switching devices
installation in circuits powered by UPS
installation in buildings protected by surge protection devices
protection of:
protection of:
3.2 - iDPN H Vigi - Icn = 10000A / 10kA - Product selection table
Type A
protection of:
appliances with rectifier
single-phase variable speed drives / inverters
Type SI
protection of appliances generating high frequency interferences (current peaks, harmonics)
installation in proximity of high powered switching devices
installation in circuits powered by UPS
installation in buildings protected by surge protection devices
protection of:
3.1.1 - iDPN N Vigi - Icn = 6000A / 6kA - Type AC - Product selection table
(back to index)3.1.2 - iDPN N Vigi - Icn = 6000A / 6kA - Type A - Product selection table
(back to index)3.1.3 - iDPN N Vigi - Icn = 6000A / 6kA - Type SI - Product selection table
(back to index)3.2.1 - iDPN H Vigi - Icn = 10000A / 10kA - Type A - Product selection table
(back to index)3.2.2 - iDPN H Vigi - Icn = 10000A / 10kA - Type SI - Product selection table
(back to index)4. Vigi iC60 RCD (Residual Current Devices, add-on to Miniature Circuit Breakers)
(back to index)Features YYYY
- Class-2 insulation: ensures continuous protection for both operators and unqualified personnel.
- VISI-TRIP: quickly detects faulty outgoers and reduces intervention time.
- Fully immune earth leakage protection: provides enhanced continuity of service, especially with the new “SI” (Super Immune) type for application in polluted environments and networks.
- Easily connect to Acti 9 iC60 Miniature Circuit-Breakers (MCBs) either electronically or manually.
- Nominal current ranges from 25 to 63 A.
- Comes in “SI” (Super Immune), AC, and A types.
- 30 mA sensitivity for additional protection against direct contact (in compliance with IEC 60364).
- 100 mA, 300 mA, 500 mA and 1000 mA sensitivities for additional protection against fire and indirect contact (in compliance with IEC 60364).
- “SI” (Super Immune) type: protects sensitive circuits (IT equipment) and those prone to disturbances (electronic ballasts for light fixtures, power electronics).
- Selective type: guarantees selectivity to correctly distinguish between different residual current devices (RCDs) and trip the device closest to the fault.
- Complies with IEC EN 61009-1 standard, certified by national authorities.
- Acti 9 iC60 DIN rail miniature circuit breakers (MCBs) retain the same characteristics when combined with an Acti 9 Vigi iC60 DIN rail add-on residual current device (RCD).
- From adding protection to polluted environments and networks to ensuring a greater continuity of service, the Acti 9 Vigi iC60 also boasts impressive environmental credentials.
- 100% earth leakage protection in final distribution.
- Greater continuity of service with VisiTrip.
- Greater electrical immunity with “SI” (Super Immune) type.
- Meaningful part numbers make selection easy.
- Easy to install with robust terminal connections.
- Environmentally friendly, made with 100% recyclable and recoverable materials.
Ideal for installation in all industrial and commercial buildings, residual current add-on devices provide protection against:
- Electrocution (in compliance with IEC 60364 installation standards and national standards).
- Fire hazards caused by leakage currents flowing into building materials.
Vigi iC60 RCD - range overview
(back to index)
Type AC
protection of:
general purpose power sockets
incandescent lighting
general appliances with rectifier/inverter
Type A
protection of:
appliances with rectifier
single-phase variable speed drives / inverters
Type SI
protection of appliances generating high frequency interferences (current peaks, harmonics)
installation in proximity of high powered switching devices
installation in circuits powered by UPS
installation in buildings protected by surge protection devices
protection of:
protection of:
4.1. RCD add-on (Residual Current Add-on) - Vigi - Type AC - Product selection table
(back to index)4.2. RCD add-on (Residual Current Add-on) - Vigi - Type A - Product selection table
(back to index)4.3. RCD add-on (Residual Current Add-on) - Vigi - Type SI - Product selection table
(back to index)Characteristics | ||||||||
---|---|---|---|---|---|---|---|---|
25A | 40A | 63A | ||||||
Standard | Standard | Standard | ||||||
Poles | IΔn = | 10mA | 30mA | 300mA | 30mA | 100mA | 30mA | 300mA |
2P | 10mA 25A SI-type |
30mA 25A SI-type |
300mA 25A SI-type |
30mA 63A SI-type |
100mA 63A SI-type |
30mA 63A SI-type |
300mA 63A SI-type |
|
3P | - | 30mA 25A SI-type |
300mA 25A SI-type |
30mA 63A SI-type |
- | 30mA 63A SI-type |
300mA 63A SI-type |
|
4P | - | 30mA 25A SI-type |
300mA 25A SI-type |
30mA 63A SI-type |
100mA 63A SI-type |
30mA 63A SI-type |
300mA 63A SI-type |
5. Accessories/auxiliaries: auxiliary contacts SD/OF, locking accessories, terminal covers - Product selection table
(back to index)Auxiliary contact blocks | Locking | Handles | Plug-in base | Safety and security | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Function | 1C/O (SPDT) |
1C/O (SPDT) |
2C/O (2xSPDT) |
device |
handle kit |
handle kit |
without handle |
of a breaker |
shield |
shields (splittable) |
terminal covers |
terminal covers |
barrier |
spacer |
Product | A9A26924 |
A9A26927 |
A9A26929 |
A9A26970 |
A9A27005 |
A9A27006 |
A9A27008 |
A9A27003 |
A9A26982 |
A9A26981 |
A9A26975 |
A9A26976 |
A9A27001 |
A9A27062 |
compatible with | MCB (iC60), MCB+RCD (iC60+Vigi), RCCB (iID) | MCB (iC60), MCB+RCD (iC60+Vigi), RCCB (iID) | MCB (iC60), MCB+RCD (iC60+Vigi), RCCB (iID) | MCB (iC60), RCCB (iID) ≤63A | RCD (Vigi iC60) | RCD (Vigi iC60) | MCB (iC60) | MCB (iC60), MCB+RCD (iC60+Vigi), RCCB (iID) | MCB (iC60), RCCB (iID) | MCB (iC60), MCB+RCD (iC60+Vigi), RCCB (iID) |
6. Control add-ons: Automatic reclosers, Remote control, closing / tripping coils
(back to index)Features
Acti 9 Reflex iC60 DIN rail integrated control circuit breaker offers absolute safety and enhanced continuity of service with:
- VisiSafe for entirely secure operation and maintenance operations on circuits.
- Class-2 insulation: permanent safety for operators and non-qualified personnel.
- VisiTrip for rapid detection of faulty outgoers and reduced intervention times.
- Direct interface with a PLC thanks to integrated electrical auxiliaries for maximum compatibility with Building Management Systems (BMS).
- Integrated padlocking facility offering maximum safety for maintenance operations.
- Add-on Residual Current Devices (RCDs) from the Acti 9 range, entirely immune to interference: enhanced continuity of service, particularly in polluted networks and environments.
- Integrated remote control with three modes of operation for maximum flexibility and upgradeability of the electrical installation.
With easy maintenance, the Acti 9 automatic recloser helps you to increase the availability of installations without supervision. In the case of unwanted tripping protection, installers can automatically re-close electrical circuits on unattended sites, making it ideal for use in a wide range of locations from banks and gas stations, to communication shelters and beyond.
- Choose from four different programs for iC60.
- Advance settings included such as a time delay before re-closing.
- Reinitialisation time delay also included.
- A maximum number of re-closing attempts.
- If fault is still present after maximum number is exceeded, device places itself in waiting for manual closing.
- Alternatively user can choose final remote closing.
- Completely bistable, meaning the state does not change should there be an electrical power outage.
Technical data
- Rated current: 10, 16, 25, 40 and 63 A
- Breaking capacity: 10 kA for the Reflex iC60 N version and 15 kA for the Reflex iC60 H version
- Tripping curves: B, C, D
- Compliance with standard IEC/EN 60947-2, certified by official national bodies
- Complete coordination with the RCDsof the Acti 9 range and the Compact NSX MCCBs
- Suitability for isolation in compliance with industrial standard IEC/EN 60947
- Voltage rating: up to 400 Vac, insulation voltage: 500 V
- Add-on residual current devices (optional): Vigi iC60 and Quick Vigi
- Integrated auxiliaries: potential-free contacts for status and operation (OF and SD)
- Auxiliaries (optional): 24/48V DC-AC power adapter
Benefits
Reflex iC60 is a unique concept that combines the following functions:
- Circuit protection against short-circuit currents
- Circuit protection against overload currents
- Isolation in compliance with industrial operation requirements
- Remote control by latched and/or impulse-type order
- Indication of Open/Closed and Fault status via potential-free contacts
- Interface for link with PLC or BMS (as per IEC 61131) - Mixing and typing of control orders via simplified configuration
- Absolute safety of circuit protection with VisiSafe,
- control mode flexibility,
- ease of installation in a control environment with direct interface to PLC or BMS,
- Greater continuity of service with VisiTrip,
- Easy to install with up to 50% less wiring, environmentally friendly with 100% recyclable and recoverable components
With ARA automatic reclosers:
- protection and control of electric lighting circuits in all industrial and commercial buildings and infrastructures
- protection and remote control of non-priority circuits as part of a load shedding process
- protection and remote control of most electrical loads with very few switching operations
- particularly suited to 230 Vac remote control and conventional signalling or via a very low voltage interface for linking with a PLC or BMS
Acti9 control add-ons - range overview
(back to index)
6.1. Coils / release
Undervoltage tripping coils iMN
Shunt trip coils iMX
Overvoltage tripping coils
6.2. Automatic reclosers ARA
ideal for automated restarting of critical loads
various functions and reclosing cycles
Ready for direct connection with 24Vdc automation circuits
6.3. Remote Control RCA
For remote closing of MCBs
Ready for direct connection with 24Vdc automation circuits
6.4. Bistable control Reflex
Allows remote closing and opening of MCBs and RCCBs
Bistable (impulse) or monostable (sustained) control signal
6.1. Tripping coils / releases - Product selection table
(back to index)Shunt trip coils / opening releases | Undervoltage trip coils / opening releases | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Function | Standard (MX) | with 1 aux. C/O / SPDT contact (MX+OF) | Standard (MN) | Delayed (MNs) | with external feeding (MNx) | ||||||||
Control voltage | 12-24Vac/dc | 48Vac/dc | 100-115Vac /110-130Vdc | 12-24Vac/dc | 48Vac/dc | 220-415Vac/dc | 24Vac/dc | 48Vac/dc | 115Vac (400Hz) | 220-240Vac | 220-240Vac | 220-240Vac | 380-415Vac |
Product | A9...26478 |
A9...26477 |
A9...26476 |
A9...26948 |
A9...26947 |
A9...26946 |
A9...27108 |
A9...26961 |
A9...26959 |
A9...26960 |
A9...26963 |
A9...26969 |
A9...26971 |
6.2. Automatic reclosers for MCBs and RCCBs (ARA) - Product selection table
(back to index)6.3. Remote control unit for MCBs (RCA) - Product selection table
(back to index)6.4 Bistable controls (Reflex iC60N / iC60H) - Product selection table
(back to index)6.4.1. Reflex iC60N / iC60H curve B
6.4.2. Reflex iC60N / iC60H curve C
(back to index)6.4.3. Reflex iC60N / iC60H curve D
(back to index)Characteristics | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
With Ti24 interface connector | With standard connector | ||||||||||||||
Reflex iC60N | Reflex iC60H | Reflex iC60N | |||||||||||||
10A | 16A | 25A | 40A | 63A | 10A | 16A | 25A | 40A | 10A | 16A | 25A | 40A | 63A | ||
2P | 10A 2P Ti24 D-curve |
16A 2P Ti24 D-curve |
25A 2P Ti24 D-curve |
- | - | 10A 2P Ti24 D-curve |
16A 2P Ti24 D-curve |
25A 2P Ti24 D-curve |
- | - | - | - | - | - | |
3P | 10A 3P Ti24 D-curve |
16A 3P Ti24 D-curve |
25A 3P Ti24 D-curve |
- | - | 10A 3P Ti24 D-curve |
16A 3P Ti24 D-curve |
25A 3P Ti24 D-curve |
- | - | - | - | - | - | |
4P | 10A 4P Ti24 D-curve |
16A 4P Ti24 D-curve |
25A 4P Ti24 D-curve |
- | - | 10A 4P Ti24 D-curve |
16A 4P Ti24 D-curve |
25A 4P Ti24 D-curve |
- | - | - | - | - | - |